    Generic, Geometric Finite Element Analysis of the Transtibial Residual Limb and Prosthetic Socket

    Get PDF
    Finite element analysis was used to investigate the stress distribution between the residual limb and prosthetic socket of persons with transtibial amputation (TTA). The purpose of this study was to develop a tool to provide a quantitative estimate of prosthetic interface pressures to improve our understanding of residual limb/prosthetic socket biomechanics and prosthetic fit. FE models of the residual limb and prosthetic socket were created. In contrast to previous FE models of the prosthetic socket/residual limb system, these models were not based on the geometry of a particular individual, but instead were based on a generic, geometric approximation of the residual limb. These models could then be scaled for the limbs of specific individuals. The material properties of the bulk soft tissues of the residual limb were based upon local in vivo indentor studies. Significant effort was devoted toward the validation of these generic, geometric FE models; prosthetic interface pressures estimated via the FE model were compared to experimentally determined interface pressures for several persons with TTA in a variety of socket designs and static load/alignment states. The FE normal stresses were of the same order of magnitude as the measured stresses (0-200 kPa); however, significant differences in the stress distribution were observed. Although the generic, geometric FE models do not appear to accurately predict the stress distribution for specific subjects, the models have practical applications in comparative stress distribution studies

    Preliminary results on the effects of orthopedic implant stiffness fixed to the cut end of the femur on the stress at the stump-prosthetic interface

    Get PDF
    A lot of trans-femoral amputation patients experience skin breakdown due to the pressures and shear stresses in the stump-prosthesis interface. In this study, a finite element model was employed to investigate the stresses at the stump interface in the case of an orthopedic implant fixed to the cut end of the femur. By changing the stiffness of this implant, we aim to see how the stiffness of this implant affects the stresses in the interface between the amputated limb and the prosthesis. To find out the effects of implant stiffness, five values for the elastic modulus, ranging from 0.1 to 0.5 Mpa, with an interval of 0.1 Mpa were employed in the implant structure of the FE model. Obtained results show that the implant played important role in reducing the stresses at the stump-prosthesis interface where the contact pressure did not exceed 53 Kpa and 17.3 Kpa for shear stress in the stiffer case of an implant, while the contact pressure in the case of femur without implant exceeded 79Kpa and 42 Kpa for shear stress. We also noted that the intensity of the contact pressure and the shear stress is proportional to the stiffness of the implant, as the greater the implant stiffness, the higher the peak of these stresses

    Nonlinear Elastic Material Property Estimation of Lower Extremity Residual Limb Tissues

    Get PDF
    The interface stresses between the residual limb and prosthetic socket have been studied to investigate prosthetic fit. Finite-element models of the residual limb-prosthetic socket interface facilitate investigation of the mechanical interface and may serve as a potential tool for future prosthetic socket design. However, the success of such residual limb models to date has been limited, in large part due to inadequate material formulations used to approximate the mechanical behavior of residual limb soft tissues. Nonlinear finite-element analysis was used to simulate force-displacement data obtained during in vivo rate-controlled (1, 5, and 10 mm/s) cyclic indentation of the residual limb soft tissues of seven individuals with transtibial amputation. The finite-element models facilitated determination of an appropriate set of nonlinear elastic material coefficients for bulk soft tissue at discrete clinically relevant test locations. Axisymmetric finite-element models of the residual limb bulk soft tissue in the vicinity of the test location, the socket wall and the indentor tip were developed incorporating contact analysis, large displacement, and large strain, and the James-Green-Simpson nonlinear elastic material formulation. Model dimensions were based on medical imaging studies of the residual limbs. The material coefficients were selected such that the normalized sum of square error (NSSE) between the experimental and finite-element model indentor tip reaction force was minimized. A total of 95% of the experimental data were simulated using the James-Green-Simpson material formulation with an NSSE less than 5%. The respective James-Green-Simpson material coefficients varied with subject, test location, and indentation rate. Therefore, these coefficients cannot be readily extrapolated to other sites or individuals, or to the same site and individual some time after testing

    A Review of Prosthetic Interface Stress Investigations

    Get PDF
    Over the last decade, numerous experimental and numerical analyses have been conducted to investigate the stress distribution between the residual limb and prosthetic socket of persons with lower limb amputation. The objectives of these analyses have been to improve our understanding of the residual limb/prosthetic socket system, to evaluate the influence of prosthetic design parameters and alignment variations on the interface stress distribution, and to evaluate prosthetic fit. The purpose of this paper is to summarize these experimental investigations and identify associated limitations. In addition, this paper presents an overview of various computer models used to investigate the residual limb interface, and discusses the differences and potential ramifications of the various modeling formulations. Finally, the potential and future applications of these experimental and numerical analyses in prosthetic design are presented

    A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations

    Get PDF
    An alternative solution to conventional stumpā€“socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Gƶteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, LĆ¼beck, Germany) on bone failure and stemā€“bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants

    Parametric Analysis Using the Finite Element Method to Investigate Prosthetic Interface Stresses for Persons with Trans-tibial Amputation

    Get PDF
    A finite element (FE) model of the below-knee residual limb and prosthetic socket was created to investigate the effects of parameter variations on the interface stress distribution during static stance. This model was based upon geometric approximations of anthropometric residual limb geometry. The model was not specific to an individual with amputation, but could be scaled to approximate the limb of a particular subject. Parametric analyses were conducted to investigate the effects of prosthetic socket design and residual limb geometry on the residual limb/prosthetic socket interface stresses. Behavioral trends were illustrated via sensitivity analysis. The results of the parametric analyses indicate that the residual limb/prosthetic socket interface stresses are affected by variations in both prosthetic design and residual limb geometry. Specifically, the analyses indicate : 1) the residual limb/prosthetic liner interface pressures are relatively insensitive to the socket stiffness ; 2) the stiffness of the prosthetic liner influences the interface stress distribution for both the unrectified and patellar-tendon-bearing (PTB) rectified models-- the external load state appears to influence the interface pressure distribution, while the prosthetic socket rectification appears to influence the interface shear stress distribution ; 3) the interface pressures are - very sensitive to the prosthetic rectification ; 4) the shape and relative bulk of soft tissue may significantly influence the interface pressure distribution ; 5) the interface pressure distribution is also influenced by the residual limb length; and 6) the stiffness/compliance of the residual limb soft tissues may significantly alter the interface pressure distribution

    AN APPROACH FOR QUANTITATIVE EVALUATION OF TRANSFEMORAL PROSTHESIS SOCKET BY FINITE ELEMENT ANALYSIS

    Get PDF
    Objective: The correct shaping of the socket for appropriate load distribution is a critical process in the design of lower limb prosthesis sockets.Several studies have been conducted to disclose these parameters; they can be divided into two methods: Experiment method and computationmethod. The finite element (FE) analysis has highly effective for study the interface pressure between the residual limb and socket. However, there isa little study focus on creating separate models of the socket and residual limb. Almost research using the same shape of socket and residual limb orusing the unreal model of the socket. This study will be given some solutions for the above issues.Methods: The author creates two models of the residual limb: Same and different with the shape of the socket. After that, the FE models weregenerated with appropriate conditions of the donning process. The experimental procedure was conducted for comparison and discussion with theresults of the simulation.Results: The results in case of different shape of socket and residual limb suggest that it is the better model for evaluating the interface pressure.Conclusions: The procedure developed through this work can be used by future researchers and prosthesis designers in understanding how to betterdesign the socket and transfemoral prostheses

    Predicting Pressure Distribution Between Transfemoral Prosthetic Socket and Residual Limb Using Finite Element Analysis

    Get PDF
    In this study, a non-linear Finite Element (FE) model was created and analyzed to determine the pressure distribution between the residual limb and the prosthetic socket of a transfemoral amputee. This analysis was performed in an attempt to develop a process allowing healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics to reduce the number of re-fittings needed for the amputees. The analysis considered the effects of interference due to insertion of the limb into the prosthesis, referred to as donning, and also the effects due to the body weight of the amputee. A non-linear finite element static implicit analysis method was utilized. This analysis implemented multiple finite element techniques, including geometric non-linearity due to large deflections, non-linear contacts due to friction between the contact surfaces of the residual limb and the socket, and non-linear hyper-elastic material properties for the residual limbā€™s soft tissue. This non-linear static analysis was carried out in two time-steps. The first step involved solving the interference fit analysis to study the pre-stresses developed due to the effect of donning. The donning process results in soft tissue displacement to accommodate the internal geometry of the prosthesis. In the second load application time-step, an additional load of half the personā€™s body weight was applied to the femur. The maximum normal stress (contact pressure) of 84 kPa was observed due to the combined effect of the donning procedure and body weight application, comparable to the studies performed by other researchers. The procedure developed through this work can be used by future researchers and prosthetic designers in understanding how to better design transfemoral prosthesis