5,872 research outputs found
Robot Autonomy for Surgery
Autonomous surgery involves having surgical tasks performed by a robot
operating under its own will, with partial or no human involvement. There are
several important advantages of automation in surgery, which include increasing
precision of care due to sub-millimeter robot control, real-time utilization of
biosignals for interventional care, improvements to surgical efficiency and
execution, and computer-aided guidance under various medical imaging and
sensing modalities. While these methods may displace some tasks of surgical
teams and individual surgeons, they also present new capabilities in
interventions that are too difficult or go beyond the skills of a human. In
this chapter, we provide an overview of robot autonomy in commercial use and in
research, and present some of the challenges faced in developing autonomous
surgical robots
An Open-Source 7-Axis, Robotic Platform to Enable Dexterous Procedures within CT Scanners
This paper describes the design, manufacture, and performance of a highly
dexterous, low-profile, 7 Degree-of-Freedom (DOF) robotic arm for CT-guided
percutaneous needle biopsy. Direct CT guidance allows physicians to localize
tumours quickly; however, needle insertion is still performed by hand. This
system is mounted to a fully active gantry superior to the patient's head and
teleoperated by a radiologist. Unlike other similar robots, this robot's fully
serial-link approach uses a unique combination of belt and cable drives for
high-transparency and minimal-backlash, allowing for an expansive working area
and numerous approach angles to targets all while maintaining a small in-bore
cross-section of less than . Simulations verified the system's
expansive collision free work-space and ability to hit targets across the
entire chest, as required for lung cancer biopsy. Targeting error is on average
on a teleoperated accuracy task, illustrating the system's sufficient
accuracy to perform biopsy procedures. The system is designed for lung biopsies
due to the large working volume that is required for reaching peripheral lung
lesions, though, with its large working volume and small in-bore
cross-sectional area, the robotic system is effectively a general-purpose
CT-compatible manipulation device for percutaneous procedures. Finally, with
the considerable development time undertaken in designing a precise and
flexible-use system and with the desire to reduce the burden of other
researchers in developing algorithms for image-guided surgery, this system
provides open-access, and to the best of our knowledge, is the first
open-hardware image-guided biopsy robot of its kind.Comment: 8 pages, 9 figures, final submission to IROS 201
On Neuromechanical Approaches for the Study of Biological Grasp and Manipulation
Biological and robotic grasp and manipulation are undeniably similar at the
level of mechanical task performance. However, their underlying fundamental
biological vs. engineering mechanisms are, by definition, dramatically
different and can even be antithetical. Even our approach to each is
diametrically opposite: inductive science for the study of biological systems
vs. engineering synthesis for the design and construction of robotic systems.
The past 20 years have seen several conceptual advances in both fields and the
quest to unify them. Chief among them is the reluctant recognition that their
underlying fundamental mechanisms may actually share limited common ground,
while exhibiting many fundamental differences. This recognition is particularly
liberating because it allows us to resolve and move beyond multiple paradoxes
and contradictions that arose from the initial reasonable assumption of a large
common ground. Here, we begin by introducing the perspective of neuromechanics,
which emphasizes that real-world behavior emerges from the intimate
interactions among the physical structure of the system, the mechanical
requirements of a task, the feasible neural control actions to produce it, and
the ability of the neuromuscular system to adapt through interactions with the
environment. This allows us to articulate a succinct overview of a few salient
conceptual paradoxes and contradictions regarding under-determined vs.
over-determined mechanics, under- vs. over-actuated control, prescribed vs.
emergent function, learning vs. implementation vs. adaptation, prescriptive vs.
descriptive synergies, and optimal vs. habitual performance. We conclude by
presenting open questions and suggesting directions for future research. We
hope this frank assessment of the state-of-the-art will encourage and guide
these communities to continue to interact and make progress in these important
areas
Combining Differential Kinematics and Optical Flow for Automatic Labeling of Continuum Robots in Minimally Invasive Surgery
International audienceThe segmentation of continuum robots in medical images can be of interest for analyzing surgical procedures or for controlling them. However, the automatic segmentation of continuous and flexible shapes is not an easy task. On one hand conventional approaches are not adapted to the specificities of these instruments, such as imprecise kinematic models, and on the other hand techniques based on deep-learning showed interesting capabilities but need many manually labeled images. In this article we propose a novel approach for segmenting continuum robots on endoscopic images, which requires no prior on the instrument visual appearance and no manual annotation of images. The method relies on the use of the combination of kinematic models and differential kinematic models of the robot and the analysis of optical flow in the images. A cost function aggregating information from the acquired image, from optical flow and from robot encoders is optimized using particle swarm optimization and provides estimated parameters of the pose of the continuum instrument and a mask defining the instrument in the image. In addition a temporal consistency is assessed in order to improve stochastic optimization and reject outliers. The proposed approach has been tested for the robotic instruments of a flexible endoscopy platform both for benchtop acquisitions and an in vivo video. The results show the ability of the technique to correctly segment the instruments without a prior, and in challenging conditions. The obtained segmentation can be used for several applications, for instance for providing automatic labels for machine learning techniques
A Miniature 3-DoF Flexible Parallel Robotic Wrist Using NiTi Wires for Gastrointestinal Endoscopic Surgery
Gastrointestinal endoscopic surgery (GES) has high requirements for
instruments' size and distal dexterity, because of the narrow endoscopic
channel and long, tortuous human gastrointestinal tract. This paper utilized
Nickel-Titanium (NiTi) wires to develop a miniature 3-DoF
(pitch-yaw-translation) flexible parallel robotic wrist (FPRW). Additionally,
we assembled an electric knife on the wrist's connection interface and then
teleoperated it to perform an endoscopic submucosal dissection (ESD) on porcine
stomachs. The effective performance in each ESD workflow proves that the
designed FPRW has sufficient workspace, high distal dexterity, and high
positioning accuracy.Comment: IEEE International Conference on Robotics and Automation (ICRA) 2022
workshop: Frontiers of Endoluminal Intervention: Clinical opportunities and
technical challenge
Adoption of vehicular ad hoc networking protocols by networked robots
This paper focuses on the utilization of wireless networking in the robotics domain. Many researchers have already equipped their robots with wireless communication capabilities, stimulated by the observation that multi-robot systems tend to have several advantages over their single-robot counterparts. Typically, this integration of wireless communication is tackled in a quite pragmatic manner, only a few authors presented novel Robotic Ad Hoc Network (RANET) protocols that were designed specifically with robotic use cases in mind. This is in sharp contrast with the domain of vehicular ad hoc networks (VANET). This observation is the starting point of this paper. If the results of previous efforts focusing on VANET protocols could be reused in the RANET domain, this could lead to rapid progress in the field of networked robots. To investigate this possibility, this paper provides a thorough overview of the related work in the domain of robotic and vehicular ad hoc networks. Based on this information, an exhaustive list of requirements is defined for both types. It is concluded that the most significant difference lies in the fact that VANET protocols are oriented towards low throughput messaging, while RANET protocols have to support high throughput media streaming as well. Although not always with equal importance, all other defined requirements are valid for both protocols. This leads to the conclusion that cross-fertilization between them is an appealing approach for future RANET research. To support such developments, this paper concludes with the definition of an appropriate working plan
An Intervening Ethical Governor for a Robot Mediator in Patient-Caregiver Relationships
© Springer International Publishing AG 2015DOI: 10.1007/978-3-319-46667-5_6Patients with Parkinson’s disease (PD) experience challenges when interacting with
caregivers due to their declining control over their musculature. To remedy those challenges, a
robot mediator can be used to assist in the relationship between PD patients and their caregivers.
In this context, a variety of ethical issues can arise. To overcome one issue in particular,
providing therapeutic robots with a robot architecture that can ensure patients’ and caregivers’
dignity is of potential value. In this paper, we describe an intervening ethical governor for a
robot that enables it to ethically intervene, both to maintain effective patient–caregiver
relationships and prevent the loss of dignity
- …