    Toward a priori noise characterization for real-time edge-aware denoising in fluoroscopic devices

    Get PDF
    Background: Low-dose X-ray images have become increasingly popular in the last decades, due to the need to guarantee the lowest reasonable patient’s exposure. Dose reduction causes a substantial increase of quantum noise, which needs to be suitably suppressed. In particular, real-time denoising is required to support common interventional fluoroscopy procedures. The knowledge of noise statistics provides precious information that helps to improve denoising performances, thus making noise estimation a crucial task for effective denoising strategies. Noise statistics depend on different factors, but are mainly influenced by the X-ray tube settings, which may vary even within the same procedure. This complicates real-time denoising, because noise estimation should be repeated after any changes in tube settings, which would be hardly feasible in practice. This work investigates the feasibility of an a priori characterization of noise for a single fluoroscopic device, which would obviate the need for inferring noise statics prior to each new images acquisition. The noise estimation algorithm used in this study was tested in silico to assess its accuracy and reliability. Then, real sequences were acquired by imaging two different X-ray phantoms via a commercial fluoroscopic device at various X-ray tube settings. Finally, noise estimation was performed to assess the matching of noise statistics inferred from two different sequences, acquired independently in the same operating conditions. Results: The noise estimation algorithm proved capable of retrieving noise statistics, regardless of the particular imaged scene, also achieving good results even by using only 10 frames (mean percentage error lower than 2%). The tests performed on the real fluoroscopic sequences confirmed that the estimated noise statistics are independent of the particular informational content of the scene from which they have been inferred, as they turned out to be consistent in sequences of the two different phantoms acquired independently with the same X-ray tube settings. Conclusions: The encouraging results suggest that an a priori characterization of noise for a single fluoroscopic device is feasible and could improve the actual implementation of real-time denoising strategies that take advantage of noise statistics to improve the trade-off between noise reduction and details preservation

    Hardware implementation of a spatio-temporal average filter for real-time denoising of fluoroscopic images

    No full text
    An electronic system for the real-time denoising of fluoroscopic images is proposed in this paper. Fluoroscopic devices use X-rays to obtain real-time moving images of patients and support many surgical interventions and a variety of diagnostic procedures. In order to avoid risks for the patient, X-ray intensity has to be kept acceptably low during the clinical applications. This implies that fluoroscopic images are corrupted by large quantum noise (Poisson-distributed). Real-time noise reduction can offer a better visual perception to doctors and possible further reductions of the dose. The proposed circuit implements a spatio-temporal filter optimized for the removal of the quantum noise while preserving video edges and the prompt response of the image to the introduction of new features in the field. The filter incorporates information on the dependence of the standard deviation of the noise on the local brightness of the image and performs a conditioned average operation. The proposed circuit is implemented on FPGA (Field Programmable Gate Array) device allowing the real time elaboration of video streams composed by frames with 1024×1024 pixel and uses an external DDR2 (Double Data Rate 2) memory for the storage and the reuse of the fluoroscopic frames needed by the filter. When implemented on StratixIV-GX70 FPGA the circuit is able to process up to 49 fps (frames per second) while using 80% of the logic resources of the FPGA

    Real-Time Quantum Noise Suppression In Very Low-Dose Fluoroscopy

    Get PDF
    Fluoroscopy provides real-time X-ray screening of patient's organs and of various radiopaque objects, which make it an invaluable tool for many interventional procedures. For this reason, the number of fluoroscopy screenings has experienced a consistent growth in the last decades. However, this trend has raised many concerns about the increase in X-ray exposure, as even low-dose procedures turned out to be not as safe as they were considered, thus demanding a rigorous monitoring of the X-ray dose delivered to the patients and to the exposed medical staff. In this context, the use of very low-dose protocols would be extremely beneficial. Nonetheless, this would result in very noisy images, which need to be suitably denoised in real-time to support interventional procedures. Simple smoothing filters tend to produce blurring effects that undermines the visibility of object boundaries, which is essential for the human eye to understand the imaged scene. Therefore, some denoising strategies embed noise statistics-based criteria to improve their denoising performances. This dissertation focuses on the Noise Variance Conditioned Average (NVCA) algorithm, which takes advantage of the a priori knowledge of quantum noise statistics to perform noise reduction while preserving the edges and has already outperformed many state-of-the-art methods in the denoising of images corrupted by quantum noise, while also being suitable for real-time hardware implementation. Different issues are addressed that currently limit the actual use of very low-dose protocols in clinical practice, e.g. the evaluation of actual performances of denoising algorithms in very low-dose conditions, the optimization of tuning parameters to obtain the best denoising performances, the design of an index to properly measure the quality of X-ray images, and the assessment of an a priori noise characterization approach to account for time-varying noise statistics due to changes of X-ray tube settings. An improved NVCA algorithm is also presented, along with its real-time hardware implementation on a Field Programmable Gate Array (FPGA). The novel algorithm provides more efficient noise reduction performances also for low-contrast moving objects, thus relaxing the trade-off between noise reduction and edge preservation, while providing a further reduction of hardware complexity, which allows for low usage of logic resources also on small FPGA platforms. The results presented in this dissertation provide the means for future studies aimed at embedding the NVCA algorithm in commercial fluoroscopic devices to accomplish real-time denoising of very low-dose X-ray images, which would foster their actual use in clinical practice
    corecore