10 research outputs found

    Proposal and multicentric validation of a laparoscopic Roux-en-Y gastric bypass surgery ontology.

    Get PDF
    BACKGROUND Phase and step annotation in surgical videos is a prerequisite for surgical scene understanding and for downstream tasks like intraoperative feedback or assistance. However, most ontologies are applied on small monocentric datasets and lack external validation. To overcome these limitations an ontology for phases and steps of laparoscopic Roux-en-Y gastric bypass (LRYGB) is proposed and validated on a multicentric dataset in terms of inter- and intra-rater reliability (inter-/intra-RR). METHODS The proposed LRYGB ontology consists of 12 phase and 46 step definitions that are hierarchically structured. Two board certified surgeons (raters) with > 10 years of clinical experience applied the proposed ontology on two datasets: (1) StraBypass40 consists of 40 LRYGB videos from Nouvel Hôpital Civil, Strasbourg, France and (2) BernBypass70 consists of 70 LRYGB videos from Inselspital, Bern University Hospital, Bern, Switzerland. To assess inter-RR the two raters' annotations of ten randomly chosen videos from StraBypass40 and BernBypass70 each, were compared. To assess intra-RR ten randomly chosen videos were annotated twice by the same rater and annotations were compared. Inter-RR was calculated using Cohen's kappa. Additionally, for inter- and intra-RR accuracy, precision, recall, F1-score, and application dependent metrics were applied. RESULTS The mean ± SD video duration was 108 ± 33 min and 75 ± 21 min in StraBypass40 and BernBypass70, respectively. The proposed ontology shows an inter-RR of 96.8 ± 2.7% for phases and 85.4 ± 6.0% for steps on StraBypass40 and 94.9 ± 5.8% for phases and 76.1 ± 13.9% for steps on BernBypass70. The overall Cohen's kappa of inter-RR was 95.9 ± 4.3% for phases and 80.8 ± 10.0% for steps. Intra-RR showed an accuracy of 98.4 ± 1.1% for phases and 88.1 ± 8.1% for steps. CONCLUSION The proposed ontology shows an excellent inter- and intra-RR and should therefore be implemented routinely in phase and step annotation of LRYGB

    EXACT: a collaboration toolset for algorithm-aided annotation of images with annotation version control

    Get PDF
    In many research areas, scientific progress is accelerated by multidisciplinary access to image data and their interdisciplinary annotation. However, keeping track of these annotations to ensure a high-quality multi-purpose data set is a challenging and labour intensive task. We developed the open-source online platform EXACT (EXpert Algorithm Collaboration Tool) that enables the collaborative interdisciplinary analysis of images from different domains online and offline. EXACT supports multi-gigapixel medical whole slide images as well as image series with thousands of images. The software utilises a flexible plugin system that can be adapted to diverse applications such as counting mitotic figures with a screening mode, finding false annotations on a novel validation view, or using the latest deep learning image analysis technologies. This is combined with a version control system which makes it possible to keep track of changes in the data sets and, for example, to link the results of deep learning experiments to specific data set versions. EXACT is freely available and has already been successfully applied to a broad range of annotation tasks, including highly diverse applications like deep learning supported cytology scoring, interdisciplinary multi-centre whole slide image tumour annotation, and highly specialised whale sound spectroscopy clustering

    Supporting laparoscopic general surgery training with digital technology: The United Kingdom and Ireland paradigm

    Get PDF
    Surgical training in the UK and Ireland has faced challenges following the implementation of the European Working Time Directive and postgraduate training reform. The health services are undergoing a digital transformation; digital technology is remodelling the delivery of surgical care and surgical training. This review aims to critically evaluate key issues in laparoscopic general surgical training and the digital technology such as virtual and augmented reality, telementoring and automated workflow analysis and surgical skills assessment. We include pre-clinical, proof of concept research and commercial systems that are being developed to provide solutions. Digital surgical technology is evolving through interdisciplinary collaboration to provide widespread access to high-quality laparoscopic general surgery training and assessment. In the future this could lead to integrated, context-aware systems that support surgical teams in providing safer surgical care

    SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction

    Get PDF
    In computer vision, reference datasets from simulation and real outdoor scenes have been highly successful in promoting algorithmic development in stereo reconstruction. Endoscopic stereo reconstruction for surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surface properties and the presence of blood and smoke. These issues present difficulties for both stereo reconstruction itself and also for standardised dataset production. Previous datasets have been produced using computed tomography (CT) or structured light reconstruction on phantom or ex vivo models. We present a stereo-endoscopic reconstruction validation dataset based on cone-beam CT (SERV-CT). Two ex vivo small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Subsequent orientation of the endoscope was manually aligned to match the stereoscopic view and benchmark disparities, depths and occlusions are calculated. The requirement of a CT scan limited the number of stereo pairs to 8 from each ex vivo sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of around 2 pixels and a depth accuracy of about 2 mm. A simplified reference dataset is provided consisting of endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types, including smooth specular surfaces, as well as significant variation of depth. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths covering the majority of the endoscopic image. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms

    Comparative validation of machine learning algorithms for surgical workflow and skill analysis with the HeiChole benchmark

    Get PDF
    Purpose: Surgical workflow and skill analysis are key technologies for the next generation of cognitive surgical assistance systems. These systems could increase the safety of the operation through context-sensitive warnings and semi-autonomous robotic assistance or improve training of surgeons via data-driven feedback. In surgical workflow analysis up to 91% average precision has been reported for phase recognition on an open data single-center video dataset. In this work we investigated the generalizability of phase recognition algorithms in a multicenter setting including more difficult recognition tasks such as surgical action and surgical skill. Methods: To achieve this goal, a dataset with 33 laparoscopic cholecystectomy videos from three surgical centers with a total operation time of 22 h was created. Labels included framewise annotation of seven surgical phases with 250 phase transitions, 5514 occurences of four surgical actions, 6980 occurences of 21 surgical instruments from seven instrument categories and 495 skill classifications in five skill dimensions. The dataset was used in the 2019 international Endoscopic Vision challenge, sub-challenge for surgical workflow and skill analysis. Here, 12 research teams trained and submitted their machine learning algorithms for recognition of phase, action, instrument and/or skill assessment. Results: F1-scores were achieved for phase recognition between 23.9% and 67.7% (n = 9 teams), for instrument presence detection between 38.5% and 63.8% (n = 8 teams), but for action recognition only between 21.8% and 23.3% (n = 5 teams). The average absolute error for skill assessment was 0.78 (n = 1 team). Conclusion: Surgical workflow and skill analysis are promising technologies to support the surgical team, but there is still room for improvement, as shown by our comparison of machine learning algorithms. This novel HeiChole benchmark can be used for comparable evaluation and validation of future work. In future studies, it is of utmost importance to create more open, high-quality datasets in order to allow the development of artificial intelligence and cognitive robotics in surgery
    corecore