81 research outputs found

    A microgripper for single cell manipulation

    Get PDF
    This thesis presents the development of an electrothermally actuated microgripper for the manipulation of cells and other biological particles. The microgripper has been fabricated using a combination of surface and bulk micromachining techniques in a three mask process. All of the fabrication details have been chosen to enable a tri-layer, polymer (SU8) - metal (Au) - polymer (SU8), membrane to be released from the substrate stress free and without the need for sacrificial layers. An actuator design, which completely eliminates the parasitic resistance of the cold arm, is presented. When compared to standard U-shaped actuators, it improves the thermal efficiency threefold. This enables larger displacements at lower voltages and temperatures. The microgripper is demonstrated in three different configurations: normally open mode, normally closed mode, and normally open/closed mode. It has-been modelled using two coupled analytical models - electrothermal and thermomechanical - which have been custom developed for this application. Unlike previously reported models, the electrothermal model presented here includes the heat exchange between hot and cold arms of the actuators that are separated by a small air gap. A detailed electrothermomechanical characterisation of selected devices has permitted the validation of the models (also performed using finite element analysis) and the assessment of device performance. The device testing includes electrical, deflection, and temperature measurements using infrared (IR) thermography, its use in polymeric actuators reported here for the first time. Successful manipulation experiments have been conducted in both air and liquid environments. Manipulation of live cells (mice oocytes) in a standard biomanipulation station has validated the microgripper as a complementary and unique tool for the single cell experiments that are to be conducted by future generations of biologists in the areas of human reproduction and stem cell research

    Dynamic modelling for thermal micro-actuators using thermal networks.

    No full text
    International audienceThermal actuators are extensively used in microelectromechanical systems (MEMS). Heat transfer through and around these microstructures are very complex. Knowing and controlling them in order to improve the performance of the micro-actuator, is currently a great challenge. This paper deals with this topic and proposes a dynamic thermal modelling of thermal micro-actuators. Thermal problems may be modelled using electrical analogy. However, current equivalent electrical models (thermal networks) are generally obtained considering only heat transfers through the thickness of structures having considerable height and length in relation to width (walls). These models cannot be directly applied to micro-actuators. In fact, microactuator congurations are based on 3D beam structures, and heat transfers occur through and around length. New dynamic and static thermal networks are then proposed in this paper. The validities of both types of thermal networks have been studied. They are successfully validated by comparison with nite elements simulation and analytical calculations

    Grasping and releasing agarose micro beads in water drops

    Get PDF
    The micromanipulation of micro objects is nowadays the focus of several investigations, specially in biomedical applications. Therefore, some manipulation tasks are required to be in aqueous environment and become more challenging because they depend upon observation and actuation methods that are compatible with MEMS Technology based micromanipulators. This paper describes how three grasping-releasing based tasks have been successfully applied to agarose micro beads whose average size is about 60 \u3bcm: (i) the extraction of a single micro bead from a water drop; (ii) the insertion of a single micro bead into the drop; (iii) the grasping of a single micro bead inside the drop. The success of the performed tasks rely on the use of a microgripper previously designed, fabricated, and tested

    Micro motion amplification – A Review

    Get PDF
    Many motion-active materials have recently emerged, with new methods of integration into actuator components and systems-on-chip. Along with established microprocessors, interconnectivity capabilities and emerging powering methods, they offer a unique opportunity for the development of interactive millimeter and micrometer scale systems with combined sensing and actuating capabilities. The amplification of nanoscale material motion to a functional range is a key requirement for motion interaction and practical applications, including medical micro-robotics, micro-vehicles and micro-motion energy harvesting. Motion amplification concepts include various types of leverage, flextensional mechanisms, unimorphs, micro-walking /micro-motor systems, and structural resonance. A review of the research state-of-art and product availability shows that the available mechanisms offer a motion gain in the range of 10. The limiting factor is the aspect ratio of the moving structure that is achievable in the microscale. Flexures offer high gains because they allow the application of input displacement in the close vicinity of an effective pivotal point. They also involve simple and monolithic fabrication methods allowing combination of multiple amplification stages. Currently, commercially available motion amplifiers can provide strokes as high as 2% of their size. The combination of high-force piezoelectric stacks or unimorph beams with compliant structure optimization methods is expected to make available a new class of high-performance motion translators for microsystems

    The effects of cold arm width and metal deposition on the performance of a U-Beam electrothermal MEMS microgripper for biomedical applications

    Get PDF
    Microelectromechanical systems (MEMS) have established themselves within various fields dominated by high-precision micromanipulation, with the most distinguished sectors being the microassembly, micromanufacturing and biomedical ones. This paper presents a horizontal electrothermally actuated 'hot and cold arm' microgripper design to be used for the deformability study of human red blood cells (RBCs). In this study, the width and layer composition of the cold arm are varied to investigate the effects of dimensional and material variation of the cold arm on the resulting temperature distribution, and ultimately on the achieved lateral displacement at the microgripper arm tips. The cold arm widths investigated are 14 μm, 30 μm, 55 μm, 70 μm and 100 μm. A gold layer with a thin chromium adhesion promoter layer is deposited on the top surface of each of these cold arms to study its effect on the performance of the microgripper. The resultant ten microgripper design variants are fabricated using a commercially available MEMS fabrication technology known as a silicon-on-insulator multi-user MEMS process (SOIMUMPs)TM. This process results in an overhanging 25 μm thick single crystal silicon microgripper structure having a low aspect ratio (width:thickness) value compared to surface micromachined structures where structural thicknesses are of the order of 2 μm. Finite element analysis was used to numerically model the microgripper structures and coupled electrothermomechanical simulations were implemented in CoventorWare ®. The numerical simulations took into account the temperature dependency of the coefficient of thermal expansion, the thermal conductivity and the electrical conductivity properties in order to achieve more reliable results. The fabricated microgrippers were actuated under atmospheric pressure and the experimental results achieved through optical microscopy studies conformed with those predicted by the numerical models. The gap opening and the temperature rise at the cell gripping zone were also compared for the different microgripper structures in this work, with the aim of identifying an optimal microgripper design for the deformability characterisation of RBCs.peer-reviewe

    The static and dynamic response of SU-8 electrothermal microgrippers of varying thickness

    Get PDF
    This work presents an investigation into the effect on dynamic response of SU-8 microgrippers due to varying thickness, and subsequent validation via COMSOL Multiphysics simulations and thermal camera profiling during actuation. The tweezer-like microgrippers can easily manipulate, with a high degree of control, cells and particles with diameters as small as 10 μm, without using an impractical operating voltage or generating excessive heat. However, in order to fully exploit the versatility of the devices, their response characteristics must be fully understood as material and/or dimension parameters change. Therefore an investigation took place to determine the effects of device thickness on functionality of the device, including the drive current required to actuate the gripper and the speed of actuation. Furthermore, an infrared camera was used to characterise the thermal response of the device. Finally, a simulation of the temperature profile and deflection dimension has been developed in order to verify the findings and further investigate and predict the effects of design variations

    Design, characterisation and testing of SU8 polymer based electrothermal microgrippers

    Get PDF
    Microassembly systems are designed to combine micro-component parts with high accuracy. These micro-components are fabricated using different manufacturing processes in sizes of several micrometers. This technology is essential to produce miniaturised devices and equipment, especially those built from parts requiring different fabrication procedures. The most important task in microassembly systems is the manipulator, which should have the ability to handle and control micro-particles. Different techniques have been developed to carry out this task depending on the application, required accuracy, and cost. In this thesis, the most common methods are identified and briefly presented, and some advantages and disadvantages are outlined. A microgripper is the most important device utilized to handle micro-objects with high accuracy. However, it is a device that can be used only in sequential microassembly techniques. It has the potential to become the most important tool in the field of micro-robotics, research and development, and assembly of parts with custom requirements. Different actuation mechanisms are employed to design microgrippers such as electromagnetic force, electrostatic force, piezoelectric effect, and electrothermal expansions. Also, different materials are used to fabricate these microgrippers, for example metals, silicon, and polymers such as SU-8. To investigate the limitation and disadvantages of the conventional SU-8 electrothermal based microgrippers, different devices designed and fabricated at IMT, Romania, were studied. The results of these tests showed a small end-effector displacement and short cycling on/off (lifetime). In addition, the actuator part of these microgrippers was deformed after each operation, which results in reduced displacement and inconsistent openings at off state every time it was operated in a power ON/OFF cycle. One of these limitations was caused by the existence of conductors in arms of the end-effectors. These conductor designs have two disadvantages: firstly, it raises temperature in the arms and causing an expansion in the opposite direction of the desired displacement. Secondly, since the conductors pass through the hinges, they should be designed wide enough to reduce the conductor resistance as much as possible. Therefore, the wider the hinges are, the higher the in-plane stiffness and the less out of plane deflection. As a result, it increases the reaction force of the arm reducing the effect of deformation. Based on these limitations a new actuatorstructure of L-shape was proposed to reduce the effects of these drawbacks. This actuator has no conductor in the hinges or the arms of the end-effectors which reduce limitation on the hinge width. . In addition, a further development of this actuator was proposed to increase the stiffness of the actuator by doubling its thickness compared with the other parts of the griper. The results of this actuator proved the improvement in performance and reduction of the actuator deformation. This new actuator structure was used to design several different microgrippers with large displacement and suitable for a wide range of applications. Demonstrations of the capabilities of the microgrippers to be used in microassembly are presented. In addition, a novel tri-directional microactuator is proposed in this thesis. This actuator’s end-effector is capable of displacements in three different directions. This actuator was used with the other designs to develop a novel three-arm (three fingers) multidirectional microgripper. To study the microgripper displacement as a function to the heater temperature, the TCR of the conductor layer of each device was measured. Because different configurations of conductor layers were studied, a significant effect of the metal layer structure on TCR was discovered. The TCR value of gold film is reduced significantly by adding the chromium layers below and about it which were used to improve the adhesion between the gold film and the SU layers. In this thesis, a new method based on a robotic system was developed to characterise these microgrippers and to study the steady state, dynamic response, and reliability (lifetime cycling on/off). An electronic interface was developed and integrated to the robotic system to control and drive the microgrippers. This new system was necessary to carry out automated testing of the microgrippers with accurate and reliable results. Four different new groups of microgrippers were designed and studied. The first group was indirectly actuated using an L-Shaped actuator and two different actuator widths. The initial opening was 120 μm for both designs. The maximum displacement was about 140 μm for both designs. However, the actuator in the wider heater width showed more stable behavior during the cycling and the dynamic tests. The second group was based on direct actuation approach using the L-Shaped actuator. There were eight different designs based on this method with different heater conductor shape, actuator width, and arm thickness. The initial opening was 100 μm and there were different displacements for the eight designs. The study of these microgrippers proved that the actuator stiffness has a significant effect on the microgripper displacement. In addition, the shape of the heater conductor has less effect. The largest displacement achieved using this method of design was about 70 μm. The third group was designed for dual mode operation and has three different designs. The initial openings were 90 μm and 250 μm. The displacement was about 170 μm in both modes. The last microgripper design was a tri-arm design for multi-mode operation. The lifetime study of SU8 based microgrippers in this thesis was the first time such an investigation was carried out. The results of IMT designs showed that the larger is the displacement the less stable is the gripper design because of the high rection force acting on the actuators. The L-shape based microgrippers had better performance and they did not break after more than 400 cycles. In addition, the studies of static displacement and dynamic response of different designed microgripper proved that better performance of the proposed actuator can be obtained by using double thickness for the actuator as compared to the arm thickness

    Development and Force/Position control of a new Hybrid Thermo-Piezoelectric MicroGripper dedicated to micromanipulation tasks.

    No full text
    International audienceA new microgripper dedicated to micromanipulation and microassembly tasks is presented in this paper. Based on a new actuator, called thermo-piezoelectric actuator, the microgripper presents both a high range and a high positioning resolution. The principle of the microgripper is based on the combination of the thermal actuation (for the coarse positioning) and the piezoelectric actuation (for the fine positioning). In order to improve the performances of the microgripper, its actuators are modeled and a control law for both the position and the manipulation force is synthesized afterwards. A new control scheme adapted for the actuators of the hybrid thermo-piezoelectric microgripper is therefore proposed. To prove the interest of the developed microgripper and of the proposed control scheme, the control of a pick-and-release task using this microgripper is carried out. The experimental results confirm their efficiency and demonstrate that the new microgripper and the control law are well suited for micromanipulation and microassembly applications
    corecore