349 research outputs found

    Enhanced Digital Breast Tomosynthesis diagnosis using 3D visualization and automatic classification of lesions

    Get PDF
    Breast cancer represents the main cause of cancer-related deaths in women. Nonetheless, the mortality rate of this disease has been decreasing over the last three decades, largely due to the screening programs for early detection. For many years, both screening and clinical diagnosis were mostly done through Digital Mammography (DM). Approved in 2011, Digital Breast Tomosynthesis (DBT) is similar to DM but it allows a 3D reconstruction of the breast tissue, which helps the diagnosis by reducing the tissue overlap. Currently, DBT is firmly established and is approved as a stand-alone modality to replace DM. The main objective of this thesis is to develop computational tools to improve the visualization and interpretation of DBT data. Several methods for an enhanced visualization of DBT data through volume rendering were studied and developed. Firstly, important rendering parameters were considered. A new approach for automatic generation of transfer functions was implemented and two other parameters that highly affect the quality of volume rendered images were explored: voxel size in Z direction and sampling distance. Next, new image processing methods that improve the rendering quality by considering the noise regularization and the reduction of out-of-plane artifacts were developed. The interpretation of DBT data with automatic detection of lesions was approached through artificial intelligence methods. Several deep learning Convolutional Neural Networks (CNNs) were implemented and trained to classify a complete DBT image for the presence or absence of microcalcification clusters (MCs). Then, a faster R-CNN (region-based CNN) was trained to detect and accurately locate the MCs in the DBT images. The detected MCs were rendered with the developed 3D rendering software, which provided an enhanced visualization of the volume of interest. The combination of volume visualization with lesion detection may, in the future, improve both diagnostic accuracy and also reduce analysis time. This thesis promotes the development of new computational imaging methods to increase the diagnostic value of DBT, with the aim of assisting radiologists in their task of analyzing DBT volumes and diagnosing breast cancer

    Modern Breast Cancer Detection: A Technological Review

    Get PDF
    Breast cancer is a serious threat worldwide and is the number two killer of women in the United States. The key to successful management is screening and early detection. What follows is a description of the state of the art in screening and detection for breast cancer as well as a discussion of new and emerging technologies. This paper aims to serve as a starting point for those who are not acquainted with this growing field

    Stand-Alone Artificial Intelligence for Breast Cancer Detection in Mammography: Comparison With 101 Radiologists.

    Get PDF
    BACKGROUND: Artificial intelligence (AI) systems performing at radiologist-like levels in the evaluation of digital mammography (DM) would improve breast cancer screening accuracy and efficiency. We aimed to compare the stand-alone performance of an AI system to that of radiologists in detecting breast cancer in DM. METHODS: Nine multi-reader, multi-case study datasets previously used for different research purposes in seven countries were collected. Each dataset consisted of DM exams acquired with systems from four different vendors, multiple radiologists' assessments per exam, and ground truth verified by histopathological analysis or follow-up, yielding a total of 2652 exams (653 malignant) and interpretations by 101 radiologists (28 296 independent interpretations). An AI system analyzed these exams yielding a level of suspicion of cancer present between 1 and 10. The detection performance between the radiologists and the AI system was compared using a noninferiority null hypothesis at a margin of 0.05. RESULTS: The performance of the AI system was statistically noninferior to that of the average of the 101 radiologists. The AI system had a 0.840 (95% confidence interval [CI] = 0.820 to 0.860) area under the ROC curve and the average of the radiologists was 0.814 (95% CI = 0.787 to 0.841) (difference 95% CI = -0.003 to 0.055). The AI system had an AUC higher than 61.4% of the radiologists. CONCLUSIONS: The evaluated AI system achieved a cancer detection accuracy comparable to an average breast radiologist in this retrospective setting. Although promising, the performance and impact of such a system in a screening setting needs further investigation

    Impact of total variation minimization in volume rendering visualization of breast tomosynthesis data

    Get PDF
    Background and objective: Total Variation (TV) minimization algorithms have achieved great attention due to the virtue of decreasing noise while preserving edges. The purpose of this work is to implement and evaluate two TV minimization methods in 3D. Their performance is analyzed through 3D visualization of digital breast tomosynthesis (DBT) data with volume rendering. Methods: Both filters were studied with real phantom and one clinical DBT data. One algorithm was applied sequentially to all slices and the other was applied to the entire volume at once. The suitable Lagrange multiplier used in each filter equation was studied to reach the minimum 3D TV and the maximum contrast-to-noise ratio (CNR). Imaging blur was measured at 0° and 90° using two disks with different diameters (0.5 mm and 5.0 mm) and equal thickness. The quality of unfiltered and filtered data was analyzed with volume rendering at 0° and 90°. Results: For phantom data, with the sequential filter, a decrease of 25% in 3D TV value and an increase of 19% and 30% in CNR at 0° and 90°, respectively, were observed. When the filter is applied directly in 3D, TV value was reduced by 35% and an increase of 36% was achieved both for CNR at 0° and 90°. For the smaller disk, variations of 0% in width at half maximum (FWHM) at 0° and a decrease of about 2.5% for FWHM at 90° were observed for both filters. For the larger disk, there was a 2.5% increase in FWHM at 0° for both filters and a decrease of 6.28% and 1.69% in FWHM at 90° with the sequential filter and the 3D filter, respectively. When applied to clinical data, the performance of each filter was consistent with that obtained with the phantom. Conclusions: Data analysis confirmed the relevance of these methods in improving quality of DBT images. Additionally, this type of 3D visualization showed that it may play an important complementary role in DBT imaging. It allows to visualize all DBT data at once and to analyze properly filters applied to all the three dimensions

    A new challenge in Radiology: Radiomics in breast cancer diagnostics

    Get PDF
    Breast cancer is one of the most common and widespread cancers that women can have. In order to prevent the occurrence of cancer, it is important to perform a preventive examination, which includes ultrasound and mammography. Radiology as a branch of medicine has seen rapid development in recent decades thanks to the development of technology, and artificial intelligence is increasingly used in radiology. Radiomics is a new method of radiological image processing that uses software programs to analyse tissue during diagnostic imaging. It is a combination of multiple imaging modalities with the aim of highlighting pathological formations that are not visible to the naked eye or are less significant. The aim of the paper is to introduce to the readers with radiomics and to explain in more detail how it works, and how it was integrated into certain radiological diagnostics and greatly facilitated the image processing process and the diagnosis of breast cancer. Many studies have confirmed that radiomics is a method with numerous advantages, but like any new field, it has its drawbacks. The main limitation is the computer system, which must be standardised so that radiomic data processing can be used in all institutions and so that these institutions can exchange information with each other without difficulty. The problem is also false positive findings, which greatly increase the costs of institutions and the time it takes for patients to reach a diagnosis. The solution to these allegations is the development of new computer algorithms and an increase in the sensitivity of computer detection of lesions. Radiomics will certainly play an important role in diagnostics and image analysis over a period of time. Given that artificial intelligence is still in the process of development, radiomics may not have an independent application, but it will certainly make the work of doctors easier in the analysis of radiological images

    Computer-Aided Detection of Breast Cancer – Have All Bases Been Covered?

    Get PDF
    The use of computer-aided detection (CAD) systems in mammography has been the subject of intense research for many years. These systems have been developed with the aim of helping radiologists to detect signs of breast cancer. However, the effectiveness of CAD systems in practice has sparked recent debate. In this commentary, we argue that computer-aided detection will become an increasingly important tool for radiologists in the early detection of breast cancer, but there are some important issues that need to be given greater focus in designing CAD systems if they are to reach their full potential
    corecore