    Development of an augmented reality guided computer assisted orthopaedic surgery system

    Get PDF
    Previously held under moratorium from 1st December 2016 until 1st December 2021.This body of work documents the developed of a proof of concept augmented reality guided computer assisted orthopaedic surgery system – ARgCAOS. After initial investigation a visible-spectrum single camera tool-mounted tracking system based upon fiducial planar markers was implemented. The use of visible-spectrum cameras, as opposed to the infra-red cameras typically used by surgical tracking systems, allowed the captured image to be streamed to a display in an intelligible fashion. The tracking information defined the location of physical objects relative to the camera. Therefore, this information allowed virtual models to be overlaid onto the camera image. This produced a convincing augmented experience, whereby the virtual objects appeared to be within the physical world, moving with both the camera and markers as expected of physical objects. Analysis of the first generation system identified both accuracy and graphical inadequacies, prompting the development of a second generation system. This too was based upon a tool-mounted fiducial marker system, and improved performance to near-millimetre probing accuracy. A resection system was incorporated into the system, and utilising the tracking information controlled resection was performed, producing sub-millimetre accuracies. Several complications resulted from the tool-mounted approach. Therefore, a third generation system was developed. This final generation deployed a stereoscopic visible-spectrum camera system affixed to a head-mounted display worn by the user. The system allowed the augmentation of the natural view of the user, providing convincing and immersive three dimensional augmented guidance, with probing and resection accuracies of 0.55±0.04 and 0.34±0.04 mm, respectively.This body of work documents the developed of a proof of concept augmented reality guided computer assisted orthopaedic surgery system – ARgCAOS. After initial investigation a visible-spectrum single camera tool-mounted tracking system based upon fiducial planar markers was implemented. The use of visible-spectrum cameras, as opposed to the infra-red cameras typically used by surgical tracking systems, allowed the captured image to be streamed to a display in an intelligible fashion. The tracking information defined the location of physical objects relative to the camera. Therefore, this information allowed virtual models to be overlaid onto the camera image. This produced a convincing augmented experience, whereby the virtual objects appeared to be within the physical world, moving with both the camera and markers as expected of physical objects. Analysis of the first generation system identified both accuracy and graphical inadequacies, prompting the development of a second generation system. This too was based upon a tool-mounted fiducial marker system, and improved performance to near-millimetre probing accuracy. A resection system was incorporated into the system, and utilising the tracking information controlled resection was performed, producing sub-millimetre accuracies. Several complications resulted from the tool-mounted approach. Therefore, a third generation system was developed. This final generation deployed a stereoscopic visible-spectrum camera system affixed to a head-mounted display worn by the user. The system allowed the augmentation of the natural view of the user, providing convincing and immersive three dimensional augmented guidance, with probing and resection accuracies of 0.55±0.04 and 0.34±0.04 mm, respectively

    DYNAMIC MEASUREMENT OF THREE-DIMENSIONAL MOTION FROM SINGLE-PERSPECTIVE TWO-DIMENSIONAL RADIOGRAPHIC PROJECTIONS

    Get PDF
    The digital evolution of the x-ray imaging modality has spurred the development of numerous clinical and research tools. This work focuses on the design, development, and validation of dynamic radiographic imaging and registration techniques to address two distinct medical applications: tracking during image-guided interventions, and the measurement of musculoskeletal joint kinematics. Fluoroscopy is widely employed to provide intra-procedural image-guidance. However, its planar images provide limited information about the location of surgical tools and targets in three-dimensional space. To address this limitation, registration techniques, which extract three-dimensional tracking and image-guidance information from planar images, were developed and validated in vitro. The ability to accurately measure joint kinematics in vivo is an important tool in studying both normal joint function and pathologies associated with injury and disease, however it still remains a clinical challenge. A technique to measure joint kinematics from single-perspective x-ray projections was developed and validated in vitro, using clinically available radiography equipmen

    Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review

    Get PDF
    Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519

    The Effect of Robotic Technology on Perioperative Outcomes in Total Knee Arthroplasty

    Get PDF
    Introduction Robotic technology has recently regained momentum in total knee arthroplasty (TKA) but the effects of this technology on accuracy of implant positioning, intraoperative soft tissue injury and postoperative functional rehabilitation remain unknown. The objectives of this research thesis were to compare a comprehensive range of radiological objectives and perioperative outcomes in conventional jig-based TKA versus robotic-arm assisted TKA, and use optical motion capture technology to quantify the effects of anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) resection on knee biomechanics. Methods A series of prospective cohort studies were undertaken in patients with established knee osteoarthritis undergoing primary conventional jig-based TKA versus robotic-arm assisted TKA. Predefined radiological and perioperative study outcomes were recorded by independent observers. Optical motion capture technology during robotic TKA was used to quantify the effects of ACL and PCL resection on knee biomechanics. Results Robotic-arm assisted TKA was associated with improved accuracy of implant positioning, reduced periarticular soft tissue injury, decreased bone trauma, improved postoperative functional rehabilitation, and reduced early systemic inflammatory response compared to conventional jig-based TKA. The Macroscopic Soft Tissue Injury (MASTI) classification system was developed and validated for grading intraoperative periarticular soft tissue injury and bone trauma during TKA. ACL resection created flexion-extension mismatch by increasing the extension gap more than the flexion gap, whilst PCL resection increased the flexion gap proportionally more than the extension gap and created mediolateral laxity in knee flexion but not in extension. Conclusion Robotic-arm assisted TKA was associated with increased accuracy of implant positioning, reduced iatrogenic soft tissue injury, and improved functional rehabilitation compared to conventional jig-based TKA. ACL and PCL resections created unique changes in knee biomechanics that affected flexion-extension gaps and mediolateral soft tissue tension during TKA. On the basis of this thesis, further clinical trials have been established to determine the long-term clinical significance of these findings

    Impact of Ear Occlusion on In-Ear Sounds Generated by Intra-oral Behaviors

    Get PDF
    We conducted a case study with one volunteer and a recording setup to detect sounds induced by the actions: jaw clenching, tooth grinding, reading, eating, and drinking. The setup consisted of two in-ear microphones, where the left ear was semi-occluded with a commercially available earpiece and the right ear was occluded with a mouldable silicon ear piece. Investigations in the time and frequency domains demonstrated that for behaviors such as eating, tooth grinding, and reading, sounds could be recorded with both sensors. For jaw clenching, however, occluding the ear with a mouldable piece was necessary to enable its detection. This can be attributed to the fact that the mouldable ear piece sealed the ear canal and isolated it from the environment, resulting in a detectable change in pressure. In conclusion, our work suggests that detecting behaviors such as eating, grinding, reading with a semi-occluded ear is possible, whereas, behaviors such as clenching require the complete occlusion of the ear if the activity should be easily detectable. Nevertheless, the latter approach may limit real-world applicability because it hinders the hearing capabilities.</p

    A clinical review of robotic navigation in total knee arthroplasty: historical systems to modern design.

    Get PDF
    Robotic-assisted total knee arthroplasty (RA-TKA) has shown improved reproducibility and precision in mechanical alignment restoration, with improvement in early functional outcomes and 90-day episode of care cost savings compared to conventional TKA in some studies. However, its value is still to be determined.Current studies of RA-TKA systems are limited by short-term follow-up and significant heterogeneity of the available systems.In today\u27s paradigm shift towards an increased emphasis on quality of care while curtailing costs, providing value-based care is the primary goal for healthcare systems and clinicians. As robotic technology continues to develop, longer-term studies evaluating implant survivorship and complications will determine whether the initial capital is offset by improved outcomes.Future studies will have to determine the value of RA-TKA based on longer-term survivorships, patient-reported outcome measures, functional outcomes, and patient satisfaction measures

    Design and Evaluation of a Contact-Free Interface for Minimally Invasive Robotics Assisted Surgery

    Get PDF
    Robotic-assisted minimally invasive surgery (RAMIS) is becoming increasingly more common for many surgical procedures. These minimally invasive techniques offer the benefit of reduced patient recovery time, mortality and scarring compared to traditional open surgery. Teleoperated procedures have the added advantage of increased visualization, and enhanced accuracy for the surgeon through tremor filtering and scaling down hand motions. There are however still limitations in these techniques preventing the widespread growth of the technology. In RAMIS, the surgeon is limited in their movement by the operating console or master device, and the cost of robotic surgery is often too high to justify for many procedures. Sterility issues arise as well, as the surgeon must be in contact with the master device, preventing a smooth transition between traditional and robotic modes of surgery. This thesis outlines the design and analysis of a novel method of interaction with the da Vinci Surgical Robot. Using the da Vinci Research Kit (DVRK), an open source research platform for the da Vinci robot, an interface was developed for controlling the robotic arms with the Leap Motion Controller. This small device uses infrared LEDs and two cameras to detect the 3D positions of the hand and fingers. This data from the hands is mapped to the da Vinci surgical tools in real time, providing the surgeon with an intuitive method of controlling the instruments. An analysis of the tracking workspace is provided, to give a solution to occlusion issues. Multiple sensors are fused together in order to increase the range of trackable motion over a single sensor. Additional work involves replacing the current viewing screen with a virtual reality (VR) headset (Oculus Rift), to provide the surgeon with a stereoscopic 3D view of the surgical site without the need for a large monitor. The headset also provides the user with a more intuitive and natural method of positioning the camera during surgery, using the natural motions of the head. The large master console of the da Vinci system has been replaced with an inexpensive vision based tracking system, and VR headset, allowing the surgeon to operate the da Vinci Surgical Robot with more natural movements for the user. A preliminary evaluation of the system is provided, with recommendations for future work

    Computer assistance in orthopaedic surgery

    Get PDF

    Robotic Simulation of Disc Arthroplasty Surgery: Influence of Surgical Placement on Motion Segment Dynamics

    Get PDF
    A variety of total disc replacement (TDR) designs exist for the treatment of disc pathologies. A key design parameter for a constrained ball and socket device is the location of the fixed center of rotation (COR). A previous study demonstrated that intact motion segment unit (MSU) mechanics and range of motion (ROM) were sensitive to the location of a prescribed sagittal plane rotational axis. Mal-alignment between the implant COR and the COR of the MSU may lead to an overloaded or over constrained condition. Two paradigms exist for the placement of a fixed COR TDR device relative to MSU anatomy: positioning the implant midline or posterior to midline. Presently, there are no data to indicate which paradigm may lead to better biomechanical/clinical outcome. This research attempts to evaluate changes in MSU mechanics and ROM as a result of variations in the size and placement of a simulated ball and socket TDR, like the ProDisc-L lumbar disc prosthesis. Six human cadaveric lumbar MSUs, L4-L5, were tested in flexion/extension using the Spine Robot to an end load limit of 8Nm. A fixed axis protocol was used to impose a pure rotation about a desired anatomical location. The Spine Robot was programmed to rotate the MSU about the COR of the implant. Subsequently, with the MSU held rigid, the implant was removed and rotation about the implant’s COR was repeated. Thereafter, simulated CORs were tested in different anatomical locations as defined by a customized grid pattern. The grid pattern consisted of 8 CORs which simulated the placement of a medium and large size constrained ball and socket device. Measurements of shear forces along the disc plane, axial force normal to the disc plane, segmental bending moment, and segmental ROM were analyzed at each grid point. Analysis of MSU mechanics and ROM for the ProDisc-L and Simulated Implant cases revealed that the two conditions were not comparable. Transfer of tissue pretension from the implant to the Spine Robot on removal of the implant, and dynamic contact forces at the implant surfaces were the contributing factors to the differences observed. Simulated COR testing demonstrated that the posterior tissue response was sensitive to varying placements of the simulated implant. For both implant sizes, posterior positioning of the COR required distraction of the disc space. During flexion, posterior positioning resulted in significantly higher shear and axial forces as well as a trend for reduced ROM. ROM in flexion may have been influenced by different starting positions within the neutral zone due to disc space distraction. During extension, the posterior placement of the COR reduced loading and increased rotation suggesting better alignment with, or separation of the facet joints. This novel study was able to delineate significant differences in spinal tissue response to varying simulated sizes and placements of an ideal fixed COR TDR device. The results of this study suggested that with both implant sizes the posterior placement of the COR will tend to distract the disc space and provide significantly increased ROM in extension at the expense of increased loads on posterior ligaments in flexion

    Personalized Hip and Knee Joint Replacement

    Get PDF
    This open access book describes and illustrates the surgical techniques, implants, and technologies used for the purpose of personalized implantation of hip and knee components. This new and flourishing treatment philosophy offers important benefits over conventional systematic techniques, including component positioning appropriate to individual anatomy, improved surgical reproducibility and prosthetic performance, and a reduction in complications. The techniques described in the book aim to reproduce patients’ native anatomy and physiological joint laxity, thereby improving the prosthetic hip/knee kinematics and functional outcomes in the quest of the forgotten joint. They include kinematically aligned total knee/total hip arthroplasty, partial knee replacement, and hip resurfacing. The relevance of available and emerging technological tools for these personalized approaches is also explained, with coverage of, for example, robotics, computer-assisted surgery, and augmented reality. Contributions from surgeons who are considered world leaders in diverse fields of this novel surgical philosophy make this open access book will invaluable to a wide readership, from trainees at all levels to consultants practicing lower limb surger