1,704 research outputs found
Improving the Performance of Low Voltage Networks by an Optimized Unbalance Operation of Three-Phase Distributed Generators
This work focuses on using the full potential of PV inverters in order to improve the efficiency of low voltage networks. More specifically, the independent per-phase control capability of PV three-phase four-wire inverters, which are able to inject different active and reactive powers in each phase, in order to reduce the system phase unbalance is considered. This new operational procedure is analyzed by raising an optimization problem which uses a very accurate modelling of European low voltage networks. The paper includes a comprehensive quantitative comparison of the proposed strategy with two state-of-the-art methodologies to highlight the obtained benefits. The achieved results evidence that the proposed independent per-phase control of three-phase PV inverters improves considerably the network performance contributing to increase the penetration of renewable energy sources.Ministerio de EconomÃa y Competitividad ENE2017-84813-R, ENE2014-54115-
Power quality and electromagnetic compatibility: special report, session 2
The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems.
Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages).
The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks:
Block 1: Electric and Magnetic Fields, EMC, Earthing systems
Block 2: Harmonics
Block 3: Voltage Variation
Block 4: Power Quality Monitoring
Two Round Tables will be organised:
- Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13)
- Reliability Benchmarking - why we should do it? What should be done in future? (RT 15
Ancillary Services in Hybrid AC/DC Low Voltage Distribution Networks
In the last decade, distribution systems are experiencing a drastic transformation
with the advent of new technologies. In fact, distribution networks are no longer passive
systems, considering the current integration rates of new agents such as distributed generation,
electrical vehicles and energy storage, which are greatly influencing the way these systems are
operated. In addition, the intrinsic DC nature of these components, interfaced to the AC system
through power electronics converters, is unlocking the possibility for new distribution topologies
based on AC/DC networks. This paper analyzes the evolution of AC distribution systems,
the advantages of AC/DC hybrid arrangements and the active role that the new distributed agents
may play in the upcoming decarbonized paradigm by providing different ancillary services.Ministerio de EconomÃa y Competitividad ENE2017-84813-RUnión Europea (Programa Horizonte 2020) 76409
Noise Sources, Effects and Countermeasures in Narrowband Power-Line Communications Networks: A Practical Approach
The integration of Distributed Generation, Electric Vehicles, and storage without compromising the quality of the power delivery requires the deployment of a communications overlay that allows monitoring and controlling low voltage networks in almost real time. Power Line Communications are gaining momentum for this purpose since they present a great trade-off between economic and technical features. However, the power lines also represent a harsh communications medium which presents different problems such as noise, which is indeed affected by Distributed Generation, Electric Vehicles, and storage. This paper provides a comprehensive overview of the types of noise that affects Narrowband Power Line Communications, including normative noises, noises coming from common electronic devices measured in actual operational power distribution networks, and noises coming from photovoltaic inverters and electric vehicle charging spots measured in a controlled environment. The paper also reviews several techniques to mitigate the effects of noise, paying special attention to passive filtering, as for being one of the most widely used solution to avoid this kind of problems in the field. In addition, the paper presents a set of tests carried out to evaluate the impact of some representative noises on Narrowband Power Line Communications network performance, as well as the effectiveness of different passive filter configurations to mitigate such an impact. In addition, the considered sources of noise can also bring value to further improve PLC communications in the new scenarios of the Smart Grid as an input to theoretical models or simulations.This work has been partly funded by the Spanish Ministry of Economy and Competitiveness through the National Program for Research Aimed at the Challenges of Society under the project OSIRIS (RTC-2014-1556-3) and through the network of excellence REDYD2050 (ENE2015-70032-REDT)
Noise Sources, Effects and Countermeasures in Narrowband Power-Line Communications Networks: A Practical Approach
The integration of Distributed Generation, Electric Vehicles, and storage without compromising the quality of the power delivery requires the deployment of a communications overlay that allows monitoring and controlling low voltage networks in almost real time. Power Line Communications are gaining momentum for this purpose since they present a great trade-off between economic and technical features. However, the power lines also represent a harsh communications medium which presents different problems such as noise, which is indeed affected by Distributed Generation, Electric Vehicles, and storage. This paper provides a comprehensive overview of the types of noise that affects Narrowband Power Line Communications, including normative noises, noises coming from common electronic devices measured in actual operational power distribution networks, and noises coming from photovoltaic inverters and electric vehicle charging spots measured in a controlled environment. The paper also reviews several techniques to mitigate the effects of noise, paying special attention to passive filtering, as for being one of the most widely used solution to avoid this kind of problems in the field. In addition, the paper presents a set of tests carried out to evaluate the impact of some representative noises on Narrowband Power Line Communications network performance, as well as the effectiveness of different passive filter configurations to mitigate such an impact. In addition, the considered sources of noise can also bring value to further improve PLC communications in the new scenarios of the Smart Grid as an input to theoretical models or simulations.This work has been partly funded by the Spanish Ministry of Economy and Competitiveness through the National Program for Research Aimed at the Challenges of Society under the project OSIRIS (RTC-2014-1556-3) and through the network of excellence REDYD2050 (ENE2015-70032-REDT)
Recommended from our members
Energy storage sizing for low-inertia microgrids, and lessons learned from a potential microgrid
The coordinated control of multiple distributed generators in a microgrid and the preservation of adequate system inertia in real-time operations are some of the principal technical challenges for stable microgrid operation. One issue in particular pertains to grid-tied inverters, which, as mandated by present standards, are only permitted to operate at unity power factor, thereby requiring the microgrid’s synchronous generators to operate at a low power factor. This behavior accordingly introduces ramifications by limiting the generator’s active power output, which would compromise frequency and voltage stability margins. Consideration is also given to the effect of line impedances, since interconnecting microgrid lines can be described by a variety of X/R ratios that affect the control and flow of active and reactive power. Moreover, the absence of a stiff grid presents control challenges for grid-tied inverters due to the inverters’ tendency to regulate the voltage at the point of common coupling. These same inverters also jeopardize microgrid stability due to their low equivalent inertia as traditional forms of generation (i.e., spinning sources) become displaced by inertia-less inverters. Because of this low microgrid inertia, fluctuations in the output power of renewable energy sources or changes in local load levels may lead to power quality or frequency/voltage stability concerns. Therefore, energy storage sizing is investigated in this dissertation, as it is closely related to the stability analysis of microgrids. Furthermore, an existing residential community (in Austin, TX) described by a moderate penetration of photovoltaic sources and electric vehicle charging is considered, and the implications of said community being retrofitted to a microgrid are examined.Electrical and Computer Engineerin
- …