155 research outputs found

    Methodological consensus on clinical proton MRS of the brain: Review and recommendations

    Get PDF
    © 2019 International Society for Magnetic Resonance in Medicine Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use

    Magnetic resonance spectroscopic imaging in gliomas: clinical diagnosis and radiotherapy planning

    Get PDF
    The reprogramming of cellular metabolism is a hallmark of cancer diagnosis and prognosis. Proton magnetic resonance spectroscopic imaging (MRSI) is a non-invasive diagnostic technique for investigating brain metabolism to establish cancer diagnosis and IDH gene mutation diagnosis as well as facilitate pre-operative planning and treatment response monitoring. By allowing tissue metabolism to be quantified, MRSI provides added value to conventional MRI. MRSI can generate metabolite maps from a single volume or multiple volume elements within the whole brain. Metabolites such as NAA, Cho and Cr, as well as their ratios Cho:NAA ratio and Cho:Cr ratio, have been used to provide tumor diagnosis and aid in radiation therapy planning as well as treatment assessment. In addition to these common metabolites, 2-hydroxygluterate (2HG) has also been quantified using MRSI following the recent discovery of IDH mutations in gliomas. This has opened up targeted drug development to inhibit the mutant IDH pathway. This review provides guidance on MRSI in brain gliomas, including its acquisition, analysis methods, and evolving clinical applications

    A review of machine learning applications for the proton MR spectroscopy workflow

    Get PDF
    This literature review presents a comprehensive overview of machine learning (ML) applications in proton MR spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state-of-the-art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the MR field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.</p

    Improving the Clinical Use of Magnetic Resonance Spectroscopy for the Analysis of Brain Tumours using Machine Learning and Novel Post-Processing Methods

    Get PDF
    Magnetic Resonance Spectroscopy (MRS) provides unique and clinically relevant information for the assessment of several diseases. However, using the currently available tools, MRS processing and analysis is time-consuming and requires profound expert knowledge. For these two reasons, MRS did not gain general acceptance as a mainstream diagnostic technique yet, and the currently available clinical tools have seen little progress during the past years. MRS provides localized chemical information non-invasively, making it a valuable technique for the assessment of various diseases and conditions, namely brain, prostate and breast cancer, and metabolic diseases affecting the brain. In brain cancer, MRS is normally used for: (1.) differentiation between tumors and non-cancerous lesions, (2.) tumor typing and grading, (3.) differentiation between tumor-progression and radiation necrosis, and (4.) identification of tumor infiltration. Despite the value of MRS for these tasks, susceptibility differences associated with tissue-bone and tissue-air interfaces, as well as with the presence of post-operative paramagnetic particles, affect the quality of brain MR spectra and consequently reduce their clinical value. Therefore, the proper quality management of MRS acquisition and processing is essential to achieve unambiguous and reproducible results. In this thesis, special emphasis was placed on this topic. This thesis addresses some of the major problems that limit the use of MRS in brain tumors and focuses on the use of machine learning for the automation of the MRS processing pipeline and for assisting the interpretation of MRS data. Three main topics were investigated: (1.) automatic quality control of MRS data, (2.) identification of spectroscopic patterns characteristic of different tissue-types in brain tumors, and (3.) development of a new approach for the detection of tumor-related changes in GBM using MRSI data. The first topic tackles the problem of MR spectra being frequently affected by signal artifacts that obscure their clinical information content. Manual identification of these artifacts is subjective and is only practically feasible for single-voxel acquisitions and in case the user has an extensive experience with MRS. Therefore, the automatic distinction between data of good or bad quality is an essential step for the automation of MRS processing and routine reporting. The second topic addresses the difficulties that arise while interpreting MRS results: the interpretation requires expert knowledge, which is not available at every site. Consequently, the development of methods that enable the easy comparison of new spectra with known spectroscopic patterns is of utmost importance for clinical applications of MRS. The third and last topic focuses on the use of MRSI information for the detection of tumor-related effects in the periphery of brain tumors. Several research groups have shown that MRSI information enables the detection of tumor infiltration in regions where structural MRI appears normal. However, many of the approaches described in the literature make use of only a very limited amount of the total information contained in each MR spectrum. Thus, a better way to exploit MRSI information should enable an improvement in the detection of tumor borders, and consequently improve the treatment of brain tumor patients. The development of the methods described was made possible by a novel software tool for the combined processing of MRS and MRI: SpectrIm. This tool, which is currently distributed as part of the jMRUI software suite (www.jmrui.eu), is ubiquitous to all of the different methods presented and was one of the main outputs of the doctoral work. Overall, this thesis presents different methods that, when combined, enable the full automation of MRS processing and assist the analysis of MRS data in brain tumors. By allowing clinical users to obtain more information from MRS with less effort, this thesis contributes to the transformation of MRS into an important clinical tool that may be available whenever its information is of relevance for patient management

    MP-PCA denoising for diffusion MRS data: promises and pitfalls

    Full text link
    Diffusion-weighted (DW) magnetic resonance spectroscopy (MRS) suffers from a lower signal to noise ratio (SNR) compared to conventional MRS owing to the addition of diffusion attenuation. This technique can therefore strongly benefit from noise reduction strategies. In the present work, the Marchenko-Pastur principal component analysis (MP-PCA) denoising is tested on Monte Carlo simulations and on in vivo DW-MRS data acquired at 9.4T in the rat brain. We provide a descriptive study of the effects observed following different MP-PCA denoising strategies (denoising the entire matrix versus using a sliding window), in terms of apparent SNR, rank selection, noise correlation within and across b-values and quantification of metabolite concentrations and fitted diffusion coefficients. MP-PCA denoising yielded an increased apparent SNR, a more accurate B0 drift correction between shots, and similar estimates of metabolite concentrations and diffusivities compared to the raw data. No spectral residuals on individual shots were observed but correlations in the noise level across shells were introduced, an effect which was mitigated using a sliding window, but which should be carefully considered.Comment: Cristina Cudalbu and Ileana O. Jelescu have contributed equally to this manuscrip

    MP-PCA denoising for diffusion MRS data: promises and pitfalls.

    Get PDF
    Diffusion-weighted (DW) magnetic resonance spectroscopy (MRS) suffers from a lower signal to noise ratio (SNR) compared to conventional MRS owing to the addition of diffusion attenuation. This technique can therefore strongly benefit from noise reduction strategies. In the present work, Marchenko-Pastur principal component analysis (MP-PCA) denoising is tested on Monte Carlo simulations and on in vivo DW-MRS data acquired at 9.4T in rat brain and at 3T in human brain. We provide a descriptive study of the effects observed following different MP-PCA denoising strategies (denoising the entire matrix versus using a sliding window), in terms of apparent SNR, rank selection, noise correlation within and across b-values and quantification of metabolite concentrations and fitted diffusion coefficients. MP-PCA denoising yielded an increased apparent SNR, a more accurate B0 drift correction between shots, and similar estimates of metabolite concentrations and diffusivities compared to the raw data. No spectral residuals on individual shots were observed but correlations in the noise level across shells were introduced, an effect which was mitigated using a sliding window, but which should be carefully considered

    Detection of brain metabolites in magnetic resonance spectroscopy

    Get PDF
    Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.Includes bibliographical references (p. 59-61).While magnetic resonance imaging (MRI) derives its signal from protons in water, additional and potentially important biochemical compounds are detectable in vivo within the proton spectrum. The detection and mapping of these much weaker signals is known as magnetic resonance spectroscopy or spectroscopic imaging. Among the complicating factors for this modality applied for human clinical imaging are limited chemical-shift dispersion and J-coupling that cause spectral overlap and complicated spectral shapes that limit detection and separation of several brain metabolites using MR spectroscopic imaging. Existing techniques for improved detection include so-called 2D spectroscopy, where additional encoding steps aid in the separation of compounds with overlapping chemical shift. This is achieved by collecting spectral data over a range of timing parameters and introducing an additional frequency axis, fl. Spectral editing techniques attempt to enhance metabolite signal detection along fl in order to resolve specific metabolite signals. While these techniques have been shown to improve signal separation, they carry a penalty in scan time and more complicated reconstruction compared to conventional spectroscopy, and are often prohibitive when combined with spectroscopic imaging. The task of this thesis is to characterize and optimize existing 2D spectroscopy techniques for improved metabolite resolution with reduced number of timing steps through numerical simulation and experimental validation in phantoms.Trina Kok.S.M
    corecore