722 research outputs found

    Deformation-Based Abnormal Motion Detection using 3D Skeletons

    Get PDF
    In this paper, we propose a system for abnormal motion detection using 3D skeleton information, where the abnormal motion is not known a priori. To that end, we present a curve-based representation of a sequence, based on few joints of a 3D skeleton, and a deformation-based distance function. We further introduce a time-variation model that is specifically designed for assessing the quality of a motion; we refer to a distance function that is based on such a model as~\emph{motion quality distance}. The overall advantages of the proposed approach are 1) lower dimensional yet representative sequence representation and 2) a distance function that emphasizes time variation, the motion quality distance, which is a particularly important property for quality assessment. We validate our approach using a publicly available dataset, SPHERE-StairCase2014 dataset. Qualitative and quantitative results show promising performance

    Multi-set canonical correlation analysis for 3D abnormal gait behaviour recognition based on virtual sample generation

    Get PDF
    Small sample dataset and two-dimensional (2D) approach are challenges to vision-based abnormal gait behaviour recognition (AGBR). The lack of three-dimensional (3D) structure of the human body causes 2D based methods to be limited in abnormal gait virtual sample generation (VSG). In this paper, 3D AGBR based on VSG and multi-set canonical correlation analysis (3D-AGRBMCCA) is proposed. First, the unstructured point cloud data of gait are obtained by using a structured light sensor. A 3D parametric body model is then deformed to fit the point cloud data, both in shape and posture. The features of point cloud data are then converted to a high-level structured representation of the body. The parametric body model is used for VSG based on the estimated body pose and shape data. Symmetry virtual samples, pose-perturbation virtual samples and various body-shape virtual samples with multi-views are generated to extend the training samples. The spatial-temporal features of the abnormal gait behaviour from different views, body pose and shape parameters are then extracted by convolutional neural network based Long Short-Term Memory model network. These are projected onto a uniform pattern space using deep learning based multi-set canonical correlation analysis. Experiments on four publicly available datasets show the proposed system performs well under various conditions

    Analysis of 3D human gait reconstructed with a depth camera and mirrors

    Full text link
    L'évaluation de la démarche humaine est l'une des composantes essentielles dans les soins de santé. Les systèmes à base de marqueurs avec plusieurs caméras sont largement utilisés pour faire cette analyse. Cependant, ces systèmes nécessitent généralement des équipements spécifiques à prix élevé et/ou des moyens de calcul intensif. Afin de réduire le coût de ces dispositifs, nous nous concentrons sur un système d'analyse de la marche qui utilise une seule caméra de profondeur. Le principe de notre travail est similaire aux systèmes multi-caméras, mais l'ensemble de caméras est remplacé par un seul capteur de profondeur et des miroirs. Chaque miroir dans notre configuration joue le rôle d'une caméra qui capture la scène sous un point de vue différent. Puisque nous n'utilisons qu'une seule caméra, il est ainsi possible d'éviter l'étape de synchronisation et également de réduire le coût de l'appareillage. Notre thèse peut être divisée en deux sections: reconstruction 3D et analyse de la marche. Le résultat de la première section est utilisé comme entrée de la seconde. Notre système pour la reconstruction 3D est constitué d'une caméra de profondeur et deux miroirs. Deux types de capteurs de profondeur, qui se distinguent sur la base du mécanisme d'estimation de profondeur, ont été utilisés dans nos travaux. Avec la technique de lumière structurée (SL) intégrée dans le capteur Kinect 1, nous effectuons la reconstruction 3D à partir des principes de l'optique géométrique. Pour augmenter le niveau des détails du modèle reconstruit en 3D, la Kinect 2 qui estime la profondeur par temps de vol (ToF), est ensuite utilisée pour l'acquisition d'images. Cependant, en raison de réflections multiples sur les miroirs, il se produit une distorsion de la profondeur dans notre système. Nous proposons donc une approche simple pour réduire cette distorsion avant d'appliquer les techniques d'optique géométrique pour reconstruire un nuage de points de l'objet 3D. Pour l'analyse de la démarche, nous proposons diverses alternatives centrées sur la normalité de la marche et la mesure de sa symétrie. Cela devrait être utile lors de traitements cliniques pour évaluer, par exemple, la récupération du patient après une intervention chirurgicale. Ces méthodes se composent d'approches avec ou sans modèle qui ont des inconvénients et avantages différents. Dans cette thèse, nous présentons 3 méthodes qui traitent directement les nuages de points reconstruits dans la section précédente. La première utilise la corrélation croisée des demi-corps gauche et droit pour évaluer la symétrie de la démarche, tandis que les deux autres methodes utilisent des autoencodeurs issus de l'apprentissage profond pour mesurer la normalité de la démarche.The problem of assessing human gaits has received a great attention in the literature since gait analysis is one of key components in healthcare. Marker-based and multi-camera systems are widely employed to deal with this problem. However, such systems usually require specific equipments with high price and/or high computational cost. In order to reduce the cost of devices, we focus on a system of gait analysis which employs only one depth sensor. The principle of our work is similar to multi-camera systems, but the collection of cameras is replaced by one depth sensor and mirrors. Each mirror in our setup plays the role of a camera which captures the scene at a different viewpoint. Since we use only one camera, the step of synchronization can thus be avoided and the cost of devices is also reduced. Our studies can be separated into two categories: 3D reconstruction and gait analysis. The result of the former category is used as the input of the latter one. Our system for 3D reconstruction is built with a depth camera and two mirrors. Two types of depth sensor, which are distinguished based on the scheme of depth estimation, have been employed in our works. With the structured light (SL) technique integrated into the Kinect 1, we perform the 3D reconstruction based on geometrical optics. In order to increase the level of details of the 3D reconstructed model, the Kinect 2 with time-of-flight (ToF) depth measurement is used for image acquisition instead of the previous generation. However, due to multiple reflections on the mirrors, depth distortion occurs in our setup. We thus propose a simple approach for reducing such distortion before applying geometrical optics to reconstruct a point cloud of the 3D object. For the task of gait analysis, we propose various alternative approaches focusing on the problem of gait normality/symmetry measurement. They are expected to be useful for clinical treatments such as monitoring patient's recovery after surgery. These methods consist of model-free and model-based approaches that have different cons and pros. In this dissertation, we present 3 methods that directly process point clouds reconstructed from the previous work. The first one uses cross-correlation of left and right half-bodies to assess gait symmetry while the other ones employ deep auto-encoders to measure gait normality

    Fast Adaptive Reparametrization (FAR) with Application to Human Action Recognition

    Get PDF
    In this paper, a fast approach for curve reparametrization, called Fast Adaptive Reparamterization (FAR), is introduced. Instead of computing an optimal matching between two curves such as Dynamic Time Warping (DTW) and elastic distance-based approaches, our method is applied to each curve independently, leading to linear computational complexity. It is based on a simple replacement of the curve parameter by a variable invariant under specific variations of reparametrization. The choice of this variable is heuristically made according to the application of interest. In addition to being fast, the proposed reparametrization can be applied not only to curves observed in Euclidean spaces but also to feature curves living in Riemannian spaces. To validate our approach, we apply it to the scenario of human action recognition using curves living in the Riemannian product Special Euclidean space SE(3) n. The obtained results on three benchmarks for human action recognition (MSRAction3D, Florence3D, and UTKinect) show that our approach competes with state-of-the-art methods in terms of accuracy and computational cost

    Quantifying Palaeopathology Using Geometric Morphometrics

    Get PDF
    Palaeopathology is the study of disease and injury in archaeological bone. Traditional methods rely heavily on macroscopic description which can have a high degree of subjectivity and error, as well as limiting the types of research questions possible. Geometric morphometrics are a suite of shape analysis techniques and provide an opportunity to investigate possible relationships between skeletal morphological variation and disease. This thesis aims to demonstrate the potential of applying these methods in palaeopathological research and the results illustrate the benefits of using quantifiable and objective shape analysis methods in palaeopathology. The first half of the thesis discusses the use of geometric morphometrics to investigate skeletal variation to identify possible aetiological factors in the development of Schmorl's nodes and osteoarthritis. There was a strong association found between vertebral morphology and Schmorl's nodes in the lower spine. These findings have great implications for both bioarchaeological interpretation and clinical understanding of the aetiology and pathogenesis of Schmorl's nodes. Joint morphology of the proximal ulna and distal humerus was found to have no identifiable relationship with osteoarthritis, indicating that joint morphology is not a predisposing factor in elbow osteoarthritis, nor does osteoarthritis deform the joints in a systematic manner. A tentative relationship between eburnation and knee joint morphology was identified, although these results need to be verified with future research. If the association can be supported, shape analyses may provide a way for clinicians to monitor the progression of the disease. Geometric morphometrics were also shown to objectively record pathological shape deformation resulting from leprosy and residual rickets. The ability to objectively describe lesions with quantified data will greatly strengthen palaeopathology by decreasing the subjectivity and error inherent in macroscopic based methods. This thesis represents promising groundwork for the incorporation of geometric morphometrics into palaeopathological research
    corecore