Novel hybrid extraction systems for fetal heart rate variability monitoring based on non-invasive fetal electrocardiogram
This study focuses on the design, implementation and subsequent verification of a new type of hybrid extraction system for noninvasive fetal electrocardiogram (NI-fECG) processing. The system designed combines the advantages of individual adaptive and non-adaptive algorithms. The pilot study reviews two innovative hybrid systems called ICA-ANFIS-WT and ICA-RLS-WT. This is a combination of independent component analysis (ICA), adaptive neuro-fuzzy inference system (ANFIS) algorithm or recursive least squares (RLS) algorithm and wavelet transform (WT) algorithm. The study was conducted on clinical practice data (extended ADFECGDB database and Physionet Challenge 2013 database) from the perspective of non-invasive fetal heart rate variability monitoring based on the determination of the overall probability of correct detection (ACC), sensitivity (SE), positive predictive value (PPV) and harmonic mean between SE and PPV (F1). System functionality was verified against a relevant reference obtained by an invasive way using a scalp electrode (ADFECGDB database), or relevant reference obtained by annotations (Physionet Challenge 2013 database). The study showed that ICA-RLS-WT hybrid system achieve better results than ICA-ANFIS-WT. During experiment on ADFECGDB database, the ICA-RLS-WT hybrid system reached ACC > 80 % on 9 recordings out of 12 and the ICA-ANFIS-WT hybrid system reached ACC > 80 % only on 6 recordings out of 12. During experiment on Physionet Challenge 2013 database the ICA-RLS-WT hybrid system reached ACC > 80 % on 13 recordings out of 25 and the ICA-ANFIS-WT hybrid system reached ACC > 80 % only on 7 recordings out of 25. Both hybrid systems achieve provably better results than the individual algorithms tested in previous studies.Web of Science713178413175
Antepartum Fetal Monitoring through a Wearable System and a Mobile Application
Prenatal monitoring of Fetal Heart Rate (FHR) is crucial for the prevention of fetal pathologies and unfavorable deliveries. However, the most commonly used Cardiotocographic exam can be performed only in hospital-like structures and requires the supervision of expert personnel. For this reason, a wearable system able to continuously monitor FHR would be a noticeable step towards a personalized and remote pregnancy care. Thanks to textile electrodes, miniaturized electronics, and smart devices like smartphones and tablets, we developed a wearable integrated system for everyday fetal monitoring during the last weeks of pregnancy. Pregnant women at home can use it without the need for any external support by clinicians. The transmission of FHR to a specialized medical center allows its remote analysis, exploiting advanced algorithms running on high-performance hardware able to obtain the best classification of the fetal condition. The system has been tested on a limited set of pregnant women whose fetal electrocardiogram recordings were acquired and classified, yielding an overall score for both accuracy and sensitivity over 90%. This novel approach can open a new perspective on the continuous monitoring of fetus development by enhancing the performance of regular examinations, making treatments really personalized, and reducing hospitalization or ambulatory visits. Keywords: tele-monitoring; wearable devices; fetal heart rate; telemedicin
The human ECG - nonlinear deterministic versus stochastic aspects
We discuss aspects of randomness and of determinism in electrocardiographic
signals. In particular, we take a critical look at attempts to apply methods of
nonlinear time series analysis derived from the theory of deterministic
dynamical systems. We will argue that deterministic chaos is not a likely
explanation for the short time variablity of the inter-beat interval times,
except for certain pathologies. Conversely, densely sampled full ECG recordings
possess properties typical of deterministic signals. In the latter case,
methods of deterministic nonlinear time series analysis can yield new insights.Comment: 6 pages, 9 PS figure
Detection of atrial fibrillation episodes in long-term heart rhythm signals using a support vector machine
Atrial fibrillation (AF) is a serious heart arrhythmia leading to a significant increase of the risk for occurrence of ischemic stroke. Clinically, the AF episode is recognized in an electrocardiogram. However, detection of asymptomatic AF, which requires a long-term monitoring, is more efficient when based on irregularity of beat-to-beat intervals estimated by the heart rate (HR) features. Automated classification of heartbeats into AF and non-AF by means of the Lagrangian Support Vector Machine has been proposed. The classifier input vector consisted of sixteen features, including four coefficients very sensitive to beat-to-beat heart changes, taken from the fetal heart rate analysis in perinatal medicine. Effectiveness of the proposed classifier has been verified on the MIT-BIH Atrial Fibrillation Database. Designing of the LSVM classifier using very large number of feature vectors requires extreme computational efforts. Therefore, an original approach has been proposed to determine a training set of the smallest possible size that still would guarantee a high quality of AF detection. It enables to obtain satisfactory results using only 1.39% of all heartbeats as the training data. Post-processing stage based on aggregation of classified heartbeats into AF episodes has been applied to provide more reliable information on patient risk. Results obtained during the testing phase showed the sensitivity of 98.94%, positive predictive value of 98.39%, and classification accuracy of 98.86%.Web of Science203art. no. 76
Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations
Monitoring fetal heart rate (FHR) variability plays a fundamental role in fetal state assessment. Reliable FHR signal can be obtained from an invasive direct fetal electrocardiogram (FECG), but this is limited to labour. Alternative abdominal (indirect) FECG signals can be recorded during pregnancy and labour. Quality, however, is much lower and the maternal heart and uterine contractions provide sources of interference. Here, we present ten twenty-minute pregnancy signals and 12 five-minute labour signals. Abdominal FECG and reference direct FECG were recorded simultaneously during labour. Reference pregnancy signal data came from an automated detector and were corrected by clinical experts. The resulting dataset exhibits a large variety of interferences and clinically significant FHR patterns. We thus provide the scientific community with access to bioelectrical fetal heart activity signals that may enable the development of new methods for FECG signals analysis, and may ultimately advance the use and accuracy of abdominal electrocardiography methods.Web of Science71art. no. 20
Detection and Processing Techniques of FECG Signal for Fetal Monitoring
Fetal electrocardiogram (FECG) signal contains potentially precise information that could assist clinicians in making more appropriate and timely decisions during labor. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies are becoming very important requirements in fetal monitoring. The purpose of this review paper is to illustrate the various methodologies and developed algorithms on FECG signal detection and analysis to provide efficient and effective ways of understanding the FECG signal and its nature for fetal monitoring. A comparative study has been carried out to show the performance and accuracy of various methods of FECG signal analysis for fetal monitoring. Finally, this paper further focused some of the hardware implementations using electrical signals for monitoring the fetal heart rate. This paper opens up a passage for researchers, physicians, and end users to advocate an excellent understanding of FECG signal and its analysis procedures for fetal heart rate monitoring system
Deep Learning in Cardiology
The medical field is creating large amount of data that physicians are unable
to decipher and use efficiently. Moreover, rule-based expert systems are
inefficient in solving complicated medical tasks or for creating insights using
big data. Deep learning has emerged as a more accurate and effective technology
in a wide range of medical problems such as diagnosis, prediction and
intervention. Deep learning is a representation learning method that consists
of layers that transform the data non-linearly, thus, revealing hierarchical
relationships and structures. In this review we survey deep learning
application papers that use structured data, signal and imaging modalities from
cardiology. We discuss the advantages and limitations of applying deep learning
in cardiology that also apply in medicine in general, while proposing certain
directions as the most viable for clinical use.Comment: 27 pages, 2 figures, 10 table
Development of a Novel Dataset and Tools for Non-Invasive Fetal Electrocardiography Research
This PhD thesis presents the development of a novel open multi-modal dataset
for advanced studies on fetal cardiological assessment, along with a set of signal
processing tools for its exploitation. The Non-Invasive Fetal Electrocardiography
(ECG) Analysis (NInFEA) dataset features multi-channel electrophysiological
recordings characterized by high sampling frequency and digital resolution,
maternal respiration signal, synchronized fetal trans-abdominal pulsed-wave
Doppler (PWD) recordings and clinical annotations provided by expert
clinicians at the time of the signal collection. To the best of our knowledge,
there are no similar dataset available.
The signal processing tools targeted both the PWD and the non-invasive
fetal ECG, exploiting the recorded dataset. About the former, the study focuses
on the processing aimed at the preparation of the signal for the automatic
measurement of relevant morphological features, already adopted in the
clinical practice for cardiac assessment. To this aim, a relevant step is the automatic
identification of the complete and measurable cardiac cycles in the PWD
videos: a rigorous methodology was deployed for the analysis of the different
processing steps involved in the automatic delineation of the PWD envelope,
then implementing different approaches for the supervised classification of the
cardiac cycles, discriminating between complete and measurable vs. malformed
or incomplete ones. Finally, preliminary measurement algorithms were also developed
in order to extract clinically relevant parameters from the PWD.
About the fetal ECG, this thesis concentrated on the systematic analysis of
the adaptive filters performance for non-invasive fetal ECG extraction processing,
identified as the reference tool throughout the thesis. Then, two studies
are reported: one on the wavelet-based denoising of the extracted fetal ECG
and another one on the fetal ECG quality assessment from the analysis of the
raw abdominal recordings.
Overall, the thesis represents an important milestone in the field, by promoting
the open-data approach and introducing automated analysis tools that
could be easily integrated in future medical devices
- …