    Development, Optimization and Clinical Evaluation Of Algorithms For Ultrasound Data Analysis Used In Selected Medical Applications.

    Get PDF
    The assessment of soft and hard tissues is critical when selecting appropriate protocols for restorative and regenerative therapy in the field of dental surgery. The chosen treatment methodology will have significant ramifications on healing time, success rate and overall long-time oral health. Currently used diagnostic methods are limited to visual and invasive assessments; they are often user-dependent, inaccurate and result in misinterpretation. As such, the clinical need has been identified for objective tissue characterization, and the proposed novel ultrasound-based approach was designed to address the identified need. The device prototype consists of a miniaturized probe with a specifically designed ultrasonic transducer, electronics responsible for signal generation and acquisition, as well as an optimized signal processing algorithm required for data analysis. An algorithm where signals are being processed and features extracted in real-time has been implemented and studied. An in-depth algorithm performance study has been presented on synthetic signals. Further, in-vitro laboratory experiments were performed using the developed device with the algorithm implemented in software on animal-based samples. Results validated the capabilities of the new system to reproduce gingival assessment rapidly and effectively. The developed device has met clinical usability requirements for effectiveness and performance

    FPGA-Based Portable Ultrasound Scanning System with Automatic Kidney Detection

    Get PDF
    Bedsides diagnosis using portable ultrasound scanning (PUS) offering comfortable diagnosis with various clinical advantages, in general, ultrasound scanners suffer from a poor signal-to-noise ratio, and physicians who operate the device at point-of-care may not be adequately trained to perform high level diagnosis. Such scenarios can be eradicated by incorporating ambient intelligence in PUS. In this paper, we propose an architecture for a PUS system, whose abilities include automated kidney detection in real time. Automated kidney detection is performed by training the Viola–Jones algorithm with a good set of kidney data consisting of diversified shapes and sizes. It is observed that the kidney detection algorithm delivers very good performance in terms of detection accuracy. The proposed PUS with kidney detection algorithm is implemented on a single Xilinx Kintex-7 FPGA, integrated with a Raspberry Pi ARM processor running at 900 MHz

    Portable Ultrasound Imaging

    Get PDF
    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs of the ultrasound system and, consequently, to allow for a wide-scale utilization of diagnostic ultrasound in any medical specialties and out of the radiology department. The first part of the contribution deals with the study of hardware solutions for the reduction of the system complexity. Analog and digital beamforming strategies are simulated from a system-level perspective. The quality of the B-mode image is evaluated and the minimum specifications are derived for the design of a portable probe with integrated electronics in-handle. The system is based on a synthetic aperture sequential beamforming approach that allows to significantly reduce the data rate between the probe and processing unit. The second part investigates the feasibility of vector flow imaging in a hand-held ultrasound system. Vector flow imaging overcomes the limitations of conventional imaging methods in terms of flow angle compensation. Furthermore, high frame rate can be obtained by using synthetic aperture focusing techniques. A method is developed combining synthetic aperture sequential beamforming and directional transverse oscillation to achieve the wireless transmission of the data along with a relatively inexpensive 2-D velocity estimation. The performance of the method is thoroughly assessed through simulations and measurements, and in vivo investigations are carried out to show its potential in presence of complex flow dynamics. A sufficient frame rate is achieved to allow for the visualization of vortices in the carotid bifurcation. Furthermore, the method is implemented on a commercially available tablet to evaluate the real-time processing performance in the built-in GPU with concurrent wireless transmission of the data. Based on the demonstrations in this thesis, a flexible framework can be implemented with performance that can be scaled to the needs of the user and according to the computing resources available. The integration of high-frame-rate vector flow imaging in a hand-held ultrasound scanner, in addition, has the potential to improve the operator’s workflow and opens the way to new possibilities in the clinical practice

    An Inertial-Optical Tracking System for Quantitative, Freehand, 3D Ultrasound

    Get PDF
    Three dimensional (3D) ultrasound has become an increasingly popular medical imaging tool over the last decade. It offers significant advantages over Two Dimensional (2D) ultrasound, such as improved accuracy, the ability to display image planes that are physically impossible with 2D ultrasound, and reduced dependence on the skill of the sonographer. Among 3D medical imaging techniques, ultrasound is the only one portable enough to be used by first responders, on the battlefield, and in rural areas. There are three basic methods of acquiring 3D ultrasound images. In the first method, a 2D array transducer is used to capture a 3D volume directly, using electronic beam steering. This method is mainly used for echocardiography. In the second method, a linear array transducer is mechanically actuated, giving a slower and less expensive alternative to the 2D array. The third method uses a linear array transducer that is moved by hand. This method is known as freehand 3D ultrasound. Whether using a 2D array or a mechanically actuated linear array transducer, the position and orientation of each image is known ahead of time. This is not the case for freehand scanning. To reconstruct a 3D volume from a series of 2D ultrasound images, assumptions must be made about the position and orientation of each image, or a mechanism for detecting the position and orientation of each image must be employed. The most widely used method for freehand 3D imaging relies on the assumption that the probe moves along a straight path with constant orientation and speed. This method requires considerable skill on the part of the sonographer. Another technique uses features within the images themselves to form an estimate of each image\u27s relative location. However, these techniques are not well accepted for diagnostic use because they are not always reliable. The final method for acquiring position and orientation information is to use a six Degree-of-Freedom (6 DoF) tracking system. Commercially available 6 DoF tracking systems use magnetic fields, ultrasonic ranging, or optical tracking to measure the position and orientation of a target. Although accurate, all of these systems have fundamental limitations in that they are relatively expensive and they all require sensors or transmitters to be placed in fixed locations to provide a fixed frame of reference. The goal of the work presented here is to create a probe tracking system for freehand 3D ultrasound that does not rely on any fixed frame of reference. This system tracks the ultrasound probe using only sensors integrated into the probe itself. The advantages of such a system are that it requires no setup before it can be used, it is more portable because no extra equipment is required, it is immune from environmental interference, and it is less expensive than external tracking systems. An ideal tracking system for freehand 3D ultrasound would track in all 6 DoF. However, current sensor technology limits this system to five. Linear transducer motion along the skin surface is tracked optically and transducer orientation is tracked using MEMS gyroscopes. An optical tracking system was developed around an optical mouse sensor to provide linear position information by tracking the skin surface. Two versions were evaluated. One included an optical fiber bundle and the other did not. The purpose of the optical fiber is to allow the system to integrate more easily into existing probes by allowing the sensor and electronics to be mounted away from the scanning end of the probe. Each version was optimized to track features on the skin surface while providing adequate Depth Of Field (DOF) to accept variation in the height of the skin surface. Orientation information is acquired using a 3 axis MEMS gyroscope. The sensor was thoroughly characterized to quantify performance in terms of accuracy and drift. This data provided a basis for estimating the achievable 3D reconstruction accuracy of the complete system. Electrical and mechanical components were designed to attach the sensor to the ultrasound probe in such a way as to simulate its being embedded in the probe itself. An embedded system was developed to perform the processing necessary to translate the sensor data into probe position and orientation estimates in real time. The system utilizes a Microblaze soft core microprocessor and a set of peripheral devices implemented in a Xilinx Spartan 3E field programmable gate array. The Xilinx Microkernel real time operating system performs essential system management tasks and provides a stable software platform for implementation of the inertial tracking algorithm. Stradwin 3D ultrasound software was used to provide a user interface and perform the actual 3D volume reconstruction. Stradwin retrieves 2D ultrasound images from the Terason t3000 portable ultrasound system and communicates with the tracking system to gather position and orientation data. The 3D reconstruction is generated and displayed on the screen of the PC in real time. Stradwin also provides essential system features such as storage and retrieval of data, 3D data interaction, reslicing, manual 3D segmentation, and volume calculation for segmented regions. The 3D reconstruction performance of the system was evaluated by freehand scanning a cylindrical inclusion in a CIRS model 044 ultrasound phantom. Five different motion profiles were used and each profile was repeated 10 times. This entire test regimen was performed twice, once with the optical tracking system using the optical fiber bundle, and once with the optical tracking system without the optical fiber bundle. 3D reconstructions were performed with and without the position and orientation data to provide a basis for comparison. Volume error and surface error were used as the performance metrics. Volume error ranged from 1.3% to 5.3% with tracking information versus 15.6% to 21.9% without for the version of the system without the optical fiber bundle. Volume error ranged from 3.7% to 7.6% with tracking information versus 8.7% to 13.7% without for the version of the system with the optical fiber bundle. Surface error ranged from 0.319 mm RMS to 0.462 mm RMS with tracking information versus 0.678 mm RMS to 1.261 mm RMS without for the version of the system without the optical fiber bundle. Surface error ranged from 0.326 mm RMS to 0.774 mm RMS with tracking information versus 0.538 mm RMS to 1.657 mm RMS without for the version of the system with the optical fiber bundle. The prototype tracking system successfully demonstrated that accurate 3D ultrasound volumes can be generated from 2D freehand data using only sensors integrated into the ultrasound probe. One serious shortcoming of this system is that it only tracks 5 of the 6 degrees of freedom required to perform complete 3D reconstructions. The optical system provides information about linear movement but because it tracks a surface, it cannot measure vertical displacement. Overcoming this limitation is the most obvious candidate for future research using this system. The overall tracking platform, meaning the embedded tracking computer and the PC software, developed and integrated in this work, is ready to take advantage of vertical displacement data, should a method be developed for sensing it

    Miniature mobile sensor platforms for condition monitoring of structures

    Get PDF
    In this paper, a wireless, multisensor inspection system for nondestructive evaluation (NDE) of materials is described. The sensor configuration enables two inspection modes-magnetic (flux leakage and eddy current) and noncontact ultrasound. Each is designed to function in a complementary manner, maximizing the potential for detection of both surface and internal defects. Particular emphasis is placed on the generic architecture of a novel, intelligent sensor platform, and its positioning on the structure under test. The sensor units are capable of wireless communication with a remote host computer, which controls manipulation and data interpretation. Results are presented in the form of automatic scans with different NDE sensors in a series of experiments on thin plate structures. To highlight the advantage of utilizing multiple inspection modalities, data fusion approaches are employed to combine data collected by complementary sensor systems. Fusion of data is shown to demonstrate the potential for improved inspection reliability

    Micromachined Scanning Devices for 3D Acoustic Imaging

    Get PDF
    Acoustic imaging (including ultrasound and photoacoustic imaging) refers to a class of imaging methods that use high-frequency sound (ultrasound) waves to generate contrast images for the interrogated media. It provides 3D spatial distribution of structural, mechanical, and even compositional properties in different materials. To conduct 3D ultrasound imaging, 2D ultrasound transducer arrays followed by multi-channel high-frequency data acquisition (DAQ) systems are frequently used. However, as the quantity and density of the transducer elements and also the DAQ channels increase, the acoustic imaging system becomes complex, bulky, expensive, and also power consuming. This situation is especially true for 3D imaging systems, where a 2D transducer array with hundreds or even thousands of elements could be involved. To address this issue, the objective of this research is to achieve new micromachined scanning devices to enable fast and versatile 2D ultrasound signal acquisition for 3D image reconstruction without involving complex physical transducer arrays and DAQ electronics. The new micromachined scanning devices studied in this research include 1) a water-immersible scanning mirror microsystem, 2) a micromechanical scanning transducer, and 3) a multi-layer linear transducer array. Especially, the water-immersible scanning mirror microsystem is capable of scanning focused ultrasound beam (from a single-element transducer) in two dimensions for 3D high-resolution acoustic microscopy. The micromechanical scanning transducer is capable of sending and receiving ultrasound signal from a single-element transducer to a 2D array of locations for 3D acoustic tomography. The multi-layer linear transducer array allows a unique electronic scanning scheme to simulate the functioning of a much larger 2D transducer array for 3D acoustic tomography. The design, fabrication and testing of the above three devices have been successfully accomplished and their applications in 3D acoustic microscopy and tomography have been demonstrated

    Micromachined Scanning Devices for 3D Acoustic Imaging

    Get PDF
    Acoustic imaging (including ultrasound and photoacoustic imaging) refers to a class of imaging methods that use high-frequency sound (ultrasound) waves to generate contrast images for the interrogated media. It provides 3D spatial distribution of structural, mechanical, and even compositional properties in different materials. To conduct 3D ultrasound imaging, 2D ultrasound transducer arrays followed by multi-channel high-frequency data acquisition (DAQ) systems are frequently used. However, as the quantity and density of the transducer elements and also the DAQ channels increase, the acoustic imaging system becomes complex, bulky, expensive, and also power consuming. This situation is especially true for 3D imaging systems, where a 2D transducer array with hundreds or even thousands of elements could be involved. To address this issue, the objective of this research is to achieve new micromachined scanning devices to enable fast and versatile 2D ultrasound signal acquisition for 3D image reconstruction without involving complex physical transducer arrays and DAQ electronics. The new micromachined scanning devices studied in this research include 1) a water-immersible scanning mirror microsystem, 2) a micromechanical scanning transducer, and 3) a multi-layer linear transducer array. Especially, the water-immersible scanning mirror microsystem is capable of scanning focused ultrasound beam (from a single-element transducer) in two dimensions for 3D high-resolution acoustic microscopy. The micromechanical scanning transducer is capable of sending and receiving ultrasound signal from a single-element transducer to a 2D array of locations for 3D acoustic tomography. The multi-layer linear transducer array allows a unique electronic scanning scheme to simulate the functioning of a much larger 2D transducer array for 3D acoustic tomography. The design, fabrication and testing of the above three devices have been successfully accomplished and their applications in 3D acoustic microscopy and tomography have been demonstrated

    Portable Ultrasound Data Acquisition System Design

    Get PDF
    Ultrasound is radiation-free, patient-friendly and less expensive when compared to other medical imaging techniques. Ultrasound scanning has the capability to image the organs in real time, thus offering quick diagnosis. Conventional medical ultrasound machines are not suited for remote health monitoring because of their large form factor and lack of trained sonographers limiting its use only to urban areas and well trained clinicians. This thesis discusses the implementation of portable ultrasound data acquisition system for Point of Care (POC) applications in both of the system-level Hardware and Firmware design level. In the Hardware design, we are targeting the compact able application as well as the extendable applications where the power, level of integration and the feasible of the replication are critical. The portable system architecture for 8-channel consists of ASICs for ultrasound and FPGA. Beam forming is the front end process to steer and focus the acoustic beam with in the region of interest for diagnosis