79 research outputs found
Wide field epiretinal micro-electrode-design and feature test
This study was aimed to design and fabricate a wide field implantable epi-retinal microelectrode array for the purpose of retinal repair, and to perform electrochemical test on the array. With parylene as flexible substrate material and Pt as electrode and route material, microelectrode array prototypes was designed and fabricated, and electric characteristics of the array was tested with the three-electrode test system. The feature analysis showed that morphological and electrical properties of the array well met the requirements of implantation and electrical stimulation of retina. The microelectrode array can be put in the in vivo electrophysiological experiments on animal and can perform reliably. © 2013 IEEE.published_or_final_versio
Active C4 electrodes for local field potential recording applications
Extracellular neural recording, with multi-electrode arrays (MEAs), is a powerful method used to study neural function at the network level. However, in a high density array, it can be costly and time consuming to integrate the active circuit with the expensive electrodes. In this paper, we present a 4 mm × 4 mm neural recording integrated circuit (IC) chip, utilizing IBM C4 bumps as recording electrodes, which enable a seamless active chip and electrode integration. The IC chip was designed and fabricated in a 0.13 μm BiCMOS process for both in vitro and in vivo applications. It has an input-referred noise of 4.6 μV rms for the bandwidth of 10 Hz to 10 kHz and a power dissipation of 11.25 mW at 2.5 V, or 43.9 μW per input channel. This prototype is scalable for implementing larger number and higher density electrode arrays. To validate the functionality of the chip, electrical testing results and acute in vivo recordings from a rat barrel cortex are presented.R01 NS072385 - NINDS NIH HHS; 1R01 NS072385 - NINDS NIH HH
A 16 x 16 CMOS amperometric microelectrode array for simultaneous electrochemical measurements
There is a requirement for an electrochemical sensor technology capable of making multivariate measurements in environmental, healthcare, and manufacturing applications. Here, we present a new device that is highly parallelized with an excellent bandwidth. For the first time, electrochemical cross-talk for a chip-based sensor is defined and characterized. The new CMOS electrochemical sensor chip is capable of simultaneously taking multiple, independent electroanalytical measurements. The chip is structured as an electrochemical cell microarray, comprised of a microelectrode array connected to embedded self-contained potentiostats. Speed and sensitivity are essential in dynamic variable electrochemical systems. Owing to the parallel function of the system, rapid data collection is possible while maintaining an appropriately low-scan rate. By performing multiple, simultaneous cyclic voltammetry scans in each of the electrochemical cells on the chip surface, we are able to show (with a cell-to-cell pitch of 456 μm) that the signal cross-talk is only 12% between nearest neighbors in a ferrocene rich solution. The system opens up the possibility to use multiple independently controlled electrochemical sensors on a single chip for applications in DNA sensing, medical diagnostics, environmental sensing, the food industry, neuronal sensing, and drug discovery
Recommended from our members
Methodology for rapid assessment of blood lithium levels in ultramicro volumes of blood plasma for applications in personal monitoring of patients with bipolar mood disorder
Bipolar disorder (BD) is a common mental health condition, characterized by extreme changes in mood, energy, and behavior. BD is often managed through mood-stabilizing medications, of which lithium formulations remain the most reliable and effective at reducing the risk of suicide. To achieve adequate and consistent efficacy, lithium concentrations need to be maintained within a narrow therapeutic range (0.4 to 1.2  mmol  /  L). Because of its narrow therapeutic index, long-term lithium therapy is associated with serious side effects and risks of toxicity. It is believed that the availability of a personal blood lithium analyzer would benefit patients who are on lithium treatment. We detail the results of a spectrophotometric method performed on ultramicro volumes to determine blood plasma lithium concentrations as compared with reference measurements of flame photometry, and validated in samples of unknown lithium content. Applying multiple linear regression, lithium concentrations could be determined in a rapid manner using full-range spectra or triwavelength data. Both techniques highly correlated with reference standards and could predict lithium levels accurately (R2  =  0.794214 and RMSEP  =  0.209584, and R2  =  0.863921 and RMSEP  =  0.167524, respectively). Therefore, this method can be a useful for rapid assessment of blood lithium in nonlaboratory settings i.e., general practices, hospital clinics, and community health centers by healthcare professionals and/or by patients. Future work will now focus on completion of a miniaturized and integrated system that will deliver a portable and personal lithium-monitoring device
Development of a Three Dimensional Neural Sensing Device by a Stacking Method
This study reports a new stacking method for assembling a 3-D microprobe array. To date, 3-D array structures have usually been assembled with vertical spacers, snap fasteners and a supporting platform. Such methods have achieved 3-D structures but suffer from complex assembly steps, vertical interconnection for 3-D signal transmission, low structure strength and large implantable opening. By applying the proposed stacking method, the previous techniques could be replaced by 2-D wire bonding. In this way, supporting platforms with slots and vertical spacers were no longer needed. Furthermore, ASIC chips can be substituted for the spacers in the stacked arrays to achieve system integration, design flexibility and volume usage efficiency. To avoid overflow of the adhesive fluid during assembly, an anti-overflow design which made use of capillary action force was applied in the stacking method as well. Moreover, presented stacking procedure consumes only 35 minutes in average for a 4 × 4 3-D microprobe array without requiring other specially made assembly tools. To summarize, the advantages of the proposed stacking method for 3-D array assembly include simplified assembly process, high structure strength, smaller opening area and integration ability with active circuits. This stacking assembly technique allows an alternative method to create 3-D structures from planar components
Recommended from our members
A Method for Rapid, Reliable, and Low-Volume Measurement of Lithium in Blood for Use in Bipolar Disorder Treatment Management
GOAL: Lithium preparations are considered the most reliable mood stabilizers for patients with Bipolar Disorder (BD), and are the most effective at reducing the risk of suicide. However, maintaining blood lithium concentration within the narrow therapeutic range of 0.4-1.2 mEq is crucial but extremely difficult. The aim of this work is to develop a personal lithium blood level analyzer using a novel method of combined optical and electrical impedance spectroscopy to test micro volumes of spiked samples of human blood. RESULTS: Impedance measurements alone showed a limit of detection of less than 0.1 mEq within the therapeutic range, whereas optical measurements could verify the presence of lithium and provide a degree of lithium content. Optical specificity to lithium was further verified in qualitative assessment of lithium spiked blood samples with varying concentrations of sodium. Moreover, analysis of multiple linear regression yielded a prediction model of R2 = 0.322716 and RMSEP =0.223602 for optical measurements only using feature wavelengths, which were found to appear at minima 560 and 605 nm. Combined with impedance measurements, prediction of lithium concentration in samples with unknown lithium content was significantly increased to R2 = 0.876438, and RMSEP = 0.513554. CONCLUSION: The combination of optical and impedance modalities for determinations of blood lithium resulted in significant improvement to the sensitivity and accuracy of measurement. SIGNIFICANCE: Results are complementary of the proposed opto-impedance method, and future work will now focus on the technical development of an integrated and miniaturized system for measurement of lithium levels in blood with a high level of accuracy and sensitivity
On-line monitoring of the crystallization process: relationship between crystal size and electrical impedance spectra
On-line monitoring of crystal size in the crystallization process is crucial to many pharmaceutical and fine-chemical industrial applications. In this paper, a novel method is proposed for the on-line monitoring of the cooling crystallization process of L-glutamic acid (LGA) using electrical impedance spectroscopy (EIS). The EIS method can be used to monitor the growth of crystal particles relying on the presence of an electrical double layer on the charged particle surface and the polarization of double layer under the excitation of alternating electrical field. The electrical impedance spectra and crystal size were measured on-line simultaneously by an impedance analyzer and focused beam reflectance measurement (FBRM), respectively. The impedance spectra were analyzed using the equivalent circuit model and the equivalent circuit elements in the model can be obtained by fitting the experimental data. Two equivalent circuit elements, including capacitance (C 2) and resistance (R 2) from the dielectric polarization of the LGA solution and crystal particle/solution interface, are in relation with the crystal size. The mathematical relationship between the crystal size and the equivalent circuit elements can be obtained by a non-linear fitting method. The function can be used to predict the change of crystal size during the crystallization process
- …