681 research outputs found

    Development of a Wearable Exoskeleton for Arm Rehabilitation

    Get PDF
    With the increasing population of aging and disabled individuals, the need for a more effective and efficient solutions is at peak, Powered Exoskeletons are wearable robots that can be attached to the disabled limb with the goal of adding power to, or rectifying the limb functionality , one of its application is rehabilitation. This study review relevant research, technologies and products, while critically analyzing them and addressing some of the current problem faced by the researchers in this field, such as the use EMG signal as a primary input to the controller. This research propose an adaptive EMG-based upper limb exoskeleton that is built on a fuzzy controller. The paper strives to propose a wearable general-user Exoskeleton, Built around an interactive gaming interface to engage the patients in the rehabilitation process. The games and exoskeleton assistance degree can be preset – on medical supervision – to different training patterns. Ultimately, the project strives to afford normal daily life for those who needs it

    A Review of Modeling and Diagnostic Techniques for Eccentricity Fault in Electric Machines

    Get PDF
    Research on the modeling and fault diagnosis of rotor eccentricities has been conducted during the past two decades. A variety of diagnostic theories and methods have been proposed based on different mechanisms, and there are reviews following either one type of electric machines or one type of eccentricity. Nonetheless, the research routes of modeling and diagnosis are common, regardless of machine or eccentricity types. This article tends to review all the possible modeling and diagnostic approaches for all common types of electric machines with eccentricities and provide suggestions on future research roadmap. The paper indicates that a reliable low-cost non-intrusive real-time online visualized diagnostic method is the trend. Observer-based diagnostic strategies are thought promising for the continued research

    Elbow exoskeleton mechanism for multistage poststroke rehabilitation.

    Get PDF
    More than three million people are suffering from stroke in England. The process of post-stroke rehabilitation consists of a series of biomechanical exercises- controlled joint movement in acute phase; external assistance in the mid phase; and variable levels of resistance in the last phase. Post-stroke rehabilitation performed by physiotherapist has many limitations including cost, time, repeatability and intensity of exercises. Although a large variety of arm exoskeletons have been developed in the last two decades to substitute the conventional exercises provided by physiotherapist, most of these systems have limitations with structural configuration, sensory data acquisition and control architecture. It is still difficult to facilitate multistage post-stroke rehabilitation to patients sited around hospital bed without expert intervention. To support this, a framework for elbow exoskeleton has been developed that is portable and has the potential to offer all three types of exercises (external force, assistive and resistive) in a single structure. The design enhances torque to weight ratio compared to joint based actuation systems. The structural lengths of the exoskeleton are determined based on the mean anthropometric parameters of healthy users and the lengths of upperarm and forearm are determined to fit a wide range of users. The operation of the exoskeleton is divided into three regions where each type of exercise can be served in a specific way depending on the requirements of users. Electric motor provides power in the first region of operation whereas spring based assistive force is used in the second region and spring based resistive force is applied in the third region. This design concept provides an engineering solution of integrating three phases of post-stroke exercises in a single device. With this strategy, the energy source is only used in the first region to power the motor whereas the other two modes of exercise can work on the stored energy of springs. All these operations are controlled by a single motor and the maximum torque of the motor required is only 5 Nm. However, due to mechanical advantage, the exoskeleton can provide the joint torque up to 10 Nm. To remove the dependency on biosensor, the exoskeleton has been designed with a hardware-based mechanism that can provide assistive and resistive force. All exoskeleton components are integrated into a microcontroller-based circuit for measuring three joint parameters (angle, velocity and torque) and for controlling exercises. A user-friendly, multi-purpose graphical interface has been developed for participants to control the mode of exercise and it can be managed manually or in automatic mode. To validate the conceptual design, a prototype of the exoskeleton has been developed and it has been tested with healthy subjects. The generated assistive torque can be varied up to 0.037 Nm whereas resistive torque can be varied up to 0.057 Nm. The mass of the exoskeleton is approximately 1.8 kg. Two comparative studies have been performed to assess the measurement accuracy of the exoskeleton. In the first study, data collected from two healthy participants after using the exoskeleton and Kinect sensor by keeping Kinect sensor as reference. The mean measurement errors in joint angle are within 5.18 % for participant 1 and 1.66% for participant 2; the errors in torque measurement are within 8.48% and 7.93% respectively. In the next study, the repeatability of joint measurement by exoskeleton is analysed. The exoskeleton has been used by three healthy users in two rotation cycles. It shows a strong correction (correlation coefficient: 0.99) between two consecutive joint angle measurements and standard deviation is calculated to determine the error margin which comes under acceptable range (maximum: 8.897). The research embodied in this thesis presents a design framework of a portable exoskeleton model for providing three modes of exercises, which could provide a potential solution for all stages of post- stroke rehabilitation

    Synchronization-Based Control of a Robotic Suit for Walking Assist

    Get PDF
    信州大学博士(工学)・学位論文・平成24年3月20日授与(甲第562号)・ZHANG XIAThesisZHANG XIA. Synchronization-Based Control of a Robotic Suit for Walking Assist. 信州大学, 2012, 153p, 博士論文doctoral thesi

    Control of Flexible Manipulators. Theory and Practice

    Get PDF

    Design of High Efficiency Brushless Permanent Magnet Machines and Driver System

    Get PDF
    The dissertation is concerned with the design of high-efficiency permanent magnet synchronous machinery and the control system. The dissertation first talks about the basic concept of the permanent magnet synchronous motor (PMSM) design and the mathematics design model of the advanced design method. The advantage of the design method is that it can increase the high load capacity at no cost of increasing the total machine size. After that, the control method of the PMSM and Permanent magnet synchronous generator (PMSG) is introduced. The design, simulation, and test of a permanent magnet brushless DC (BLDC) motor for electric impact wrench and new mechanical structure are first presented based on the design method. Finite element analysis based on the Maxwell 2D is built to optimize the design and the control board is designed using Altium Designer. Both the motor and control board have been fabricated and tested to verify the design. The electrical and mechanical design are combined, and it provides an analytical IPMBLDC design method and an innovative and reasonable mechanical dynamical calculation method for the impact wrench system, which can be used in whole system design of other functional electric tools. A 2kw high-efficiency alternator system and its control board system are also designed, analyzed and fabricated applying to the truck auxiliary power unit (APU). The alternator system has two stages. The first stage is that the alternator three-phase outputs are connected to the three-phase active rectifier to get 48V DC. An advanced Sliding Mode Observer (SMO) is used to get an alternator position. The buck is used for the second stage to get 14V DC output. The whole system efficiency is much higher than the traditional system using induction motor

    Induction Motors

    Get PDF
    AC motors play a major role in modern industrial applications. Squirrel-cage induction motors (SCIMs) are probably the most frequently used when compared to other AC motors because of their low cost, ruggedness, and low maintenance. The material presented in this book is organized into four sections, covering the applications and structural properties of induction motors (IMs), fault detection and diagnostics, control strategies, and the more recently developed topology based on the multiphase (more than three phases) induction motors. This material should be of specific interest to engineers and researchers who are engaged in the modeling, design, and implementation of control algorithms applied to induction motors and, more generally, to readers broadly interested in nonlinear control, health condition monitoring, and fault diagnosis

    Dual drive series actuator

    Get PDF
    Industrial robotic manipulators can be found in most factories today. Their tasks are accomplished through actively moving, placing and assembling parts. This movement is facilitated by actuators that apply a torque in response to a command signal. The presence of friction and possibly backlash have instigated the development of sophisticated compensation and control methods in order to achieve the desired performance may that be accurate motion tracking, fast movement or in fact contact with the environment. This thesis presents a dual drive actuator design that is capable of physically linearising friction and hence eliminating the need for complex compensation algorithms. A number of mathematical models are derived that allow for the simulation of the actuator dynamics. The actuator may be constructed using geared dc motors, in which case the benefits of torque magnification is retained whilst the increased non-linear friction effects are also linearised. An additional benefit of the actuator is the high quality, low latency output position signal provided by the differencing of the two drive positions. Due to this and the linearised nature of friction, the actuator is well suited for low velocity, stop-start applications, micro-manipulation and even in hard-contact tasks. There are, however, disadvantages to its design. When idle, the device uses power whilst many other, single drive actuators do not. Also the complexity of the models mean that parameterisation is difficult. Management of start-up conditions still pose a challenge

    Computer aided design of 3D of renewable energy platform for Togo's smart grid power system infrastructure

    Get PDF
    The global requirement for sustainable energy provision will become increasingly important over the next fifty years as the environmental effects of fossil fuel use become apparent. Therefore, the issues surrounding integration of renewable energy supplies need to be considered carefully. The focus of this work was the development of an innovative computer aided design of a 3 Dimensional renewable energy platform for Togo’s smart grid power system infrastructure. It demonstrates its validation for industrial, commercial and domestic applications. The Wind, Hydro, and PV system forming our 3 Dimensional renewable energy power generation systems introduces a new path for hybrid systems which extends the system capacities to include, a stable and constant clean energy supply, a reduced harmonic distortion, and an improved power system efficiency. Issues requiring consideration in high percentage renewable energy systems therefore includes the reliability of the supply when intermittent sources of electricity are being used, and the subsequent necessity for storage and back-up generation The adoption of Genetic algorithms in this case was much suited in minimizing the THD as the adoption of the CHB-MLI was ideal for connecting renewable energy sources with an AC grid. Cascaded inverters have also been proposed for use as the main traction drive in electric vehicles, where several batteries or ultra-capacitors are well suited to serve as separate DC sources. The simulation done in various non-linear load conditions showed the proportionality of an integral control based compensating cascaded passive filter thereby balancing the system even in non-linear load conditions. The measured total harmonic distortion of the source currents was found to be 2.36% thereby in compliance with IEEE 519-1992 and IEC 61000-3 standards for harmonics This work has succeeded in developing a more complete tool for analysing the feasibility of integrated renewable energy systems. This will allow informed decisions to be made about the technical feasibility of supply mix and control strategies, plant type, sizing and storage sizing, for any given area and range of supply options. The developed 3D renewable energy platform was examined and evaluated using CAD software analysis and a laboratory base mini test. The initial results showed improvements compared to other hybrid systems and their existing control systems. There was a notable improvement in the dynamic load demand and response, stability of the system with a reduced harmonic distortion. The derivatives of this research therefore proposes an innovative solution and a path for Togo and its intention of switching to renewable energy especially for its smart grid power system infrastructure. It demonstrates its validation for industrial, commercial and domestic applicationsN/