    Capacitor Mismatch Calibration Technique to Improve the SFDR of 14-Bit SAR ADC

    Get PDF
    This paper presents mismatch calibration technique to improve the SFDR in a 14-bit successive approximation register (SAR) analog-to-digital converter (ADC) for wearable electronics application. Behavioral Monte-Carlo simulations are applied to demonstrate the effect of the proposed method where no complex digital calibration algorithm or auxiliary calibration DAC needed. Simulation results show that with a mismatch error typical of modern technology, the SFDR is enhanced by more than 20 dB with the proposed technique for a 14-bit SAR ADC

    Digital Background Self-Calibration Technique for Compensating Transition Offsets in Reference-less Flash ADCs

    Get PDF
    This Dissertation focusses on proving that background calibration using adaptive algorithms are low-cost, stable and effective methods for obtaining high accuracy in flash A/D converters. An integrated reference-less 3-bit flash ADC circuit has been successfully designed and taped out in UMC 180 nm CMOS technology in order to prove the efficiency of our proposed background calibration. References for ADC transitions have been virtually implemented built-in in the comparators dynamic-latch topology by a controlled mismatch added to each comparator input front-end. An external very simple DAC block (calibration bank) allows control the quantity of mismatch added in each comparator front-end and, therefore, compensate the offset of its effective transition with respect to the nominal value. In order to assist to the estimation of the offset of the prototype comparators, an auxiliary A/D converter with higher resolution and lower conversion speed than the flash ADC is used: a 6-bit capacitive-DAC SAR type. Special care in synchronization of analogue sampling instant in both ADCs has been taken into account. In this thesis, a criterion to identify the optimum parameters of the flash ADC design with adaptive background calibration has been set. With this criterion, the best choice for dynamic latch architecture, calibration bank resolution and flash ADC resolution are selected. The performance of the calibration algorithm have been tested, providing great programmability to the digital processor that implements the algorithm, allowing to choose the algorithm limits, accuracy and quantization errors in the arithmetic. Further, systematic controlled offset can be forced in the comparators of the flash ADC in order to have a more exhaustive test of calibration

    Background Calibration of a 6-Bit 1Gsps Split-Flash ADC

    Get PDF
    In this MS thesis, a redundant flash analog-to-digital converter (ADC) using a ``Split-ADC\u27 calibration structure and lookup-table-based correction is presented. ADC input capacitance is minimized through use of small, power efficient comparators; redundancy is used to tolerate the resulting large offset voltages. Correction of errors and estimation of calibration parameters are performed continuously in the background in the digital domain. The proposed flash ADC has an effective-number-of-bits (ENOB) of 6-bits and is designed for a target sampling rate of 1Gs/s in 180nm CMOS. The calibration algorithm described has been simulated in MATLAB and an FPGA implementation has been investigated

    Pipeline ADC with a Nonlinear Gain Stage and Digital Correction

    Get PDF
    The goal of this work was to design a pipeline analog to digital converter that can be calibrated and corrected in the digital domain. The scope of this work included the design, simulation and layout of major analog design blocks. The design uses an open loop gain stage to reduce power consumption, increase speed and relax small process size design requirements. These nonlinearities are corrected using a digital correction algorithm implemented in MATLAB

    All Digital, Background Calibration for Time-Interleaved and Successive Approximation Register Analog-to-Digital Converters

    Get PDF
    The growth of digital systems underscores the need to convert analog information to the digital domain at high speeds and with great accuracy. Analog-to-Digital Converter (ADC) calibration is often a limiting factor, requiring longer calibration times to achieve higher accuracy. The goal of this dissertation is to perform a fully digital background calibration using an arbitrary input signal for A/D converters. The work presented here adapts the cyclic Split-ADC calibration method to the time interleaved (TI) and successive approximation register (SAR) architectures. The TI architecture has three types of linear mismatch errors: offset, gain and aperture time delay. By correcting all three mismatch errors in the digital domain, each converter is capable of operating at the fastest speed allowed by the process technology. The total number of correction parameters required for calibration is dependent on the interleaving ratio, M. To adapt the Split-ADC method to a TI system, 2M+1 half-sized converters are required to estimate 3(2M+1) correction parameters. This thesis presents a 4:1 Split-TI converter that achieves full convergence in less than 400,000 samples. The SAR architecture employs a binary weight capacitor array to convert analog inputs into digital output codes. Mismatch in the capacitor weights results in non-linear distortion error. By adding redundant bits and dividing the array into individual unit capacitors, the Split-SAR method can estimate the mismatch and correct the digital output code. The results from this work show a reduction in the non-linear distortion with the ability to converge in less than 750,000 samples

    DIGITALLY ASSISTED TECHNIQUES FOR NYQUIST RATE ANALOG-to-DIGITAL CONVERTERS

    Get PDF
    With the advance of technology and rapid growth of digital systems, low power high speed analog-to-digital converters with great accuracy are in demand. To achieve high effective number of bits Analog-to-Digital Converter(ADC) calibration as a time consuming process is a potential bottleneck for designs. This dissertation presentsa fully digital background calibration algorithm for a 7-bit redundant flash ADC using split structure and look-up table based correction. Redundant comparators are used in the flash ADC design of this work in order to tolerate large offset voltages while minimizing signal input capacitance. The split ADC structure helps by eliminating the unknown input signal from the calibration path. The flash ADC has been designed in 180nm IBM CMOS technology and fabricated through MOSIS. This work was supported by Analog Devices, Wilmington,MA. While much research on ADC design has concentrated on increasing resolution and sample rate, there are many applications (e.g. biomedical devices and sensor networks) that do not require high performance but do require low power energy efficient ADCs. This dissertation also explores on design of a low quiescent current 100kSps Successive Approximation (SAR) ADC that has been used as an error detection ADC for an automotive application in 350nm CD (CMOS-DMOS) technology. This work was supported by ON Semiconductor Corp, East Greenwich,RI

    A 14-bit 250 MS/s IF Sampling Pipelined ADC in 180 nm CMOS Process

    Get PDF
    This paper presents a 14-bit 250 MS/s ADC fabricated in a 180 nm CMOS process, which aims at optimizing its linearity, operating speed, and power efficiency. The implemented ADC employs an improved SHA with parasitic optimized bootstrapped switches to achieve high sampling linearity over a wide input frequency range. It also explores a dedicated foreground calibration to correct the capacitor mismatches and the gain error of residue amplifier, where a novel configuration scheme with little cost for analog front-end is developed. Moreover, a partial non-overlapping clock scheme associated with a high-speed reference buffer and fast comparators is proposed to maximize the residue settling time. The implemented ADC is measured under different input frequencies with a sampling rate of 250 MS/s and it consumes 300 mW from a 1.8 V supply. For 30 MHz input, the measured SFDR and SNDR of the ADC is 94.7 dB and 68.5 dB, which can remain over 84.3 dB and 65.4 dB for up to 400 MHz. The measured DNL and INL after calibration are optimized to 0.15 LSB and 1.00 LSB, respectively, while the Walden FOM at Nyquist frequency is 0.57 pJ/step

    A Low-Power, Reconfigurable, Pipelined ADC with Automatic Adaptation for Implantable Bioimpedance Applications

    Get PDF
    Biomedical monitoring systems that observe various physiological parameters or electrochemical reactions typically cannot expect signals with fixed amplitude or frequency as signal properties can vary greatly even among similar biosignals. Furthermore, advancements in biomedical research have resulted in more elaborate biosignal monitoring schemes which allow the continuous acquisition of important patient information. Conventional ADCs with a fixed resolution and sampling rate are not able to adapt to signals with a wide range of variation. As a result, reconfigurable analog-to-digital converters (ADC) have become increasingly more attractive for implantable biosensor systems. These converters are able to change their operable resolution, sampling rate, or both in order convert changing signals with increased power efficiency. Traditionally, biomedical sensing applications were limited to low frequencies. Therefore, much of the research on ADCs for biomedical applications focused on minimizing power consumption with smaller bias currents resulting in low sampling rates. However, recently bioimpedance monitoring has become more popular because of its healthcare possibilities. Bioimpedance monitoring involves injecting an AC current into a biosample and measuring the corresponding voltage drop. The frequency of the injected current greatly affects the amplitude and phase of the voltage drop as biological tissue is comprised of resistive and capacitive elements. For this reason, a full spectrum of measurements from 100 Hz to 10-100 MHz is required to gain a full understanding of the impedance. For this type of implantable biomedical application, the typical low power, low sampling rate analog-to-digital converter is insufficient. A different optimization of power and performance must be achieved. Since SAR ADC power consumption scales heavily with sampling rate, the converters that sample fast enough to be attractive for bioimpedance monitoring do not have a figure-of-merit that is comparable to the slower converters. Therefore, an auto-adapting, reconfigurable pipelined analog-to-digital converter is proposed. The converter can operate with either 8 or 10 bits of resolution and with a sampling rate of 0.1 or 20 MS/s. Additionally, the resolution and sampling rate are automatically determined by the converter itself based on the input signal. This way, power efficiency is increased for input signals of varying frequency and amplitude
    • …