481 research outputs found

    Data Analytics and Wide-Area Visualization Associated with Power Systems Using Phasor Measurements

    Get PDF
    As power system research becomes more data-driven, this study presents a framework for the analysis and visualization of phasor measurement unit (PMU) data obtained from large, interconnected systems. The proposed framework has been implemented in three steps: (a) large-scale, synthetic PMU data generation: conducted to generate research-based measurements with the inclusion of features associated with industry-grade PMU data; (b) error and event detection: conducted to assess risk levels and data accuracy of phasor measurements, and furthermore search for system events or disturbances; (c) oscillation mode visualization: conducted to present wide-area, modal information associated with large-scale power grids. To address the challenges due to real data confidentiality, the creation of realistic, synthetic PMU measurements is proposed for research use. First, data error propagation models are generated after a study of some of the issues associated with the unique time-synchronization feature of PMUs. An analysis of some of the features of real PMU data is performed to extract some of the statistics associated with data errors. Afterwards, an approach which leverages on existing, large-scale, synthetic networks to model the constantly-changing dynamics often observed in real measurements is used to generate an initial synthetic dataset. Further inclusion of PMU-related data anomalies ensures the production of realistic, synthetic measurements fit for research purposes. An application of different techniques based on a moving-window approach is suggested for use in the detection of events in real and synthetic PMU measurements. These fast methods rely on smaller time-windows to assess fewer measurement samples for events, classify disturbances into global or local events, and detect unreliable measurement sources. For large-scale power grids with complex dynamics, a distributed error analysis is proposed for the isolation of local dynamics prior any reliability assessment of PMU-obtained measurements. Finally, fundamental system dynamics which are inherent in complex, interconnected power systems are made apparent through a wide-area visualization of large-scale, electric grid oscillation modes. The approach ensures a holistic interpretation of modal information given that large amounts of modal data are often generated in these complex systems irrespective of the technique that is used

    Wide-area monitoring and control of future smart grids

    No full text
    Application of wide-area monitoring and control for future smart grids with substantial wind penetration and advanced network control options through FACTS and HVDC (both point-to-point and multi-terminal) is the subject matter of this thesis. For wide-area monitoring, a novel technique is proposed to characterize the system dynamic response in near real-time in terms of not only damping and frequency but also mode-shape, the latter being critical for corrective control action. Real-time simulation in Opal-RT is carried out to illustrate the effectiveness and practical feasibility of the proposed approach. Potential problem with wide-area closed-loop continuous control using FACTS devices due to continuously time-varying latency is addressed through the proposed modification of the traditional phasor POD concept introduced by ABB. Adverse impact of limited bandwidth availability due to networked communication is established and a solution using an observer at the PMU location has been demonstrated. Impact of wind penetration on the system dynamic performance has been analyzed along with effectiveness of damping control through proper coordination of wind farms and HVDC links. For multi-terminal HVDC (MTDC) grids the critical issue of autonomous power sharing among the converter stations following a contingency (e.g. converter outage) is addressed. Use of a power-voltage droop in the DC link voltage control loops using remote voltage feedback is shown to yield proper distribution of power mismatch according to the converter ratings while use of local voltages turns out to be unsatisfactory. A novel scheme for adapting the droop coefficients to share the burden according to the available headroom of each converter station is also studied. The effectiveness of the proposed approaches is illustrated through detailed frequency domain analysis and extensive time-domain simulation results on different test systems

    Electromechanical Dynamics of High Photovoltaic Power Grids

    Get PDF
    This dissertation study focuses on the impact of high PV penetration on power grid electromechanical dynamics. Several major aspects of power grid electromechanical dynamics are studied under high PV penetration, including frequency response and control, inter-area oscillations, transient rotor angle stability and electromechanical wave propagation.To obtain dynamic models that can reasonably represent future power systems, Chapter One studies the co-optimization of generation and transmission with large-scale wind and solar. The stochastic nature of renewables is considered in the formulation of mixed-integer programming model. Chapter Two presents the development procedures of high PV model and investigates the impact of high PV penetration on frequency responses. Chapter Three studies the impact of PV penetration on inter-area oscillations of the U.S. Eastern Interconnection system. Chapter Four presents the impacts of high PV on other electromechanical dynamic issues, including transient rotor angle stability and electromechanical wave propagation. Chapter Five investigates the frequency response enhancement by conventional resources. Chapter Six explores system frequency response improvement through real power control of wind and PV. For improving situation awareness and frequency control, Chapter Seven studies disturbance location determination based on electromechanical wave propagation. In addition, a new method is developed to generate the electromechanical wave propagation speed map, which is useful to detect system inertia distribution change. Chapter Eight provides a review on power grid data architectures for monitoring and controlling power grids. Challenges and essential elements of data architecture are analyzed to identify various requirements for operating high-renewable power grids and a conceptual data architecture is proposed. Conclusions of this dissertation study are given in Chapter Nine

    Synchrophasors: Multilevel Assessment and Data Quality Improvement for Enhanced System Reliability

    Get PDF
    . This study presents a comprehensive framework for testing and evaluation of Phasor Measurement Units (PMUs) and synchrophasor systems under normal power system operating conditions, as well as during disturbances such as faults and transients. The proposed framework suggests a performance assessment to be conducted in three steps: (a) type testing: conducted in the synchrophasor calibration laboratory according to accepted industrial standards; (b) application testing: conducted to evaluate the performance of the PMUs under faults, transients, and other disturbances in power systems; (c) end-to-end system testing: conducted to assess the risk and quantify the impact of measurement errors on the applications of interest. The suggested calibration toolset (type testing) enables performance characterization of different design alternatives in a standalone PMU (e.g., length of phasor estimation windows, filtering windows, reporting rates, etc.). In conjunction with the standard performance requirements, this work defines new metrics for PMU performance evaluations under any static and dynamic conditions that may unfold in the grid. The new metrics offer a more realistic understanding of the overall PMU performance and help users choose the appropriate device/settings for the target applications. Furthermore, the proposed probabilistic techniques quantify the PMU accuracy to various test performance thresholds specified by corresponding IEEE standards, rather than having only the pass/fail test outcome, as well as the probability of specific failures to meet the standard requirements defined in terms of the phasor, frequency, and rate of change of frequency accuracy. Application testing analysis encompasses PMU performance evaluation under faults and other prevailing conditions, and offers a realistic assessment of the PMU measurement errors in real-world field scenarios and reveals additional performance characteristics that are crucial for the overall application evaluation. End-to-end system tests quantify the impact of synchrophasor estimation errors and their propagation from the PMU towards the end-use applications and evaluate the associated risk. In this work, extensive experimental results demonstrate the advantages of the proposed framework and its applicability is verified through two synchrophasor applications, namely: Fault Location and Modal Analysis. Finally, a data-driven technique (Principal Component Pursuit) is proposed for the correction and completion of the synchrophasor data blocks, and its application and effectiveness is validated in modal analyzes

    Wide-Area Synchrophasor Data Server System and Data Analytics Platform

    Get PDF
    As synchrophasor data start to play a significant role in power system operation and dynamic study, data processing and data analysis capability are critical to Wide-area measurement systems (WAMS). The Frequency Monitoring Network (FNET/GridEye) is a WAMS network that collects data from hundreds of Frequency Disturbance Recorders (FDRs) at the distribution level. The previous FNET/GridEye data center is limited by its data storage capability and computation power. Targeting scalability, extensibility, concurrency and robustness, a distributed data analytics platform is proposed to process large volume, high velocity dataset. A variety of real-time and non-real-time synchrophasor data analytics applications are hosted by this platform. The computation load is shared with balance by multiple nodes of the analytics cluster, and big data analytics tools such as Apache Spark are adopted to manage large volume data and to boost the data processing speed. Multiple power system disturbance detection and analysis applications are redesigned to take advantage of this platform. Data quality and data security are monitored in real-time. Future data analytics applications can be easily developed and plugged into the system with simple configuration

    Performance Improvement of Wide-Area-Monitoring-System (WAMS) and Applications Development

    Get PDF
    Wide area monitoring system (WAMS), as an application of situation awareness, provides essential information for power system monitoring, planning, operation, and control. To fully utilize WAMS in smart grid, it is important to investigate and improve its performance, and develop advanced applications based on the data from WAMS. In this dissertation, the work on improving the WAMS performance and developing advanced applications are introduced.To improve the performance of WAMS, the work includes investigation of the impacts of measurement error and the requirements of system based on WAMS, and the solutions. PMU is one of the main sensors for WAMS. The phasor and frequency estimation algorithms implemented highly influence the performance of PMUs, and therefore the WAMS. The algorithms of PMUs are reviewed in Chapter 2. To understand how the errors impact WAMS application, different applications are investigated in Chapter 3, and their requirements of accuracy are given. In chapter 4, the error model of PMUs are developed, regarding different parameters of input signals and PMU operation conditions. The factors influence of accuracy of PMUs are analyzed in Chapter 5, including both internal and external error sources. Specifically, the impacts of increase renewables are analyzed. Based on the analysis above, a novel PMU is developed in Chapter 6, including algorithm and realization. This PMU is able to provide high accurate and fast responding measurements during both steady and dynamic state. It is potential to improve the performance of WAMS. To improve the interoperability, the C37.118.2 based data communication protocol is curtailed and realized for single-phase distribution-level PMUs, which are presented in Chapter 7.WAMS-based applications are developed and introduced in Chapter 8-10. The first application is to use the spatial and temporal characterization of power system frequency for data authentication, location estimation and the detection of cyber-attack. The second application is to detect the GPS attack on the synchronized time interval. The third application is to detect the geomagnetically induced currents (GIC) resulted from GMD and EMP-E3. These applications, benefited from the novel PMU proposed in Chapter 6, can be used to enhance the security and robust of power system

    Stability Analysis and Control of Nonlinear Power System Oscillations

    Get PDF
    This work investigates the nonlinear oscillatory behaviors of multi-machine power systems. New model-based and measurement-based approaches are proposed for stability analysis and control of nonlinear oscillations. For stability analysis, a recently proposed model-based nonlinear oscillation analysis method, nonlinear modal decoupling (NMD), is investigated on its ability in capturing the stability information of a multi-machine power system. From the differential-equation model of the power system, the NMD inversely constructs a set of 1-degree-of-freedom nonlinear oscillators, referred to as decoupled oscillators or subsystems, with each one corresponding to an oscillation mode of the original system. It is shown that retaining high order polynomial terms in the differential equation of each decoupled oscillator can make it more accurately represent the nonlinear modal dynamics and conditions of stability regarding the corresponding oscillation mode. For power system analysis, keeping the polynomial terms up to the 3rd-order during the decoupling is acceptable for the purpose of approximating assessment for transient stability. A transient stability analysis approach is proposed to apply the NMD for early warning of transient instability caused by inter-area oscillations. This new approach simplifies the real-time monitoring of the whole power system to the monitoring of only a few critical modes by checking the dynamics of the corresponding decoupled oscillators and their stability boundaries. Thus, when a critical oscillation mode is going to evolve into a mode of instability, this approach can provide early warning to the power system operator. For stability control, a direct damping feedback control method is proposed to control the damping ratio of a target dominant mode to closely follow a pre-set value by utilizing power converter-interfaced energy resources, e.g. battery-based energy storage devices. The direct damping feedback controller is designed to consist of a proportional-integral controller, a low-pass filter and a power system module that includes a reduced single-oscillator power system equivalent on the target oscillation mode and its measurement-based damping estimation algorithm. The parameters of the PI controller are optimized by considering the trade-off between the requirements of robustness and control performance. The power system module is represented by a transfer function based on the zeroth-order parametric resonance phenomenon. By identifying a nonlinear oscillator to fit dynamics of the target mode under both small and large disturbances, the measurement-based real-time damping estimation algorithm provides a feedback signal to the direct damping feedback controller. Numerical studies on the 48-machine Northeast Power Coordinating Council system validate the effectiveness of the proposed damping control method
    • …
    corecore