543 research outputs found

    Iterative Poisson-Gaussian Noise Parametric Estimation for Blind Image Denoising

    Get PDF
    International audienceThis paper deals with noise parameter estimation from a single im- age under Poisson-Gaussian noise statistics. The problem is formu- lated within a mixed discrete-continuous optimization framework. The proposed approach jointly estimates the signal of interest and the noise parameters. This is achieved by introducing an adjustable reg- ularization term inside an optimized criterion, together with a data fidelity error measure. The optimal solution is sought iteratively by alternating the minimization of a label field and of a noise param- eter vector. Noise parameters are updated at each iteration using an Expectation-Maximization approach. The proposed algorithm is inspired from a spatial regularization approach for vector quantiza- tion. We illustrate the usefulness of our approach on macroconfocal images. The identified noise parameters are applied to a denoising algorithm, so yielding a fully automatic denoising scheme

    Recent Progress in Image Deblurring

    Full text link
    This paper comprehensively reviews the recent development of image deblurring, including non-blind/blind, spatially invariant/variant deblurring techniques. Indeed, these techniques share the same objective of inferring a latent sharp image from one or several corresponding blurry images, while the blind deblurring techniques are also required to derive an accurate blur kernel. Considering the critical role of image restoration in modern imaging systems to provide high-quality images under complex environments such as motion, undesirable lighting conditions, and imperfect system components, image deblurring has attracted growing attention in recent years. From the viewpoint of how to handle the ill-posedness which is a crucial issue in deblurring tasks, existing methods can be grouped into five categories: Bayesian inference framework, variational methods, sparse representation-based methods, homography-based modeling, and region-based methods. In spite of achieving a certain level of development, image deblurring, especially the blind case, is limited in its success by complex application conditions which make the blur kernel hard to obtain and be spatially variant. We provide a holistic understanding and deep insight into image deblurring in this review. An analysis of the empirical evidence for representative methods, practical issues, as well as a discussion of promising future directions are also presented.Comment: 53 pages, 17 figure

    Non-parametric PSF estimation from celestial transit solar images using blind deconvolution

    Get PDF
    Context: Characterization of instrumental effects in astronomical imaging is important in order to extract accurate physical information from the observations. The measured image in a real optical instrument is usually represented by the convolution of an ideal image with a Point Spread Function (PSF). Additionally, the image acquisition process is also contaminated by other sources of noise (read-out, photon-counting). The problem of estimating both the PSF and a denoised image is called blind deconvolution and is ill-posed. Aims: We propose a blind deconvolution scheme that relies on image regularization. Contrarily to most methods presented in the literature, our method does not assume a parametric model of the PSF and can thus be applied to any telescope. Methods: Our scheme uses a wavelet analysis prior model on the image and weak assumptions on the PSF. We use observations from a celestial transit, where the occulting body can be assumed to be a black disk. These constraints allow us to retain meaningful solutions for the filter and the image, eliminating trivial, translated and interchanged solutions. Under an additive Gaussian noise assumption, they also enforce noise canceling and avoid reconstruction artifacts by promoting the whiteness of the residual between the blurred observations and the cleaned data. Results: Our method is applied to synthetic and experimental data. The PSF is estimated for the SECCHI/EUVI instrument using the 2007 Lunar transit, and for SDO/AIA using the 2012 Venus transit. Results show that the proposed non-parametric blind deconvolution method is able to estimate the core of the PSF with a similar quality to parametric methods proposed in the literature. We also show that, if these parametric estimations are incorporated in the acquisition model, the resulting PSF outperforms both the parametric and non-parametric methods.Comment: 31 pages, 47 figure

    ParaPET: non-invasive deep learning method for direct parametric brain PET reconstruction using histoimages.

    Get PDF
    BACKGROUND The indirect method for generating parametric images in positron emission tomography (PET) involves the acquisition and reconstruction of dynamic images and temporal modelling of tissue activity given a measured arterial input function. This approach is not robust, as noise in each dynamic image leads to a degradation in parameter estimation. Direct methods incorporate into the image reconstruction step both the kinetic and noise models, leading to improved parametric images. These methods require extensive computational time and large computing resources. Machine learning methods have demonstrated significant potential in overcoming these challenges. But they are limited by the requirement of a paired training dataset. A further challenge within the existing framework is the use of state-of-the-art arterial input function estimation via temporal arterial blood sampling, which is an invasive procedure, or an additional magnetic resonance imaging (MRI) scan for selecting a region where arterial blood signal can be measured from the PET image. We propose a novel machine learning approach for reconstructing high-quality parametric brain images from histoimages produced from time-of-flight PET data without requiring invasive arterial sampling, an MRI scan, or paired training data from standard field-of-view scanners. RESULT The proposed is tested on a simulated phantom and five oncological subjects undergoing an 18F-FDG-PET scan of the brain using Siemens Biograph Vision Quadra. Kinetic parameters set in the brain phantom correlated strongly with the estimated parameters (K1, k2 and k3, Pearson correlation coefficient of 0.91, 0.92 and 0.93) and a mean squared error of less than 0.0004. In addition, our method significantly outperforms (p < 0.05, paired t-test) the conventional nonlinear least squares method in terms of contrast-to-noise ratio. At last, the proposed method was found to be 37% faster than the conventional method. CONCLUSION We proposed a direct non-invasive DL-based reconstruction method and produced high-quality parametric maps of the brain. The use of histoimages holds promising potential for enhancing the estimation of parametric images, an area that has not been extensively explored thus far. The proposed method can be applied to subject-specific dynamic PET data alone

    Comparison of Image Restoration Methods for Lunar Epithermal Neutron Emission Mapping

    Get PDF
    Orbital measurements of neutrons by the Lunar Exploring Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter are being used to quantify the spatial distribution of near surface hydrogen (H). Inferred H concentration maps have low signal-to-noise (SN) and image restoration (IR) techniques are being studied to enhance results. A single-blind. two-phase study is described in which four teams of researchers independently developed image restoration techniques optimized for LEND data. Synthetic lunar epithermal neutron emission maps were derived from LEND simulations. These data were used as ground truth to determine the relative quantitative performance of the IR methods vs. a default denoising (smoothing) technique. We review and used factors influencing orbital remote sensing of neutrons emitted from the lunar surface to develop a database of synthetic "true" maps for performance evaluation. A prior independent training phase was implemented for each technique to assure methods were optimized before the blind trial. Method performance was determined using several regional root-mean-square error metrics specific to epithermal signals of interest. Results indicate unbiased IR methods realize only small signal gains in most of the tested metrics. This suggests other physically based modeling assumptions are required to produce appreciable signal gains in similar low SN IR applications
    • …
    corecore