7,824 research outputs found

    Compensation of Magnetic Disturbances Improves Inertial and Magnetic Sensing of Human Body Segment Orientation

    Get PDF
    This paper describes a complementary Kalman filter design to estimate orientation of human body segments by fusing gyroscope, accelerometer, and magnetometer signals from miniature sensors. Ferromagnetic materials or other magnetic fields near the sensor module disturb the local earth magnetic field and, therefore, the orientation estimation, which impedes many (ambulatory) applications. In the filter, the gyroscope bias error, orientation error, and magnetic disturbance error are estimated. The filter was tested under quasi-static and dynamic conditions with ferromagnetic materials close to the sensor module. The quasi-static experiments implied static positions and rotations around the three axes. In the dynamic experiments, three-dimensional rotations were performed near a metal tool case. The orientation estimated by the filter was compared with the orientation obtained with an optical reference system Vicon. Results show accurate and drift-free orientation estimates. The compensation results in a significant difference (p<0.01) between the orientation estimates with compensation of magnetic disturbances in comparison to no compensation or only gyroscopes. The average static error was 1.4/spl deg/ (standard deviation 0.4) in the magnetically disturbed experiments. The dynamic error was 2.6/spl deg/ root means square

    Inclination Measurement of Human Movement Using a 3-D Accelerometer With Autocalibration

    Get PDF
    In the medical field, accelerometers are often used for measuring inclination of body segments and activity of daily living (ADL) because they are small and require little power. A drawback of using accelerometers is the poor quality of inclination estimate for movements with large accelerations. This paper describes the design and performance of a Kalman filter to estimate inclination from the signals of a triaxial accelerometer. This design is based on assumptions concerning the frequency content of the acceleration of the movement that is measured, the knowledge that the magnitude of the gravity is 1 g and taking into account a fluctuating sensor offset. It is shown that for measuring trunk and pelvis inclination during the functional three-dimensional activity of stacking crates, the inclination error that is made is approximately 2/spl deg/ root-mean square. This is nearly twice as accurate as compared to current methods based on low-pass filtering of accelerometer signals

    Application of inertial instruments for DSN antenna pointing and tracking

    Get PDF
    The feasibility of using inertial instruments to determine the pointing attitude of the NASA Deep Space Network antennas is examined. The objective is to obtain 1 mdeg pointing knowledge in both blind pointing and tracking modes to facilitate operation of the Deep Space Network 70 m antennas at 32 GHz. A measurement system employing accelerometers, an inclinometer, and optical gyroscopes is proposed. The initial pointing attitude is established by determining the direction of the local gravity vector using the accelerometers and the inclinometer, and the Earth's spin axis using the gyroscopes. Pointing during long-term tracking is maintained by integrating the gyroscope rates and augmenting these measurements with knowledge of the local gravity vector. A minimum-variance estimator is used to combine measurements to obtain the antenna pointing attitude. A key feature of the algorithm is its ability to recalibrate accelerometer parameters during operation. A survey of available inertial instrument technologies is also given

    Inertial sensor-based knee flexion/extension angle estimation

    Get PDF
    A new method for estimating knee joint flexion/extension angles from segment acceleration and angular velocity data is described. The approach uses a combination of Kalman filters and biomechanical constraints based on anatomical knowledge. In contrast to many recently published methods, the proposed approach does not make use of the earth’s magnetic field and hence is insensitive to the complex field distortions commonly found in modern buildings. The method was validated experimentally by calculating knee angle from measurements taken from two IMUs placed on adjacent body segments. In contrast to many previous studies which have validated their approach during relatively slow activities or over short durations, the performance of the algorithm was evaluated during both walking and running over 5 minute periods. Seven healthy subjects were tested at various speeds from 1 to 5 miles/hour. Errors were estimated by comparing the results against data obtained simultaneously from a 10 camera motion tracking system (Qualysis). The average measurement error ranged from 0.7 degrees for slow walking (1 mph) to 3.4 degrees for running (5mph). The joint constraint used in the IMU analysis was derived from the Qualysis data. Limitations of the method, its clinical application and its possible extension are discussed

    The 2nd Generation VLTI path to performance

    Full text link
    The upgrade of the VLTI infrastructure for the 2nd generation instruments is now complete with the transformation of the laboratory, and installation of star separators on both the 1.8-m Auxiliary Telescopes (ATs) and the 8-m Unit Telescopes (UTs). The Gravity fringe tracker has had a full semester of commissioning on the ATs, and a first look at the UTs. The CIAO infrared wavefront sensor is about to demonstrate its performance relative to the visible wavefront sensor MACAO. First astrometric measurements on the ATs and astrometric qualification of the UTs are on-going. Now is a good time to revisit the performance roadmap for VLTI that was initiated in 2014, which aimed at coherently driving the developments of the interferometer, and especially its performance, in support to the new generation of instruments: Gravity and MATISSE.Comment: 9 pages, 6 figures, 1 table, Proc. SPIE 201

    Multi-Level Sensory Interpretation and Adaptation in a Mobile Cube

    Get PDF
    Signals from sensors are often analyzed in a sequence of steps, starting with the raw sensor data and eventually ending up with a classification or abstraction of these data. This paper will give a practical example of how the same information can be trained and used to initiate multiple interpretations of the same data on different, application-oriented levels. Crucially, the focus is on expanding embedded analysis software, rather than adding more powerful, but possibly resource-hungry, sensors. Our illustration of this approach involves a tangible input device the shape of a cube that relies exclusively on lowcost accelerometers. The cube supports calibration with user supervision, it can tell which of its sides is on top, give an estimate of its orientation relative to the user, and recognize basic gestures

    Tibial acceleration-based prediction of maximal vertical loading rate during overground running : a machine learning approach

    Get PDF
    Ground reaction forces are often used by sport scientists and clinicians to analyze the mechanical risk-factors of running related injuries or athletic performance during a running analysis. An interesting ground reaction force-derived variable to track is the maximal vertical instantaneous loading rate (VILR). This impact characteristic is traditionally derived from a fixed force platform, but wearable inertial sensors nowadays might approximate its magnitude while running outside the lab. The time-discrete axial peak tibial acceleration (APTA) has been proposed as a good surrogate that can be measured using wearable accelerometers in the field. This paper explores the hypothesis that applying machine learning to time continuous data (generated from bilateral tri-axial shin mounted accelerometers) would result in a more accurate estimation of the VILR. Therefore, the purpose of this study was to evaluate the performance of accelerometer-based predictions of the VILR with various machine learning models trained on data of 93 rearfoot runners. A subject-dependent gradient boosted regression trees (XGB) model provided the most accurate estimates (mean absolute error: 5.39 +/- 2.04 BW.s(-1), mean absolute percentage error: 6.08%). A similar subject-independent model had a mean absolute error of 12.41 +/- 7.90 BW.s(-1) (mean absolute percentage error: 11.09%). All of our models had a stronger correlation with the VILR than the APTA (p < 0.01), indicating that multiple 3D acceleration features in a learning setting showed the highest accuracy in predicting the lab-based impact loading compared to APTA
    • 