11,317 research outputs found

    Malignancy risk analysis in patients with inadequate fine needle aspiration cytology (FNAC) of the thyroid

    Get PDF
    Background Thyroid fine needle aspiration cytology (FNAC) is the standard diagnostic modality for thyroid nodules. However, it has limitations among which is the incidence of non-diagnostic results (Thy1). Management of cases with repeatedly non-diagnostic FNAC ranges from simple observation to surgical intervention. We aim to evaluate the incidence of malignancy in non-diagnostic FNAC, and the success rate of repeated FNAC. We also aim to evaluate risk factors for malignancy in patients with non-diagnostic FNAC. Materials and Methods Retrospective analyses of consecutive cases with thyroid non diagnostic FNAC results were included. Results Out of total 1657 thyroid FNAC done during the study period, there were 264 (15.9%) non-diagnostic FNAC on the first attempt. On repeating those, the rate of a non-diagnostic result on second FNAC was 61.8% and on third FNAC was 47.2%. The overall malignancy rate in Thy1 FNAC was 4.5% (42% papillary, 42% follicular and 8% anaplastic), and the yield of malignancy decreased considerably with successive non-diagnostic FNAC. Ultrasound guidance by an experienced head neck radiologist produced the lowest non-diagnostic rate (38%) on repetition compared to US guidance by a generalist radiologist (65%) and by non US guidance (90%). Conclusions There is a low risk of malignancy in patients with a non-diagnostic FNAC result, commensurate to the risk of any nodule. The yield of malignancy decreased considerably with successive non-diagnostic FNAC

    Thyroglobulin measurement in the washout of fine needle aspirates for the diagnosis of suspicious cervical lymph nodes

    Get PDF
    Ultrasound-guided fine-needle aspiration cytology (FNAC) for suspicious cervical lymph nodes (CLN) is the gold standard technique for the identification of metastases from differentiated thyroid carcinomas. Thyroglobulin protein (Tgp) assay in the washout of needles employed for FNA biopsies (FNAB) has been reported to refine and support FNAC performances, especially in cases of inadequate sampling or cystic lymph nodes. In the present work, we evaluated the usefulness of routine measurement of Tgp in the FNAB washout of suspicious cervical lymph nodes (CLN), and its ability to increase the FNAC accuracy in the diagnosis of metastatic CLN. A case study of 45 CLN with histological diagnosis from 36 patients was analyzed. Histology showed metastases from papillary thyroid carcinomas (PTC) in 31 CLN, from anaplastic thyroid cancer (ATC) in 3 CLN, from medullary thyroid cancer (MTC) in 4 CLN, and metastases from extrathyroidal malignancies in 5 CLN. Two CLN analyzed were found to be non-neoplastic. The overall accuracy of FNAC was 82.9%, and that of Tgp was 91.1%, not statistically different. However, Tgp determination was found essential in 4 cases of metastatic CLN from DTC with inadequate cytology, and in 1 case in which the FNAC provided a false negative result. We demonstrated that FNAC and Tgp assay show similar diagnostic accuracies, and that Tgp measurement may represent the only available information in case of inadequate lymph node sampling or cystic lymph nodes

    Detection rate of FNA cytology in medullary thyroid carcinoma. a meta-analysis

    Get PDF
    Background: The early detection of medullary thyroid carcinoma (MTC) can improve patient prognosis, because histological stage and patient age at diagnosis are highly relevant prognostic factors. As a consequence, delay in the diagnosis and/or incomplete surgical treatment should correlate with a poorer prognosis for patients. Few papers have evaluated the specific capability of fine-needle aspiration cytology (FNAC) to detect MTC, and small series have been reported. This study conducts a meta-analysis of published data on the diagnostic performance of FNAC in MTC to provide more robust estimates. Research Design and Methods: A comprehensive computer literature search of the PubMed/MEDLINE, Embase and Scopus databases was conducted by searching for the terms 'medullary thyroid' AND 'cytology', 'FNA', 'FNAB', 'FNAC', 'fine needle' or 'fine-needle'. The search was updated until 21 March 2014, and no language restrictions were used. Results: Fifteen relevant studies and 641 MTC lesions that had undergone FNAC were included. The detection rate (DR) of FNAC in patients with MTC (diagnosed as 'MTC' or 'suspicious for MTC') on a per lesion-based analysis ranged from 12·5% to 88·2%, with a pooled estimate of 56·4% (95% CI: 52·6-60·1%). The included studies were statistically heterogeneous in their estimates of DR (I-square >50%). Egger's regression intercept for DR pooling was 0·03 (95% CI: -3·1 to 3·2, P = 0·9). The study that reported the largest MTC series had a DR of 45%. Data on immunohistochemistry for calcitonin in diagnosing MTC were inconsistent for the meta-analysis. Conclusions: The presented meta-analysis demonstrates that FNAC is able to detect approximately one-half of MTC lesions. These findings suggest that other techniques may be needed in combination with FNAC to diagnose MTC and avoid false negative results. © 2014 John Wiley & Sons Ltd

    CORRELATION OF FINE NEEDLE ASPIRATION AND FINAL HISTOPATHOLOGY IN THYROID DISEASE: A SERIES OF 702 PATIENTS MANAGED IN AN ENDOCRINE SURGICAL UNIT

    Get PDF
    Thyroid nodules are a common clinical entity found among the adult general population. With increasing use of imaging investigations like ultrasonography, there has been a significant rise in the detection of non-palpable thyroid nodules that require further evaluation and management. The routine use of FNAC has reduced the number of unnecessary surgical procedures for thyroid nodules. Taking a decision as to whether to operate on a thyroid nodule is dependent on accurate FNAC testing. This study describes the experience with FNAC in a consecutive series of patients with thyroid nodules who underwent thyroidectomy at a tertiary care hospital in the department of endocrine surgery. 

    Galectin-3 performance in histologic and cytologic assessment of thyroid nodules. A systematic review and meta-analysis

    Get PDF
    The literature on Galectin-3 (Gal-3) was systematically reviewed to achieve more robust information on its histologic reliability in identifying thyroid cancers and on the concordance between Gal-3 test in histologic and cytologic samples. A computer search of the PubMed and Scopus databases was conducted by combinations of the terms thyroid and Gal-3. Initially, 545 articles were found and, after their critical review, 52 original papers were finally included. They reported 8172 nodules with histologic evaluation of Gal-3, of which 358 with also preoperative FNAC Gal-3 assessment. At histology, Gal-3 sensitivity was 87% (95% confidence intervals [CI] from 86% to 88%), and specificity 87% (95% CI from 86% to 88%); in both cases, we found heterogeneity (I285% and 93%, respectively) and significant publication bias (p < 0.001). The pooled rate of positive Gal-3 at fine needle aspiration (FNAC) among cancers with histologically proven Gal-3 positivity was 94% (95% CI from 89% to 97%), with neither heterogeneity (I214.5%) nor bias (p = 0.086). These data show high reliability of Gal-3 for thyroid cancer at histology, while its sensitivity on FNAC samples is lower. The limits of cytologic preparations and interpretation of Gal-3 results have to be solved

    The efficacy of lymph node fine needle aspiration cytology

    Get PDF
    Fine needle aspiration cytology (FNAC) of lymph nodes is a safe, easy, cheap and quick diagnostic tool, which involves the examination of a random sample of cells from a lymph node. To assess the distribution of diagnostic categories and the efficacy of lymph node fine needle aspiration cytology at our institution. These were compared to the literature. Methodology: All of lymph node FNAC cases taken between the 1st January 2012 and the 31st December 2013 were retrieved from our Laboratory Information System. A total of 300 cases were retrieved and then placed into one of six categories; Category 1: Non-diagnostic, 2: Reactive, 3: Probably reactive but lymphoma cannot be excluded, 4: Non-Hodgkin lymphoma, 5: Hodgkin lymphoma, and 6: Metastasis. These were then correlated with the histology of the lymph node excision specimens. The proportion of diagnoses placed under categories 1, 2, 3, 4, 5 and 6 represent 14%, 53%, 4.3%, 5.7%, 1.7% and 21.3% of the total respectively. The overall efficacy of FNAC showed a sensitivity of 84.5%, specificity of 99.3%, a false negative rate of 10%, a false positive rate of 0.7%, accuracy of 93.1%, positive predictive value of 98.8% and negative predictive value of 89.9%. FNAC of lymph nodes is a very useful and effective tool in triaging patients with lymphadenopathy.peer-reviewe

    Role of Fine Needle Aspiration Cytology in Salivary Gland Pathology and its Histopathological Correlation: A Two Year Prospective Study in Western India.

    Get PDF
    Background and objectives: Salivary gland lesions account for 2-6.5% of all the neoplasms of the head and neck. Fine needle aspiration cytology (FNAC) is being increasingly used in the diagnosis of salivary gland lesions. The objective of this study was to evaluate the diagnostic accuracy and the sensitivity and specificity of FNAC in various salivary gland lesions in correlation with their histopathology, which helps in the appropriate therapeutic management. Methods: A total of 120 FNACs were done on salivary gland tumours from July 2010 to June 2012 in the Department of Pathology, P.D.U. Government Medical College, Rajkot (Gujarat, India). Formalin fixed (10%), surgically resected specimens were received, they were processed and slides were prepared for histopathological diagnosis. The stained cytological and histopathological slides were studied, analyzed and correlated. Results: The cytomorphological features were studied and analyzed and the following lesions were observed: Pleomorphic adenoma (88), Warthin’s tumour (2), Cystic lesion (4), Mucoepidermoid carcinoma (6), Acinic cell carcinoma (2), Primary lymphoma (2), Carcinoma EX pleomorphic adenoma(4), metastatic malignancy deposits (2), benign parotid tumour (8) and malignant tumour (unspecified)(2). A histopathological correlation was available in 78 cases. Out of these, 71 cases were true positive, 1 was false positive, 2 were false negative and 4 were true negative. Interpretation and conclusion: The overall sensitivity, specificity and the diagnostic accuracy were 97%, 80% and 92% respectively. Hence, the appropriate therapeutic management could be planned earlier. This study documents that FNAC of the salivary gland tumours is accurate, simple, rapid, inexpensive, well tolerated and harmless for the patient

    Emperipolesis in a Case of Adult T Cell Lymphoblastic Lymphoma (Mediastinal type)-Detected at FNAC and Imprint Cytology

    Get PDF
    Emperipolesis is a condition in which viable hematopoetic cells are seen intact in the cytoplasm of host cell without damage. This phenomenon is seen in many physiologic and pathologic conditions, its presence in Rosai Dorfman disease (RDD) is characteristic of the disease. However emperipolesis is an uncommon finding in malignant lymphoma both Hodgkins and non-Hodgkin’s lymphoma, wherein it has been described in bone marrow aspirate and tissue culture. In contrast there are only two case reports of emperipolesis phenomenon described in non-Hodgkin’s lymphoma in tissue sections. We report a case of an adult T cell lymphoblastic lymphoma (mediastinal type) with features of emperipolesis demonstrated at fine needle aspiration cytology (FNAC) and imprint cytology of cervical lymph nodes. To our knowledge, this is the first case report of emperipolesis in a case of adult T cell lymphoblastic lymphoma (mediastinal type)-detected at FNAC and imprint cytology

    Lymph Node Thyroglobulin Measurement in Diagnosis of Neck Metastases of Differentiated Thyroid Carcinoma

    Get PDF
    Aim. Enlarged cervical lymph nodes (LNs) in patients with thyroid cancer are usually assessed by fine-needle aspiration cytology (FNAC). Thyroglobulin (Tg) is frequently elevated in malignant FNAC needle wash specimens (FNAC-Tg). The objectives of the study were to (1) determine an appropriate diagnostic cut-off for FNAC-Tg levels (2) compare FNAC and FNAC-Tg results in a group of 108 patients affected by differentiated thyroid carcinoma (DTC). Methods. A total of 126 consecutive FNACs were performed on enlarged LNs and the final diagnosis was confirmed by surgical pathology examination or clinical follow-up. The best FNAC-Tg cut-off level was selected by receiver operating curve analysis, and diagnostic performances of FNAC and FNAC-Tg were compared. Results. The rate of FNAC samples adequate for cytological examination was 77% in contrast FNAC-Tg available in 100% of aspirates (<.01). The sensitivity, specificity, and accuracy of FNAC were 71%, 80%, 74%, 100%, 80%, and 94%, respectively. The most appropriate cut-off value for the diagnosis of thyroid cancer metastatic LN was 1.1 ng/mL (sensitivity 100%, specificity 100%). Conclusions. The diagnostic performance of needle washout FNAC-Tg measurement with a cut-off of 1.1 ng/mL compared favorably with cytology in detecting DTC node metastases

    Predictivity of clinical, laboratory and imaging findings in diagnostic definition of palpable thyroid nodules. A multicenter prospective study

    Get PDF
    Abstract PURPOSE: To assess the role of clinical, biochemical, and morphological parameters, as added to cytology, for improving pre-surgical diagnosis of palpable thyroid nodules. METHODS: Patients with a palpable thyroid nodule were eligible if surgical intervention was indicated after a positive or suspicious for malignancy FNAC (TIR 4-5 according to the 2007 Italian SIAPEC-IAP classification), or two inconclusive FNAC at a 653 months interval, or a negative FNAC associated with one or more risk factor. Reference standard was histological malignancy diagnosis. Likelihood ratios of malignancy, sensitivity, specificity, negative (NPV), and positive predictive value (PPV) were described. Multiple correspondence analysis (MCA) and logistic regression were applied. RESULTS: Cancer was found in 433/902 (48%) patients. Considering TIR4-5 only as positive cytology, specificity, and PPV were high (94 and 91%) but sensitivity and NPV were low (61 and 72%); conversely, including TIR3 among positive, sensitivity and NPV were higher (88 and 82%) while specificity and PPV decreased (52 and 63%). Ultrasonographic size 653\u2009cm was independently associated with benignity among TIR2 cases (OR of malignancy 0.37, 95% CI 0.18-0.78). In TIR3 cases the hard consistency of small nodules was associated with malignity (OR: 3.51, 95% CI 1.84-6.70, p\u2009<\u20090.001), while size alone, irrespective of consistency, was not diagnostically informative. No other significant association was found in TIR2 and TIR3. CONCLUSIONS: The combination of cytology with clinical and ultrasonographic parameters may improve diagnostic definition of palpable thyroid nodules. However, the need for innovative diagnostic tools is still high
    corecore