Automatic calibration of space based manipulators and mechanisms
Four tasks in manipulator kinematic calibration are summarized. Calibration of a seven degree of freedom manipulator was simulated. A calibration model is presented that can be applied on a closed-loop robot. It is an expansion of open-loop kinematic calibration algorithms subject to constraints. A closed-loop robot with a five-bar linkage transmission was tested. Results show that the algorithm converges within a few iterations. The concept of model differences is formalized. Differences are categorized as structural and numerical, with emphasis on the structural. The work demonstrates that geometric manipulators can be visualized as points in a vector space with the dimension of the space depending solely on the number and type of manipulator joint. Visualizing parameters in a kinematic model as the coordinates locating the manipulator in vector space enables a standard evaluation of the models. Key results include a derivation of the maximum number of parameters necessary for models, a formal discussion on the inclusion of extra parameters, and a method to predetermine a minimum model structure for a kinematic manipulator. A technique is presented that enables single point sensors to gather sufficient information to complete a calibration
Design of Calibration Experiments for Identification of Manipulator Elastostatic Parameters
The paper is devoted to the elastostatic calibration of industrial robots,
which is used for precise machining of large-dimensional parts made of
composite materials. In this technological process, the interaction between the
robot and the workpiece causes essential elastic deflections of the manipulator
components that should be compensated by the robot controller using relevant
elastostatic model of this mechanism. To estimate parameters of this model, an
advanced calibration technique is applied that is based on the non-linear
experiment design theory, which is adopted for this particular application. In
contrast to previous works, it is proposed a concept of the user-defined
test-pose, which is used to evaluate the calibration experiments quality. In
the frame of this concept, the related optimization problem is defined and
numerical routines are developed, which allow generating optimal set of
manipulator configurations and corresponding forces/torques for a given number
of the calibration experiments. Some specific kinematic constraints are also
taken into account, which insure feasibility of calibration experiments for the
obtained configurations and allow avoiding collision between the robotic
manipulator and the measurement equipment. The efficiency of the developed
technique is illustrated by an application example that deals with elastostatic
calibration of the serial manipulator used for robot-based machining.Comment: arXiv admin note: substantial text overlap with arXiv:1211.573
Design of Calibration Experiments for Identification of Manipulator Elastostatic Parameters
International audienceThe paper is devoted to the elastostatic calibration of industrial robots, which is used for precise machining of large-dimensional parts made of composite materials. In this technological process, the interaction between the robot and the workpiece causes essential elastic deflections of the manipulator components that should be compensated by the robot controller using relevant elastostatic model of this mechanism. To estimate parameters of this model, an advanced calibration technique is applied that is based on the non-linear experiment design theory, which is adopted for this particular application. In contrast to previous works, it is proposed a concept of the user-defined test-pose, which is used to evaluate the calibration experiments quality. In the frame of this concept, the related optimization problem is defined and numerical routines are developed, which allow generating optimal set of manipulator configurations and corresponding forces/torques for a given number of the calibration experiments. Some specific kinematic constraints are also taken into account, which insure feasibility of calibration experiments for the obtained configurations and allow avoiding collision between the robotic manipulator and the measurement equipment. The efficiency of the developed technique is illustrated by an application example that deals with elastostatic calibration of the serial manipulator used for robot-based machining
Compliance error compensation technique for parallel robots composed of non-perfect serial chains
The paper presents the compliance errors compensation technique for
over-constrained parallel manipulators under external and internal loadings.
This technique is based on the non-linear stiffness modeling which is able to
take into account the influence of non-perfect geometry of serial chains caused
by manufacturing errors. Within the developed technique, the deviation
compensation reduces to an adjustment of a target trajectory that is modified
in the off-line mode. The advantages and practical significance of the proposed
technique are illustrated by an example that deals with groove milling by the
Orthoglide manipulator that considers different locations of the workpiece. It
is also demonstrated that the impact of the compliance errors and the errors
caused by inaccuracy in serial chains cannot be taken into account using the
superposition principle.Comment: arXiv admin note: text overlap with arXiv:1204.175
Kinematic calibration of Orthoglide-type mechanisms from observation of parallel leg motions
The paper proposes a new calibration method for parallel manipulators that
allows efficient identification of the joint offsets using observations of the
manipulator leg parallelism with respect to the base surface. The method
employs a simple and low-cost measuring system, which evaluates deviation of
the leg location during motions that are assumed to preserve the leg
parallelism for the nominal values of the manipulator parameters. Using the
measured deviations, the developed algorithm estimates the joint offsets that
are treated as the most essential parameters to be identified. The validity of
the proposed calibration method and efficiency of the developed numerical
algorithms are confirmed by experimental results. The sensitivity of the
measurement methods and the calibration accuracy are also studied
Design of Experiments for Calibration of Planar Anthropomorphic Manipulators
The paper presents a novel technique for the design of optimal calibration
experiments for a planar anthropomorphic manipulator with n degrees of freedom.
Proposed approach for selection of manipulator configurations allows
essentially improving calibration accuracy and reducing parameter
identification errors. The results are illustrated by application examples that
deal with typical anthropomorphic manipulators.Comment: Advanced Intelligent Mechatronics (AIM), 2011 IEEE/ASME International
Conference on, Budapest : Hungary (2011
Encoderless Gimbal Calibration of Dynamic Multi-Camera Clusters
Dynamic Camera Clusters (DCCs) are multi-camera systems where one or more
cameras are mounted on actuated mechanisms such as a gimbal. Existing methods
for DCC calibration rely on joint angle measurements to resolve the
time-varying transformation between the dynamic and static camera. This
information is usually provided by motor encoders, however, joint angle
measurements are not always readily available on off-the-shelf mechanisms. In
this paper, we present an encoderless approach for DCC calibration which
simultaneously estimates the kinematic parameters of the transformation chain
as well as the unknown joint angles. We also demonstrate the integration of an
encoderless gimbal mechanism with a state-of-the art VIO algorithm, and show
the extensions required in order to perform simultaneous online estimation of
the joint angles and vehicle localization state. The proposed calibration
approach is validated both in simulation and on a physical DCC composed of a
2-DOF gimbal mounted on a UAV. Finally, we show the experimental results of the
calibrated mechanism integrated into the OKVIS VIO package, and demonstrate
successful online joint angle estimation while maintaining localization
accuracy that is comparable to a standard static multi-camera configuration.Comment: ICRA 201
Generic Techniques for the Calibration of Robots with Application of the 3-D Fixtures and Statistical Technique on the PUMA 500 and ARID Robots
A relatively simple, inexpensive, and generic technique that could be used in both laboratories and some operation site environments is introduced at the Robotics Applications and Development Laboratory (RADL) at Kennedy Space Center (KSC). In addition, this report gives a detailed explanation of the set up procedure, data collection, and analysis using this new technique that was developed at the State University of New York at Farmingdale. The technique was used to evaluate the repeatability, accuracy, and overshoot of the Unimate Industrial Robot, PUMA 500. The data were statistically analyzed to provide an insight into the performance of the systems and components of the robot. Also, the same technique was used to check the forward kinematics against the inverse kinematics of RADL's PUMA robot. Recommendations were made for RADL to use this technique for laboratory calibration of the currently existing robots such as the ASEA, high speed controller, Automated Radiator Inspection Device (ARID) etc. Also, recommendations were made to develop and establish other calibration techniques that will be more suitable for site calibration environment and robot certification
- …