    OPTICAL GEOMETRY CALIBRATION METHOD FOR COMPUTED TOMOGRAPHY AND APPLICATIONS OF COMPACT MICROBEAM RADIATION THERAPY

    Get PDF
    Digital tomosynthesis is a type of limited angle tomography that allows for 3D information reconstructed from a set of X-ray projection images taken at various angles using an X-ray tube, a mechanical arm to rotate the tube, and a digital detector. Tomosynthesis reconstruction requires the knowledge of the precise location of the detector with respect to each X-ray source. Current clinical tomosynthesis methods use a physically coupled source and detector so the geometry is always known and is always the same. This makes it impractical for mobile or field operations. We demonstrated a free form tomosynthesis and free form computed tomography (CT) with a decoupled source and detector setup that uses a novel optical method for accurate and real-time geometry calibration. We accomplish this by using a camera to track the motion of the source relative to the detector. A checkerboard pattern is positioned on or next to the detector using an extension arm in such a way that the pattern will not move relative to the detector. A camera is mounted on the source in a way that the pattern is visible during imaging and will not move relative to the source. The image of the pattern captured by the camera is then used to determine the relative camera/pattern position and orientation by analyzing the pattern distortion. This allows for accurate, real time geometry calibration of the X-ray source relative to the detector. This method opens the doors for inexpensive upgrades to existing 2D imaging systems and an even more exciting application of a mobile, hand-held CT imaging system.Doctor of Philosoph

    The Design of X-Ray Film Reader with Film Presence Detector

    Get PDF
    X-Ray viewer is a tool for observing the results of X-Ray films using ray lighting. It aims to get clearer readings of X-Ray films by radiographers and doctors. X-Ray viewers in hospitals generally cannot be carried anywhere because they use fluorescent lamps as a source of radiation and use 220 Volt AC voltage directly. So that its use is less effective and efficient because it must be connected directly to a 220 Volt AC power source and requires large power. In this regard the author wants to design an X-Ray viewer tool that can be used to read the results of X-Ray films clearly and is portable so that the device can be used anywhere because it uses a battery as a voltage source and is equipped with a presence detection sensor film in order to save energy so that the use of tools is more effective and efficient

    Development and Evaluation of a Stationary Head Computed Tomography Scanner

    Get PDF
    X-Ray Computed Tomography (CT) is a widely used 3D imaging technique, proving indispensable in the diagnosis of medical conditions and pathologies. However, virtually all of today’s state-of-the-art CT systems rely on a rotating gantry to acquire projections spanning up to 360 degrees around the head and/or body. By replacing the rotating source and detector with a stationary array of x-ray sources and line detectors, a CT scanner could be potentially constructed with a smaller footprint and faster scanning speed. The subject of this dissertation is the design, construction, and evaluation of a stationary head CT (s-HCT) scanner capable of diagnosis of stroke and head trauma patients in limited resource areas such as forward operating bases. By bringing the diagnostic CT scanning capability to the patient, survival rates could potentially be greatly improved through quicker delivery of appropriate treatments. The scanner is made possible by recent advances in technologies related to CT, including x-ray sensor technology, iterative reconstruction methods, and distributed x-ray sources. Recently, carbon nanotube (CNT) x-ray source arrays have been utilized in a number of medical and security applications. The unique electronic scanning ability afforded by these systems can removes the need for a rotating gantry, producing a stationary system which potentially is more mechanically robust and could provide diagnostic CT images in a smaller footprint, with little to no loss in image quality.The use of 3 linear x-ray source arrays naturally results in a triangular shape, representing a radical departure from a traditional (circular) source ring. The final construction of the prototype proves that circular objects can still be reconstructed accurately even though the geometry of the system is triangular. Furthermore, the prototype has been able to acquire all of the projection data in scan times comparable to those of commercial scanners (< 1min), indicating the CNT x-ray and s-HCT technologies are developed enough for clinical trials. As part of an initial evaluation, several objects are imaged in a phantom imaging study, with results demonstrating the temporal and spatial resolution, as well as the accuracy and noise associated with the 3D reconstruction output.Doctor of Philosoph

    Virtual clinical trials in medical imaging: a review

    Get PDF
    The accelerating complexity and variety of medical imaging devices and methods have outpaced the ability to evaluate and optimize their design and clinical use. This is a significant and increasing challenge for both scientific investigations and clinical applications. Evaluations would ideally be done using clinical imaging trials. These experiments, however, are often not practical due to ethical limitations, expense, time requirements, or lack of ground truth. Virtual clinical trials (VCTs) (also known as in silico imaging trials or virtual imaging trials) offer an alternative means to efficiently evaluate medical imaging technologies virtually. They do so by simulating the patients, imaging systems, and interpreters. The field of VCTs has been constantly advanced over the past decades in multiple areas. We summarize the major developments and current status of the field of VCTs in medical imaging. We review the core components of a VCT: computational phantoms, simulators of different imaging modalities, and interpretation models. We also highlight some of the applications of VCTs across various imaging modalities

    Carbon Nanotube Based Stationary X-ray Tomosynthesis Scanner for Detection of Breast Cancer

    Get PDF
    In this dissertation, my Ph.D. research during the past six years will be presented. My research mainly focused on design, fabrication and characterization of devices based on carbon nanotubes (CNT). Since the discovery of CNT in 1991, the research focus has gradually shifted from material synthesis and characterization to devices and applications. During early stages of my Ph.D. study, I worked on synthesizing CNT using laser ablation method, and fabricating CNT-AFM tips and magnetic wire MFM tips. During the second half of my Ph.D. study, my research focused more on design, fabrication, and testing the xray sources and imaging systems based on CNT, including both single-beam system (microCT) and multi-beam system (tomosysthesis). During the last two years, I worked on the project to develop a novel imaging system (Argus) using CNT x-ray source array for breast cancer detection. This is the first stationary digital breast tomosynthesis (DBT) imaging system in the world. My research result has shown great clinical potentials of these imaging systems using x-ray source based on CNTs. This dissertation is composed by five chapters. In chapter one, the physics behind xray and field emission theory will be reviewed. Chapter two covers discovery, property and synthesis of CNT. Methods to fabricate CNT emitters and their emission property will also be introduced there. Single and multi beam x-ray sources and applications will be discussed in chapter three. The design and characteristic test results are presented. The application includes micro-CT, tomosynthesis and multiplexing. Chapter four is dedicated to the Argus system, the first stationary digital breast tomosynthesis imaging system. At last, conclusion is given in chapter five

    On-belt Tomosynthesis: 3D Imaging of Baggage for Security Inspection

    Get PDF
    This thesis describes the design, testing and evaluation of `On-belt Tomosynthesis' (ObT): a cost-e ective baggage screening system based on limited angle digital x-ray tomosynthesis and close-range photogrammetry. It is designed to be retro tted to existing airport conveyor-belt systems and to overcome the limitations of current systems creating a pseudo-3D imaging system by combining x-ray and optical imaging to form digital tomograms. The ObT design and set-up consists of a con guration of two x-ray sources illuminating 12 strip detectors around a conveyor belt curve forming an 180 arc. Investigating the acquired ObT x-ray images' noise sources and distortions, improvements were demonstrated using developed image correction methods. An increase of 45% in image uniformity was shown as a result, in the postcorrection images. Simulation image reconstruction of objects with lower attenuation coe cients showed the potential of ObT to clearly distinguish between them. Reconstruction of real data showed that objects of bigger attenuation di erences (copper versus perspex, rather than air versus perspex) could be observed better. The main conclusion from the reconstruction results was that the current imaging method needed further re nements, regarding the geometry registration and the image reconstruction. The simulation results con rmed that advancing the experimental method could produce better results than the ones which can currently be achieved. For the current state of ObT, a standard deviation of 2 mm in (a) the source coordinates, and 2 in (b) the detector angles does not a ect the image reconstruction results. Therefore, a low-cost single camera coordination and tracking solution was developed to replace the previously used manual measurements. Results obtained by the developed solution showed that the necessary prerequisites for the ObT image reconstruction could be addressed. The resulting standard deviation was of an average of 0.4 mm and 1 degree for (a) and (b) respectively

    Novel high performance techniques for high definition computer aided tomography

    Get PDF
    Mención Internacional en el título de doctorMedical image processing is an interdisciplinary field in which multiple research areas are involved: image acquisition, scanner design, image reconstruction algorithms, visualization, etc. X-Ray Computed Tomography (CT) is a medical imaging modality based on the attenuation suffered by the X-rays as they pass through the body. Intrinsic differences in attenuation properties of bone, air, and soft tissue result in high-contrast images of anatomical structures. The main objective of CT is to obtain tomographic images from radiographs acquired using X-Ray scanners. The process of building a 3D image or volume from the 2D radiographs is known as reconstruction. One of the latest trends in CT is the reduction of the radiation dose delivered to patients through the decrease of the amount of acquired data. This reduction results in artefacts in the final images if conventional reconstruction methods are used, making it advisable to employ iterative reconstruction algorithms. There are numerous reconstruction algorithms available, from which we can highlight two specific types: traditional algorithms, which are fast but do not enable the obtaining of high quality images in situations of limited data; and iterative algorithms, slower but more reliable when traditional methods do not reach the quality standard requirements. One of the priorities of reconstruction is the obtaining of the final images in near real time, in order to reduce the time spent in diagnosis. To accomplish this objective, new high performance techniques and methods for accelerating these types of algorithms are needed. This thesis addresses the challenges of both traditional and iterative reconstruction algorithms, regarding acceleration and image quality. One common approach for accelerating these algorithms is the usage of shared-memory and heterogeneous architectures. In this thesis, we propose a novel simulation/reconstruction framework, namely FUX-Sim. This framework follows the hypothesis that the development of new flexible X-ray systems can benefit from computer simulations, which may also enable performance to be checked before expensive real systems are implemented. Its modular design abstracts the complexities of programming for accelerated devices to facilitate the development and evaluation of the different configurations and geometries available. In order to obtain near real execution times, low-level optimizations for the main components of the framework are provided for Graphics Processing Unit (GPU) architectures. Other alternative tackled in this thesis is the acceleration of iterative reconstruction algorithms by using distributed memory architectures. We present a novel architecture that unifies the two most important computing paradigms for scientific computing nowadays: High Performance Computing (HPC). The proposed architecture combines Big Data frameworks with the advantages of accelerated computing. The proposed methods presented in this thesis provide more flexible scanner configurations as they offer an accelerated solution. Regarding performance, our approach is as competitive as the solutions found in the literature. Additionally, we demonstrate that our solution scales with the size of the problem, enabling the reconstruction of high resolution images.El procesamiento de imágenes médicas es un campo interdisciplinario en el que participan múltiples áreas de investigación como la adquisición de imágenes, diseño de escáneres, algoritmos de reconstrucción de imágenes, visualización, etc. La tomografía computarizada (TC) de rayos X es una modalidad de imágen médica basada en el cálculo de la atenuación sufrida por los rayos X a medida que pasan por el cuerpo a escanear. Las diferencias intrínsecas en la atenuación de hueso, aire y tejido blando dan como resultado imágenes de alto contraste de estas estructuras anatómicas. El objetivo principal de la TC es obtener imágenes tomográficas a partir estas radiografías obtenidas mediante escáneres de rayos X. El proceso de construir una imagen o volumen en 3D a partir de las radiografías 2D se conoce como reconstrucción. Una de las últimas tendencias en la tomografía computarizada es la reducción de la dosis de radiación administrada a los pacientes a través de la reducción de la cantidad de datos adquiridos. Esta reducción da como resultado artefactos en las imágenes finales si se utilizan métodos de reconstrucción convencionales, por lo que es aconsejable emplear algoritmos de reconstrucción iterativos. Existen numerosos algoritmos de reconstrucción disponibles a partir de los cuales podemos destacar dos categorías: algoritmos tradicionales, rápidos pero no permiten obtener imágenes de alta calidad en situaciones en las que los datos son limitados; y algoritmos iterativos, más lentos pero más estables en situaciones donde los métodos tradicionales no alcanzan los requisitos en cuanto a la calidad de la imagen. Una de las prioridades de la reconstrucción es la obtención de las imágenes finales en tiempo casi real, con el fin de reducir el tiempo de diagnóstico. Para lograr este objetivo, se necesitan nuevas técnicas y métodos de alto rendimiento para acelerar estos algoritmos. Esta tesis aborda los desafíos de los algoritmos de reconstrucción tradicionales e iterativos, con respecto a la aceleración y la calidad de imagen. Un enfoque común para acelerar estos algoritmos es el uso de arquitecturas de memoria compartida y heterogéneas. En esta tesis, proponemos un nuevo sistema de simulación/reconstrucción, llamado FUX-Sim. Este sistema se construye alrededor de la hipótesis de que el desarrollo de nuevos sistemas de rayos X flexibles puede beneficiarse de las simulaciones por computador, en los que también se puede realizar un control del rendimiento de los nuevos sistemas a desarrollar antes de su implementación física. Su diseño modular abstrae las complejidades de la programación para aceleradores con el objetivo de facilitar el desarrollo y la evaluación de las diferentes configuraciones y geometrías disponibles. Para obtener ejecuciones en casi tiempo real, se proporcionan optimizaciones de bajo nivel para los componentes principales del sistema en las arquitecturas GPU. Otra alternativa abordada en esta tesis es la aceleración de los algoritmos de reconstrucción iterativa mediante el uso de arquitecturas de memoria distribuidas. Presentamos una arquitectura novedosa que unifica los dos paradigmas informáticos más importantes en la actualidad: computación de alto rendimiento (HPC) y Big Data. La arquitectura propuesta combina sistemas Big Data con las ventajas de los dispositivos aceleradores. Los métodos propuestos presentados en esta tesis proporcionan configuraciones de escáner más flexibles y ofrecen una solución acelerada. En cuanto al rendimiento, nuestro enfoque es tan competitivo como las soluciones encontradas en la literatura. Además, demostramos que nuestra solución escala con el tamaño del problema, lo que permite la reconstrucción de imágenes de alta resolución.This work has been mainly funded thanks to a FPU fellowship (FPU14/03875) from the Spanish Ministry of Education. It has also been partially supported by other grants: • DPI2016-79075-R. “Nuevos escenarios de tomografía por rayos X”, from the Spanish Ministry of Economy and Competitiveness. • TIN2016-79637-P Towards unification of HPC and Big Data Paradigms from the Spanish Ministry of Economy and Competitiveness. • Short-term scientific missions (STSM) grant from NESUS COST Action IC1305. • TIN2013-41350-P, Scalable Data Management Techniques for High-End Computing Systems from the Spanish Ministry of Economy and Competitiveness. • RTC-2014-3028-1 NECRA Nuevos escenarios clinicos con radiología avanzada from the Spanish Ministry of Economy and Competitiveness.Programa Oficial de Doctorado en Ciencia y Tecnología InformáticaPresidente: José Daniel García Sánchez.- Secretario: Katzlin Olcoz Herrero.- Vocal: Domenico Tali