86 research outputs found

    High-performance motor drives

    Get PDF
    This article reviews the present state and trends in the development of key parts of controlled induction motor drive systems: converter topologies, modulation methods, as well as control and estimation techniques. Two- and multilevel voltage-source converters, current-source converters, and direct converters are described. The main part of all the produced electric energy is used to feed electric motors, and the conversion of electrical power into mechanical power involves motors ranges from less than 1 W up to several dozen megawatts

    THD Analysis of a Seven, Nine, and Eleven Level Cascaded H-Bridge Multilevel Inverter for Different Loads

    Get PDF
    A multilevel inverter is implemented for generating the required staircase AC voltage of output from various steps of voltages of DC sources. The multilevel inverter gives a better harmonic spectrum and a compatible quality of output. This article delves into an analytical analysis of the total harmonic distortion (THD) of different multilevel inverters which employ a multicarrier PWM technique. This technique is implemented for operating the switches at their respective angle of conduction. This paper deals with various cascaded H-Bridge multilevel inverters (CMI) with various loads that are modelled by implementing the MATLAB/Simulink platform. The output gives a better result of the proposed model in terms that it is helpful towards reducing the THD and the losses of switching

    The Age of Multilevel Converters Arrives

    Get PDF
    This work is devoted to review and analyze the most relevant characteristics of multilevel converters, to motivate possible solutions, and to show that we are in a decisive instant in which energy companies have to bet on these converters as a good solution compared with classic two-level converters. This article presents a brief overview of the actual applications of multilevel converters and provides an introduction of the modeling techniques and the most common modulation strategies. It also addresses the operational and technological issues

    Study and evaluation of distributed power electronic converters in photovoltaic generation applications

    Get PDF
    This research project has proposed a new modulation technique called “Local Carrier Pulse Width Modulation” (LC-PWM) for MMCs with different cell voltages, taking into account the measured cell voltages to generate switching sequences with more accurate timing. It also adapts the modulator sampling period to improve the transitions from level to level, an important issue to reduce noise at the internal circulating currents. As a result, the new modulation LC-PWM technique reduces the output distortion in a wider range of voltage situations. Furthermore, it effectively eliminates unnecessary AC components of circulating currents, resulting in lower power losses and higher MMC efficiency.Departamento de Tecnología ElectrónicaDoctorado en Ingeniería Industria

    Enhanced decoupling current scheme with selective harmonic elimination pulse width modulation for cascaded multilevel inverter based static synchronous compensator

    Get PDF
    This dissertation is dedicated to a comprehensive study and performance analysis of the transformer-less Multilevel Cascaded H-bridge Inverter (MCHI) based STATic synchronous COMpensator (STATCOM). Among the shunt-connected Flexible AC Transmission System (FACTS) controllers, STATCOM has shown extensive feasibility and effectiveness in solving a wide range of power quality problems. By referring to the literature reviews, MCHI with separated DC capacitors is certainly the most versatile power inverter topology for STATCOM applications. However, due to the ill-defined transfer functions, complex control schemes and formulations were emerged to achieve a low-switching frequency high-bandwidth power control. As a result, adequate controller parameters were generally obtained by using trial and error method, which were practically ineffective and time-consuming. In this dissertation, the STATCOM is controlled to provide reactive power (VAR) compensation at the Point of Common Coupling (PCC) under different loading conditions. The goal of this work is to enhance the performance of the STATCOM with the associated proposed control scheme in achieving high dynamic response, improving transient performance, and producing high-quality output voltage waveform. To evaluate the superiority of the proposed control scheme, intensive simulation studies and numerous experiments are conducted accordingly, where a very good match between the simulation results and the experimental results is achieved in all cases and documented in this dissertation

    Comparative Analysis of Multilevel Converters for Medium-Voltage Applications

    Get PDF
    The electric energy demand has been steadily growing during the last century, and all forecasts indicate that it will keep growing in the following years. Within this frame, and due to all the problems that this demand increase generate in the environment, it is necessary improving the current techniques of electric energy conversion and transmission in order to increase the whole system efficiency. On the other hand, it is also necessary increasing the renewable energy resources exploitation through more efficient generation systems. According to these lines, the power electronics systems that have been installed in the last decades allowed to obtain better efficiency from the renewable natural resources like the wind or the solar power. These systems have also notably improved the quality of the power supplied, reducing the losses through what are known as power quality applications. Power converters are currently essential in any power electronics system. Within them, the multilevel converters specially suppose a breakthrough compared with the classical two level converters, as they allow obtaining voltage and current signals with lower harmonic content, what means fewer losses in high power medium voltage applications. In this Thesis a comparative study of some multilevel converter topologies normally used in high power medium voltage applications is done. The objective is analyzing in detail each topology and comparing it with the rest following different criteria, with the aim to know the advantages and drawbacks of each one and to realize which one is more suitable for each application

    Applications of Power Electronics:Volume 1

    Get PDF

    Mitigation of power quality issues due to high penetration of renewable energy sources in electric grid systems using three-phase APF/STATCOM technologies: a review.

    Get PDF
    This study summarizes an analytical review on the comparison of three-phase static compensator (STATCOM) and active power filter (APF) inverter topologies and their control schemes using industrial standards and advanced high-power configurations. Transformerless and reduced switch count topologies are the leading technologies in power electronics that aim to reduce system cost and offer the additional benefits of small volumetric size, lightweight and compact structure, and high reliability. A detailed comparison of the topologies, control strategies and implementation structures of grid-connected high-power converters is presented. However, reducing the number of power semiconductor devices, sensors, and control circuits requires complex control strategies. This study focuses on different topological devices, namely, passive filters, shunt and hybrid filters, and STATCOMs, which are typically used for power quality improvement. Additionally, appropriate control schemes, such as sinusoidal pulse width modulation (SPWM) and space vector PWM techniques, are selected. According to recent developments in shunt APF/STATCOM inverters, simulation and experimental results prove the effectiveness of APF/STATCOM systems for harmonic mitigation based on the defined limit in IEEE-519

    Online Control of Modular Active Power Line Conditioner to Improve Performance of Smart Grid

    Get PDF
    This thesis is explored the detrimental effects of nonlinear loads in distribution systems and investigated the performances of shunt FACTS devices to overcome these problems with the following main contribution: APLC is an advanced shunt active filter which can mitigate the fundamental voltage harmonic of entire network and limit the THDv and individual harmonic distortion of the entire network below 5% and 3%, respectively, as recommended by most standards such as the IEEE-519

    Performance Enhancement of Shunt APFs Using Various Topologies, Control Schemes and Optimization Techniques

    Get PDF
    Following the advent of solid-state power electronics technology, extensive usage of nonlinear loads has lead to severe disturbances like harmonics, unbalanced currents, excessive neutral current and reactive power burden in three-phase power systems. Harmonics lower down the efficiency and power factor, increase losses, and result in electromagnetic interference with neighbouring communication lines and other harmful consequences. Over the years, active power filter (APF) has been proven to be a brilliant solution among researchers and application engineers dealing with power quality issues. Selection of proper reference compensation current extraction scheme plays the most crucial role in APF performance. This thesis describes three time-domain schemes viz. Instantaneous active and reactive power (p-q), modified p-q, and Instantaneous active and reactive current component (i_d-i_q) schemes. The objective is to bring down the source current THD below 5%, to satisfy the IEEE-519 Standard recommendations on harmonic limits. Comparative evaluation shows that, i_d-i_q is the best APF control scheme irrespective of supply and load conditions. Results are validated with simulations, followed by real-time analysis in RT-Lab.In view of the fact that APFs are generally comprised of voltage source inverter (VSI) based on PWM, undesirable power loss takes place inside it due to the inductors and switching devices. This is effectively minimized with inverter DC-link voltage regulation using PI controller. The controller gains are determined using optimization technique, as the conventional linearized tuning of PI controller yield inadequate results for a range of operating conditions due to the complex, nonlinear and time-varying nature of power system networks. Developed by hybridization of Particle swarm optimization (PSO) and Bacterial foraging optimization (BFO), an Enhanced BFO technique is proposed here so as to overcome the drawbacks of both PSO and BFO, and accelerate the convergence of optimization problem. Extensive simulation studies and RT-Lab real-time investigations are performed for comparative assessment of proposed implementation of PSO, BFO and Enhanced BFO on APF. This validates that, the APF employing Enhanced BFO offers superior harmonic compensation compared to other alternatives, by lowering down the source current THD to drastically small values.Another indispensable aspect of APF is its topology, which plays an essential role in meeting harmonic current requirement of nonlinear loads. APFs are generally developed with current-source or voltage-source inverters. The latter is more convenient as it is lighter, cheaper, and expandable to multilevel and multistep versions for improved performance at high power ratings with lower switching frequencies. There can be different topologies of VSI depending on the type of supply system. With each topology, constraints related to DC-link voltage regulation change. For effective compensation, irrespective of the number and rating of DC-link capacitors used in any particular topology, voltages across them must be maintained constant with optimal regulation of DC-link voltage. Various topologies for three-phase three-wire systems (conventional two-level and multilevel VSIs) and four-wire systems (split-capacitor (2C), four-leg (4L), three H-bridges (3HB) and three-level H-bridge (3L-HB) VSIs) are analyzed and compared based on component requirements, effectiveness in harmonic compensation, cost and area of application
    corecore