619 research outputs found
Recommended from our members
Quadrupedal locomotion based on a muscular activation pattern with stretch-reflex
Cyclical locomotion, such as walking, hopping and
running, is known to be generated at the spinal cord, guiding
human and animal strides over different gaits. Over the last
years, many researchers concentrated their study on the origin
of such signals, replicating them by either controlling joint
angles or torques. In this work, we use a quadruped pneumatic
robot to reproduce stable walking on a treadmill through a
muscular activation pattern. Unlike previous studies, neither
angles or torques are taken into consideration. Similarly to
biological morphology, with variating moment arms, muscles
contract rhythmically and their inherent compliance adapts
to the floor. Proportional feedback upon touching the floor
(stretch-reflex) is also tested, and its effects are explained. In the
future, this methodology can be used to produce adaptive gait
and improve current robotic by exploring interaction between
control and soft bodies.This work was aided by KAKENHI Kiban(S) 23220004 and 25540117.This is the accepted manuscript. The final version is available at http://dx.doi.org/10.1109/ROBIO.2014.7090425
Applications of EMG in Clinical and Sports Medicine
This second of two volumes on EMG (Electromyography) covers a wide range of clinical applications, as a complement to the methods discussed in volume 1. Topics range from gait and vibration analysis, through posture and falls prevention, to biofeedback in the treatment of neurologic swallowing impairment. The volume includes sections on back care, sports and performance medicine, gynecology/urology and orofacial function. Authors describe the procedures for their experimental studies with detailed and clear illustrations and references to the literature. The limitations of SEMG measures and methods for careful analysis are discussed. This broad compilation of articles discussing the use of EMG in both clinical and research applications demonstrates the utility of the method as a tool in a wide variety of disciplines and clinical fields
Computational Intelligence in Electromyography Analysis
Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG may be used clinically for the diagnosis of neuromuscular problems and for assessing biomechanical and motor control deficits and other functional disorders. Furthermore, it can be used as a control signal for interfacing with orthotic and/or prosthetic devices or other rehabilitation assists. This book presents an updated overview of signal processing applications and recent developments in EMG from a number of diverse aspects and various applications in clinical and experimental research. It will provide readers with a detailed introduction to EMG signal processing techniques and applications, while presenting several new results and explanation of existing algorithms. This book is organized into 18 chapters, covering the current theoretical and practical approaches of EMG research
Control of multifunctional prosthetic hands by processing the electromyographic signal
The human hand is a complex system, with a large number of degrees of freedom (DoFs), sensors embedded in its structure, actuators and tendons, and a complex hierarchical control. Despite this complexity, the efforts required to the user to carry out the different movements is quite small (albeit after an appropriate and lengthy training). On the contrary, prosthetic hands are just a pale replication of the natural hand, with significantly reduced grasping capabilities and no sensory information delivered back to the user. Several attempts have been carried out to develop multifunctional prosthetic devices controlled by electromyographic (EMG) signals (myoelectric hands), harness (kinematic hands), dimensional changes in residual muscles, and so forth, but none of these methods permits the "natural" control of more than two DoFs. This article presents a review of the traditional methods used to control artificial hands by means of EMG signal, in both the clinical and research contexts, and introduces what could be the future developments in the control strategy of these devices
Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
abstract: Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human–robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the highest coherence with hand movements. Our results represent a first step toward a more effective and intuitive control of myoelectric hand prostheses.View the article as published at http://journal.frontiersin.org/article/10.3389/fnbot.2016.00011/ful
Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human-robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the highest coherence with hand movements. Our results represent a first step toward a more effective and intuitive control of myoelectric hand prostheses
Stretch reflex improves rolling stability during hopping of a decerebrate system
When humans hop, attitude recovery can be observed in both the sagittal and frontal planes. While it is agreed that the brain plays an important role in leg placement, the role of low-level feedback (the stretch reflex) on frontal plane stabilization remains unclear. Seeking to better understand the contribution of the soleus stretch reflex to rolling stability, we performed experiments on a biomimetic humanoid hopping robot. Various reflex responses to touching the floor, ranging from no response to long muscle activations, were examined, and the effect of a delay upon touching the floor was also examined. We found that the stretch reflex brought the system closer to stable, straight hopping. The presence of a delay did not affect the results; both the cases with and without a delay outperformed the case without a reflex response. The results of this study highlight the importance of low-level control in locomotion for which body stabilization does not require higher-level signals.This is the accepted manuscript. The final version is available at http://iopscience.iop.org/article/10.1088/1748-3190/10/1/016008/meta;jsessionid=8394D6E9724906C836DC3624B5BF2F90.c1
- …