13 research outputs found

    Inner-ear Augmented Metal Artifact Reduction with Simulation-based 3D Generative Adversarial Networks

    Get PDF
    International audienceMetal Artifacts creates often difficulties for a high-quality visual assessment of post-operative imaging in computed tomography (CT). A vast body of methods have been proposed to tackle this issue, but these methods were designed for regular CT scans and their performance is usually insufficient when imaging tiny implants. In the context of post-operative high-resolution CT imaging, we propose a 3D metal artifact reduction algorithm based on a generative adversarial neural network. It is based on the simulation of physically realistic CT metal artifacts created by cochlea implant electrodes on preoperative images. The generated images serve to train 3D generative adversarial networks for artifacts reduction. The proposed approach was assessed qualitatively and quantitatively on clinical conventional and cone-beam CT of cochlear implant postoperative images. These experiments show that the proposed method outperforms other general metal artifact reduction approaches

    Automating the multimodal analysis of musculoskeletal imaging in the presence of hip implants

    Get PDF
    In patients treated with hip arthroplasty, the muscular condition and presence of inflammatory reactions are assessed using magnetic resonance imaging (MRI). As MRI lacks contrast for bony structures, computed tomography (CT) is preferred for clinical evaluation of bone tissue and orthopaedic surgical planning. Combining the complementary information of MRI and CT could improve current clinical practice for diagnosis, monitoring and treatment planning. In particular, the different contrast of these modalities could help better quantify the presence of fatty infiltration to characterise muscular condition after hip replacement. In this thesis, I developed automated processing tools for the joint analysis of CT and MR images of patients with hip implants. In order to combine the multimodal information, a novel nonlinear registration algorithm was introduced, which imposes rigidity constraints on bony structures to ensure realistic deformation. I implemented and thoroughly validated a fully automated framework for the multimodal segmentation of healthy and pathological musculoskeletal structures, as well as implants. This framework combines the proposed registration algorithm with tailored image quality enhancement techniques and a multi-atlas-based segmentation approach, providing robustness against the large population anatomical variability and the presence of noise and artefacts in the images. The automation of muscle segmentation enabled the derivation of a measure of fatty infiltration, the Intramuscular Fat Fraction, useful to characterise the presence of muscle atrophy. The proposed imaging biomarker was shown to strongly correlate with the atrophy radiological score currently used in clinical practice. Finally, a preliminary work on multimodal metal artefact reduction, using an unsupervised deep learning strategy, showed promise for improving the postprocessing of CT and MR images heavily corrupted by metal artefact. This work represents a step forward towards the automation of image analysis in hip arthroplasty, supporting and quantitatively informing the decision-making process about patient’s management

    Integrated navigation and visualisation for skull base surgery

    Get PDF
    Skull base surgery involves the management of tumours located on the underside of the brain and the base of the skull. Skull base tumours are intricately associated with several critical neurovascular structures making surgery challenging and high risk. Vestibular schwannoma (VS) is a benign nerve sheath tumour arising from one of the vestibular nerves and is the commonest pathology encountered in skull base surgery. The goal of modern VS surgery is maximal tumour removal whilst preserving neurological function and maintaining quality of life but despite advanced neurosurgical techniques, facial nerve paralysis remains a potentially devastating complication of this surgery. This thesis describes the development and integration of various advanced navigation and visualisation techniques to increase the precision and accuracy of skull base surgery. A novel Diffusion Magnetic Resonance Imaging (dMRI) acquisition and processing protocol for imaging the facial nerve in patients with VS was developed to improve delineation of facial nerve preoperatively. An automated Artificial Intelligence (AI)-based framework was developed to segment VS from MRI scans. A user-friendly navigation system capable of integrating dMRI and tractography of the facial nerve, 3D tumour segmentation and intraoperative 3D ultrasound was developed and validated using an anatomically-realistic acoustic phantom model of a head including the skull, brain and VS. The optical properties of five types of human brain tumour (meningioma, pituitary adenoma, schwannoma, low- and high-grade glioma) and nine different types of healthy brain tissue were examined across a wavelength spectrum of 400 nm to 800 nm in order to inform the development of an Intraoperative Hypserpectral Imaging (iHSI) system. Finally, functional and technical requirements of an iHSI were established and a prototype system was developed and tested in a first-in-patient study

    Proceedings of the 19th Sound and Music Computing Conference

    Get PDF
    Proceedings of the 19th Sound and Music Computing Conference - June 5-12, 2022 - Saint-Étienne (France). https://smc22.grame.f

    MS FT-2-2 7 Orthogonal polynomials and quadrature: Theory, computation, and applications

    Get PDF
    Quadrature rules find many applications in science and engineering. Their analysis is a classical area of applied mathematics and continues to attract considerable attention. This seminar brings together speakers with expertise in a large variety of quadrature rules. It is the aim of the seminar to provide an overview of recent developments in the analysis of quadrature rules. The computation of error estimates and novel applications also are described

    Generalized averaged Gaussian quadrature and applications

    Get PDF
    A simple numerical method for constructing the optimal generalized averaged Gaussian quadrature formulas will be presented. These formulas exist in many cases in which real positive GaussKronrod formulas do not exist, and can be used as an adequate alternative in order to estimate the error of a Gaussian rule. We also investigate the conditions under which the optimal averaged Gaussian quadrature formulas and their truncated variants are internal
    corecore