8 research outputs found

    Efficient design of precision medical robotics

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.Cataloged from student-submitted PDF version of thesis.Includes bibliographical references (p. 106-114).Medical robotics is increasingly demonstrating the potential to improve patient care through more precise interventions. However, taking inspiration from industrial robotics has often resulted in large, sometimes cumbersome designs, which represent high capital and per procedure expenditures, as well as increased procedure times. This thesis proposes and demonstrates an alternative model and method for developing economical, appropriately scaled medical robots that improve care and efficiency, while moderating costs. Key to this approach is a structured design process that actively reduces complexity. A selected medical procedure is decomposed into discrete tasks which are then separated into those that are conducted satisfactorily and those where the clinician encounters limitations, often where robots' strengths would be complimentary. Then by following deterministic principles and with continual user participation, prototyping and testing, a system can be designed that integrates into and assists with current procedures, rather than requiring a completely new protocol. This model is expected to lay the groundwork for increasing the use of hands-on technology in interventional medicine.by Nevan Clancy Hanumara.Ph.D

    An Open-Source 7-Axis, Robotic Platform to Enable Dexterous Procedures within CT Scanners

    Full text link
    This paper describes the design, manufacture, and performance of a highly dexterous, low-profile, 7 Degree-of-Freedom (DOF) robotic arm for CT-guided percutaneous needle biopsy. Direct CT guidance allows physicians to localize tumours quickly; however, needle insertion is still performed by hand. This system is mounted to a fully active gantry superior to the patient's head and teleoperated by a radiologist. Unlike other similar robots, this robot's fully serial-link approach uses a unique combination of belt and cable drives for high-transparency and minimal-backlash, allowing for an expansive working area and numerous approach angles to targets all while maintaining a small in-bore cross-section of less than 16cm216cm^2. Simulations verified the system's expansive collision free work-space and ability to hit targets across the entire chest, as required for lung cancer biopsy. Targeting error is on average <1mm<1mm on a teleoperated accuracy task, illustrating the system's sufficient accuracy to perform biopsy procedures. The system is designed for lung biopsies due to the large working volume that is required for reaching peripheral lung lesions, though, with its large working volume and small in-bore cross-sectional area, the robotic system is effectively a general-purpose CT-compatible manipulation device for percutaneous procedures. Finally, with the considerable development time undertaken in designing a precise and flexible-use system and with the desire to reduce the burden of other researchers in developing algorithms for image-guided surgery, this system provides open-access, and to the best of our knowledge, is the first open-hardware image-guided biopsy robot of its kind.Comment: 8 pages, 9 figures, final submission to IROS 201

    Design and Development of a Surgical Robot for Needle-Based Medical Interventions

    Get PDF
    Lung cancer is the leading cause of cancer related deaths. If diagnosed in a timely manner, the treatment of choice is surgical resection of the cancerous lesions followed by radiotherapy. However, surgical resection may be too invasive for some patients due to old age or weakness. An alternative is minimally invasive needle-based interventions for cancer diagnosis and treatment. This project describes the design, analysis, development and experimental evaluation of a modular, compact, patient-mounted robotic manipulator for lung cancer diagnosis and treatment. In this regard, a novel parallel Remote Centre of Motion (RCM) mechanism is proposed for minimally invasive delivery of needle-based interventions. The proposed robot provides four degrees of freedom (DOFs) to orient and move a surgical needle within a spherical coordinate system. There is an analytical solution for the kinematics of the proposed parallel mechanism and the end-effectors motion is well-conditioned within the required workspace. The RCM is located beneath the skin surface to minimize the invasiveness of the surgical procedure while providing the required workspace to target the cancerous lesions. In addition, the proposed robot benefits from a design capable of measuring the interaction forces between the needle and the tissue. The experimental evaluation of the robot has proved its capability to accurately orient and move a surgical needle within the required workspace. Although this robotic system has been designed for the treatment of lung cancer, it is capable of performing other procedures in the thoracic or abdominal cavity such as liver cancer diagnosis and treatment

    Image-guided robots for dot-matrix tumor ablation

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.Cataloged from PDF version of thesis.Includes bibliographical references (p. 203-208).Advances in medical imaging now provides detailed images of solid tumors inside the body and miniaturized energy delivery systems enable tumor destruction through local heating powered by a thin electrode. However, the use of thermal ablation as a first line of treatment is limited due to the difficulty in accurately matching a desired treatment and a limited region of active heating around an electrode. The purpose of this research is to identify and quantify the current limitations of image-guided interventional procedures and subsequently develop a procedure and devices to enable accurate and efficient execution of image-based interventional plans and thus ablation of a tumor of any shape with minimal damage to surrounding tissue. Current limitations of probe placement for ablation therapy were determined by a detailed retrospective study of 50 representative CT-guided procedures. On average, 21 CT scans were performed for a given procedure (range 11-38), with the majority devoted to needle orientation and insertion (mean number of scans was 54%) and trajectory planning (mean number of scans was 19%). A regression analysis yielded that smaller and deeper lesions were associated with a higher number of CT scans for needle orientation and insertion; highlighting the difficulty in targeting. Another challenge identified was repositioning the instrument distal tip within tissue. The first robot is a patient-mounted device that aligns an instrument along a desired trajectory via two motor-actuated concentric, crossed, and partially nested hoops. A carriage rides in the hoops and grips and inserts an instrument via a two degree-of-freedom friction drive. An imagebased point-and-click user interface relates appropriate clicks on the medical images to robot commands. Mounting directly on the patient provides a sufficiently stable and safe platform for actuation and eliminates the need to compensate for chest motion; thereby reducing the cost and complexity compared to other devices. Phantom experiments in a realistic clinical setting demonstrated a mean targeting accuracy of 3.5 mm with an average of five CT scans. The second robot is for repositioning the distal tip of a medical instrument to adjacent points within tissue. The steering mechanism is based on the concept of substantially straightening a pre-curved Nitinol stylet by retracting it into a concentric outer cannula, and re-deploying it at different axial and rotational cannula positions. The proximal end of the cannula is attached to the distal end of a screw-spline that enables it to be translated and rotated with respect to the casing. Translation of the stylet relative to the cannula is achieved with a second concentric, nested smaller diameter screw that is constrained to rotate with the cannula. The robot mechanism is compatible with the CT images, light enough to be supported on a patient's chest or attached to standard stereotactic frames. Targeting experiments in a gelatin phantom demonstrated a mean targeting error of 1.8 mm between the stylet tip and that predicted with a kinematic model. Ultimately, these types of systems are envisioned being used together as part of a highly dexterous patient-mounted positioning platform that can accurately perform ablation of large and irregularly shaped tumors inside medical imaging machines - offering the potential to replace expensive and traumatic surgeries with minimally invasive out-patient procedures.by Conor James Walsh.Ph.D

    Multi-probe robotic positioner for cryoablation in MRI

    Get PDF
    Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.Cataloged from PDF version of thesis.Includes bibliographical references (p. 116-118).This thesis describes the design of a guidance device for faster and more accurate targeting of multiple probes during cryoablation and other percutaneous interventions performed in closed bore magnetic resonance (MR) imaging systems. The device is intended to be mounted onto a Siemens 110 mm MR loop coil that rests on the patient and contains a cable driven two-degree-of- freedom spherical mechanism that orientates the intervention probes about a remote center of motion located 15 mm above the skin entry point. A carriage, pulled by strong and low stretch cables, can position up to three intervention probes as it travels on a rotating hoop. Its motion is constrained by a custom designed roller bearing to minimize friction. A thumbscrew fastened latch allows a probe to be engaged in a guide that constrains the probe along a specific trajectory. The probe can also be disengaged from its track, freeing it to move with respiration and enabling the guide to be repositioned for another probe to be inserted. Compact MR compatible piezoelectric motors are used to actuate the system. A prototype was built from 3D printed ABS plastic as a proof of concept. Bench level evaluation demonstrated that each component of the device performs according to the design specifications. The device performance was characterized by analyzing still images taken before and after movement, which yielded sub-degree accuracy, sub-degree repeatability near vertical position, and an incremental step resolution of at least 0.5 degree. Upon further developments of the registration and calibration modules in 3D slicer to interface the robot with image data, evaluation of the device in MRI will be performed.by Faye Y. Wu.S.M

    下腹部を対象とした極細針によるCTガイド下高正確度穿刺プランニング

    Get PDF
    早大学位記番号:新8149早稲田大

    Motion compensation and computer guidance for percutenaneous abdominal interventions

    Get PDF

    Development and evaluation of a new image-based user interface for robot-assisted needle placements with the robopsy system

    No full text
    The main challenges of Computed Tomography (CT)-guided organ puncture are the mental registration of the medical imaging data with the patient anatomy, required when planning a trajectory, and the subsequent precise insertion of a needle along it. An interventional telerobotic system, such as Robopsy, enables precise needle insertion, however, in order to minimize procedure time and number of CT scans, this system should be driven by an interface that is directly integrated with the medical imaging data. In this study we have developed and evaluated such an interface that provides the user with a point-and-click functionality for specifying the desired trajectory, segmenting the needle and automatically calculating the insertion parameters (angles and depth). In order to highlight the advantages of such an interface, we compared robotic-assisted targeting using the old interface (non-image-based) where the path planning was performed on the CT console and transferred manually to the interface with the targeting procedure using the new interface (image-based). We found that the mean procedure time (n=5) was 22±5 min (non-image-based) and 19±1 min (image-based) with a mean number of CT scans of 6±1 (non-image-based) and 5±1 (image-based). Although the targeting experiments were performed in gelatin with homogenous properties our results indicate that an image-based interface can reduce procedure time as well as number of CT scans for percutaneous needle biopsies