114 research outputs found

    Snake-Like Robots for Minimally Invasive, Single Port, and Intraluminal Surgeries

    Full text link
    The surgical paradigm of Minimally Invasive Surgery (MIS) has been a key driver to the adoption of robotic surgical assistance. Progress in the last three decades has led to a gradual transition from manual laparoscopic surgery with rigid instruments to robot-assisted surgery. In the last decade, the increasing demand for new surgical paradigms to enable access into the anatomy without skin incision (intraluminal surgery) or with a single skin incision (Single Port Access surgery - SPA) has led researchers to investigate snake-like flexible surgical devices. In this chapter, we first present an overview of the background, motivation, and taxonomy of MIS and its newer derivatives. Challenges of MIS and its newer derivatives (SPA and intraluminal surgery) are outlined along with the architectures of new snake-like robots meeting these challenges. We also examine the commercial and research surgical platforms developed over the years, to address the specific functional requirements and constraints imposed by operations in confined spaces. The chapter concludes with an evaluation of open problems in surgical robotics for intraluminal and SPA, and a look at future trends in surgical robot design that could potentially address these unmet needs.Comment: 41 pages, 18 figures. Preprint of article published in the Encyclopedia of Medical Robotics 2018, World Scientific Publishing Company www.worldscientific.com/doi/abs/10.1142/9789813232266_000

    Platforms for prototyping minimally invasive instruments

    Get PDF
    The introduction of new technologies in medicine is often an issue because there are many stages to go through, from the idea to the approval by ethical committees and mass production. This work covers the first steps of the development of a medical device, dealing with the tools that can help to reduce the time for producing the laboratory prototype. These tools can involve electronics and software for the creation of a “universal”' hardware platform that can be used for many robotic applications, adapting only few components for the specific scenario. The platform is created by setting up a traditional computer with operating system and acquisition channels aimed at opening the system toward the real environment. On this platform algorithms can be implemented rapidly, allowing to assess the feasibility of an idea. This approach lets the designer concentrate on the application rather than on the selection of the appropriate hardware electronics every time that a new project starts. In the first part an overview of the existing instruments for minimally invasive interventions that can be found as commercial or research products is given. An introduction related to hardware electronics is presented with the requirements and the specific characteristics needed for a robotic application. The second part focuses on specific projects in MIS. The first project concerns the study and the development of a lightweight hand-held robotic instrument for laparoscopy. Motivations are related to the lack of dexterous hand-held laparoscopic instruments. The second project concerns the study and the presentation of a prototype of a robotic endoscope with enhanced resolution. The third project concerns the development of a system able to detect the inspiration and the expiration phases. The aim is to evaluate the weariness of the surgeon, since breathing can be related to fatigue

    Visual SLAM for Measurement and Augmented Reality in Laparoscopic Surgery

    Get PDF
    In spite of the great advances in laparoscopic surgery, this type of surgery still shows some difficulties during its realization, mainly caused by its complex maneuvers and, above all, by the loss of the depth perception. Unlike classical open surgery --laparotomy-- where surgeons have direct contact with organs and a complete 3D perception, laparoscopy is carried out by means of specialized instruments, and a monocular camera (laparoscope) in which the 3D scene is projected into a 2D plane --image. The main goal of this thesis is to face with this loss of depth perception by making use of Simultaneous Localization and Mapping (SLAM) algorithms developed in the fields of robotics and computer vision during the last years. These algorithms allow to localize, in real time (25 \thicksim 30 frames per second), a camera that moves freely inside an unknown rigid environment while, at the same time, they build a map of this environment by exploiting images gathered by that camera. These algorithms have been extensively validated both in man-made environments (buildings, rooms, ...) and in outdoor environments, showing robustness to occlusions, sudden camera motions, or clutter. This thesis tries to extend the use of these algorithms to laparoscopic surgery. Due to the intrinsic nature of internal body images (they suffer from deformations, specularities, variable illumination conditions, limited movements, ...), applying this type of algorithms to laparoscopy supposes a real challenge. Knowing the camera (laparoscope) location with respect to the scene (abdominal cavity) and the 3D map of that scene opens new interesting possibilities inside the surgical field. This knowledge enables to do augmented reality annotations directly on the laparoscopic images (e.g. alignment of preoperative 3D CT models); intracavity 3D distance measurements; or photorealistic 3D reconstructions of the abdominal cavity recovering synthetically the lost depth. These new facilities provide security and rapidity to surgical procedures without disturbing the classical procedure workflow. Hence, these tools are available inside the surgeon's armory, being the surgeon who decides to use them or not. Additionally, knowledge of the camera location with respect to the patient's abdominal cavity is fundamental for future development of robots that can operate automatically since, knowing this location, the robot will be able to localize other tools controlled by itself with respect to the patient. In detail, the contributions of this thesis are: - To demonstrate the feasibility of applying SLAM algorithms to laparoscopy showing experimentally that using robust data association is a must. - To robustify one of these algorithms, in particular the monocular EKF-SLAM algorithm, by adapting a relocalization system and improving data association with a robust matching algorithm. - To develop of a robust matching method (1-Point RANSAC algorithm). - To develop a new surgical procedure to ease the use of visual SLAM in laparoscopy. - To make an extensive validation of the robust EKF-SLAM (EKF + relocalization + 1-Point RANSAC) obtaining millimetric errors and working in real time both on simulation and real human surgeries. The selected surgery has been the ventral hernia repair. - To demonstrate the potential of these algorithms in laparoscopy: they recover synthetically the depth of the operative field which is lost by using monocular laparoscopes, enable the insertion of augmented reality annotations, and allow to perform distance measurements using only a laparoscopic tool (to define the real scale) and laparoscopic images. - To make a clinical validation showing that these algorithms allow to shorten surgical times of operations and provide more security to the surgical procedures

    A spherical joint robotic end-effector for the Expanded Endoscopic Endonasal Approach

    Get PDF
    The endonasal transsphenoidal approach allows surgeons to access the pituitary gland through the natural orifice of the nose. Recently, surgeons have also described an Expanded Endoscopic Endonasal Approach (EEEA) for the treatment of other tumours around the base of the brain. However, operating in this way with nonarticulated tools is technically very difficult and not widely adopted. The goal of this study is to develop an articulated end-effector for a novel handheld robotic tool for the EEEA. We present a design and implementation of a 3.6mm diameter, three degrees-of-freedom, tendon-driven robotic end-effector that, contrary to rigid instruments which operate under fulcrum, will give the surgeon the ability to reach areas on the surface of the brain that were previously inaccessible. We model the end-effector kinematics in simulation to study the theoretical workspace it can achieve prior to implementing a test-bench device to validate the efficacy of the end-effector. We find promising repeatability of the proposed robotic end-effector of 0.42mm with an effective workspace with limits of ±30∘, which is greater than conventional neurosurgical tools. Additionally, although the tool’s end-effector has a small enough diameter to operate through the narrow nasal access path and the constrained workspace of EEEA, it showcased promising structural integrity and was able to support approximately a 6N load, despite a large deflection angle the limiting of which is scope of future work. These preliminary results indicate the end-effector is a promising first step towards developing appropriate handheld robotic instrumentation to drive EEEA adoption

    Design, Modeling and Control of Micro-scale and Meso-scale Tendon-Driven Surgical Robots

    Get PDF
    Manual manipulation of passive surgical tools is time consuming with uncertain results in cases of navigating tortuous anatomy, avoiding critical anatomical landmarks, and reaching targets not located in the linear range of these tools. For example, in many cardiovascular procedures, manual navigation of a micro-scale passive guidewire results in increased procedure times and radiation exposure. This thesis introduces the design of two steerable guidewires: 1) A two degree-of-freedom (2-DoF) robotic guidewire with orthogonally oriented joints to access points in a three dimensional workspace, and 2) a micro-scale coaxially aligned steerable (COAST) guidewire robot that demonstrates variable and independently controlled bending length and curvature of the distal end. The 2-DoF guidewire features two micromachined joints from a tube of superelastic nitinol of outer diameter 0.78 mm. Each joint is actuated with two nitinol tendons. The joints that are used in this robot are called bidirectional asymmetric notch (BAN) joints, and the advantages of these joints are explored and analyzed. The design of the COAST robotic guidewire involves three coaxially aligned tubes with a single tendon running centrally through the length of the robot. The outer tubes are made from micromachined nitinol allowing for tendon-driven bending of the robot at variable bending curvatures, while an inner stainless steel tube controls the bending length of the robot. By varying the lengths of the tubes as well as the tendon, and by insertion and retraction of the entire assembly, various joint lengths and curvatures may be achieved. Kinematic and static models, a compact actuation system, and a controller for this robot are presented. The capability of the robot to accurately navigate through phantom anatomical bifurcations and tortuous angles is also demonstrated in three dimensional phantom vasculature. At the meso-scale, manual navigation of passive pediatric neuroendoscopes for endoscopic third ventriculostomy may not reach target locations in the patient's ventricle. This work introduces the design, analysis and control of a meso-scale two degree-of-freedom robotic bipolar electrocautery tool that increases the workspace of the neurosurgeon. A static model is proposed for the robot joints that avoids problems arising from pure kinematic control. Using this model, a control system is developed that comprises of a disturbance observer to provide precise force control and compensate for joint hysteresis. A handheld controller is developed and demonstrated in this thesis. To allow the clinician to estimate the shape of the steerable tools within the anatomy for both micro-scale and meso-scale tools, a miniature tendon force sensor and a high deflection shape sensor are proposed and demonstrated. The force sensor features a compact design consisting of a single LED, dual-phototransistor, and a dual-screen arrangement to increase the linear range of sensor output and compensate for external disturbances, thereby allowing force measurement of up to 21 N with 99.58 % accuracy. The shape sensor uses fiber Bragg grating based optical cable mounted on a micromachined tube and is capable of measuring curvatures as high as 145 /m. These sensors were incorporated and tested in the guidewire and the neuroendoscope tool robots and can provide robust feedback for closed-loop control of these devices in the future.Ph.D

    Modeling, Analysis, Force Sensing and Control of Continuum Robots for Minimally Invasive Surgery

    Get PDF
    This dissertation describes design, modeling and application of continuum robotics for surgical applications, specifically parallel continuum robots (PCRs) and concentric tube manipulators (CTMs). The introduction of robotics into surgical applications has allowed for a greater degree of precision, less invasive access to more remote surgical sites, and user-intuitive interfaces with enhanced vision systems. The most recent developments have been in the space of continuum robots, whose exible structure create an inherent safety factor when in contact with fragile tissues. The design challenges that exist involve balancing size and strength of the manipulators, controlling the manipulators over long transmission pathways, and incorporating force sensing and feedback from the manipulators to the user. Contributions presented in this work include: (1) prototyping, design, force sensing, and force control investigations of PCRs, and (2) prototyping of a concentric tube manipulator for use in a standard colonoscope. A general kinetostatic model is presented for PCRs along with identification of multiple physical constraints encountered in design and construction. Design considerations and manipulator capabilities are examined in the form of matrix metrics and ellipsoid representations. Finally, force sensing and control are explored and experimental results are provided showing the accuracy of force estimates based on actuation force measurements and control capabilities. An overview of the design requirements, manipulator construction, analysis and experimental results are provided for a CTM used as a tool manipulator in a traditional colonoscope. Currently, tools used in colonoscopic procedures are straight and exit the front of the scope with 1 DOF of operation (jaws of a grasper, tightening of a loop, etc.). This research shows that with a CTM deployed, the dexterity of these tools can be increased dramatically, increasing accuracy of tool operation, ease of use and safety of the overall procedure. The prototype investigated in this work allows for multiple tools to be used during a single procedure. Experimental results show the feasibility and advantages of the newly-designed manipulators

    Characterisation and State Estimation of Magnetic Soft Continuum Robots

    Get PDF
    Minimally invasive surgery has become more popular as it leads to less bleeding, scarring, pain, and shorter recovery time. However, this has come with counter-intuitive devices and steep surgeon learning curves. Magnetically actuated Soft Continuum Robots (SCR) have the potential to replace these devices, providing high dexterity together with the ability to conform to complex environments and safe human interactions without the cognitive burden for the clinician. Despite considerable progress in the past decade in their development, several challenges still plague SCR hindering their full realisation. This thesis aims at improving magnetically actuated SCR by addressing some of these challenges, such as material characterisation and modelling, and sensing feedback and localisation. Material characterisation for SCR is essential for understanding their behaviour and designing effective modelling and simulation strategies. In this work, the material properties of commonly employed materials in magnetically actuated SCR, such as elastic modulus, hyper-elastic model parameters, and magnetic moment were determined. Additionally, the effect these parameters have on modelling and simulating these devices was investigated. Due to the nature of magnetic actuation, localisation is of utmost importance to ensure accurate control and delivery of functionality. As such, two localisation strategies for magnetically actuated SCR were developed, one capable of estimating the full 6 degrees of freedom (DOFs) pose without any prior pose information, and another capable of accurately tracking the full 6-DOFs in real-time with positional errors lower than 4~mm. These will contribute to the development of autonomous navigation and closed-loop control of magnetically actuated SCR

    A flexible access platform for robot-assisted minimally invasive surgery

    No full text
    Advances in Minimally Invasive Surgery (MIS) are driven by the clinical demand to reduce the invasiveness of surgical procedures so patients undergo less trauma and experience faster recoveries. These well documented benefits of MIS have been achieved through parallel advances in the technology and instrumentation used during procedures. The new and evolving field of Flexible Access Surgery (FAS), where surgeons access the operative site through a single incision or a natural orifice incision, is being promoted as the next potential step in the evolution of surgery. In order to achieve similar levels of success and adoption as MIS, technology again has its role to play in developing new instruments to solve the unmet clinical challenges of FAS. As procedures become less invasive, these instruments should not just address the challenges presented by the complex access routes of FAS, but should also build on the recent advances in pre- and intraoperative imaging techniques to provide surgeons with new diagnostic and interventional decision making capabilities. The main focus of this thesis is the development and applications of a flexible robotic device that is capable of providing controlled flexibility along curved pathways inside the body. The principal component of the device is its modular mechatronic joint design which utilises an embedded micromotor-tendon actuation scheme to provide independently addressable degrees of freedom and three internal working channels. Connecting multiple modules together allows a seven degree-of-freedom (DoF) flexible access platform to be constructed. The platform is intended for use as a research test-bed to explore engineering and surgical challenges of FAS. Navigation of the platform is realised using a handheld controller optimised for functionality and ergonomics, or in a "hands-free" manner via a gaze contingent control framework. Under this framework, the operator's gaze fixation point is used as feedback to close the servo control loop. The feasibility and potential of integrating multi-spectral imaging capabilities into flexible robotic devices is also demonstrated. A force adaptive servoing mechanism is developed to simplify the deployment, and improve the consistency of probe-based optical imaging techniques by automatically controlling the contact force between the probe tip and target tissue. The thesis concludes with the description of two FAS case studies performed with the platform during in-vivo porcine experiments. These studies demonstrate the ability of the platform to perform large area explorations within the peritoneal cavity and to provide a stable base for the deployment of interventional instruments and imaging probes

    Endoscopic and magnetic actuation for miniature lifesaving devices

    Get PDF

    Towards tactile sensing active capsule endoscopy

    Get PDF
    Examination of the gastrointestinal(GI) tract has traditionally been performed using tethered endoscopy tools with limited reach and more recently with passive untethered capsule endoscopy with limited capability. Inspection of small intestines is only possible using the latter capsule endoscopy with on board camera system. Limited to visual means it cannot detect features beneath the lumen wall if they have not affected the lumen structure or colour. This work presents an improved capsule endoscopy system with locomotion for active exploration of the small intestines and tactile sensing to detect deformation of the capsule outer surface when it follows the intestinal wall. In laboratory conditions this system is capable of identifying sub-lumen features such as submucosal tumours.Through an extensive literary review the current state of GI tract inspection in particular using remote operated miniature robotics, was investigated, concluding no solution currently exists that utilises tactile sensing with a capsule endoscopy. In order to achieve such a platform, further investigation was made in to tactile sensing technologies, methods of locomotion through the gut, and methods to support an increased power requirement for additional electronics and actuation. A set of detailed criteria were compiled for a soft formed sensor and flexible bodied locomotion system. The sensing system is built on the biomimetic tactile sensing device, Tactip, \cite{Chorley2008, Chorley2010, Winstone2012, Winstone2013} which has been redesigned to fit the form of a capsule endoscopy. These modifications have required a 360o360^{o} cylindrical sensing surface with 360o360^{o} panoramic optical system. Multi-material 3D printing has been used to build an almost complete sensor assembly with a combination of hard and soft materials, presenting a soft compliant tactile sensing system that mimics the tactile sensing methods of the human finger. The cylindrical Tactip has been validated using artificial submucosal tumours in laboratory conditions. The first experiment has explored the new form factor and measured the device's ability to detect surface deformation when travelling through a pipe like structure with varying lump obstructions. Sensor data was analysed and used to reconstruct the test environment as a 3D rendered structure. A second tactile sensing experiment has explored the use of classifier algorithms to successfully discriminate between three tumour characteristics; shape, size and material hardness. Locomotion of the capsule endoscopy has explored further bio-inspiration from earthworm's peristaltic locomotion, which share operating environment similarities. A soft bodied peristaltic worm robot has been developed that uses a tuned planetary gearbox mechanism to displace tendons that contract each worm segment. Methods have been identified to optimise the gearbox parameter to a pipe like structure of a given diameter. The locomotion system has been tested within a laboratory constructed pipe environment, showing that using only one actuator, three independent worm segments can be controlled. This configuration achieves comparable locomotion capabilities to that of an identical robot with an actuator dedicated to each individual worm segment. This system can be miniaturised more easily due to reduced parts and number of actuators, and so is more suitable for capsule endoscopy. Finally, these two developments have been integrated to demonstrate successful simultaneous locomotion and sensing to detect an artificial submucosal tumour embedded within the test environment. The addition of both tactile sensing and locomotion have created a need for additional power beyond what is available from current battery technology. Early stage work has reviewed wireless power transfer (WPT) as a potential solution to this problem. Methods for optimisation and miniaturisation to implement WPT on a capsule endoscopy have been identified with a laboratory built system that validates the methods found. Future work would see this combined with a miniaturised development of the robot presented. This thesis has developed a novel method for sub-lumen examination. With further efforts to miniaturise the robot it could provide a comfortable and non-invasive procedure to GI tract inspection reducing the need for surgical procedures and accessibility for earlier stage of examination. Furthermore, these developments have applicability in other domains such as veterinary medicine, industrial pipe inspection and exploration of hazardous environments
    corecore