10,971 research outputs found

    "Not the Usual Suspects": A Study of Factors Reducing the Effectiveness of CCTV

    Get PDF
    Previous research on the effectiveness of Closed Circuit Television (CCTV) has focused on critically assessing police and government claims that CCTV is effective in reducing crime. This paper presents a field study that investigates the relationship between CCTV system design and the performance of operator tasks. We carried out structured observations and interviews with 13 managers and 38 operators at 13 CCTV control rooms. A number of failures were identified, including the poor configuration of technology, poor quality video recordings, and a lack of system integration. Stakeholder communication was poor, and there were too many cameras and too few operators. These failures have been previously identified by researchers; however, no design improvements have been made to control rooms in the last decade. We identify a number of measures to improve operator performance, and contribute a set of recommendations for security managers and practitioners. Security Journal (2010) 23, 134-154. doi:10.1057/sj.2008.2; published online 6 October 200

    Human factors analysis, design, and evaluation of Engage, a consumer health IT application for geriatric heart failure self-care

    Get PDF
    Human factors and ergonomics (HFE) and related approaches can be used to enhance research and development of consumer-facing health IT systems, including technologies supporting the needs of people with chronic disease. We describe a multiphase HFE study of health IT supporting self-care of chronic heart failure by older adults. The study was based on HFE frameworks of "patient work" and incorporated the three broad phases of user-centered design: study or analysis; design; and evaluation. In the study phase, data from observations, interviews, surveys, and other methods were analyzed to identify gaps in and requirements for supporting heart failure self-care. The design phase applied findings from the study phase throughout an iterative process, culminating in the design of the Engage application, a product intended for continuous use over 30 days to stimulate self-care engagement, behavior, and knowledge. During the evaluation phase, we identified a variety of usability issues through expert heuristic evaluation and laboratory-based usability testing. We discuss the implications of our findings regarding heart failure self-care in older adults and the methodological challenges of rapid translational field research and development in this domain

    Electronic Health Record Optimization for Cardiac Care

    Get PDF
    Electronic health record (EHR) systems have been studied for over 30 years, and despite the benefits of information technology in other knowledge domains, progress has been slow in healthcare. A growing body of evidence suggests that dissatisfaction with EHR systems was not simply due to resistance to adoption of new technology but also due to real concerns about the adverse impact of EHRs on the delivery of patient care. Solutions for EHR improvement require an approach that combines an understanding of technology adoption with the complexity of the social and technical elements of the US healthcare system. Several studies are presented to clarify and propose a new framework to study EHR-provider interaction. Four focus areas were defined - workflow, communication, medical decision-making and patient care. Using Human Computer Interaction best practices, an EHR usability framework was designed to include a realistic clinical scenario, a cognitive walkthrough, a standardized simulated patient actor, and a portable usability lab. Cardiologists, fellows and nurse practitioners were invited to participate in a simulation to use their institution’s EHR system for a routine cardiac visit. Using a mixed methods approach, differences in satisfaction and effectiveness were identified. Cardiologists were dissatisfied with EHR functionality, and were critical of the potential impact of the communication of incorrect information, while displaying the highest level of success in completing the tasks. Fellows were slightly less dissatisfied with their EHR interaction, and demonstrated a preference for tools to improve workflow and support decision-making, and showed less success in completing the tasks in the scenario. Nurse practitioners were also dissatisfied with their EHR interaction, and cited poor organization of data, yet demonstrated more success than fellows in successful completion of tasks. Study results indicate that requirements for EHR functionality differ by type of provider. Cardiologists, cardiology fellows, and nurse practitioners required different levels of granularity of patient data for use in medical decision-making, defined different targets for communication, sought different solutions to workflow which included distribution of data input, and requested technical solutions to ensure valid and relevant patient data. These findings provide a foundation for future work to optimize EHR functionality

    M-health review: joining up healthcare in a wireless world

    Get PDF
    In recent years, there has been a huge increase in the use of information and communication technologies (ICT) to deliver health and social care. This trend is bound to continue as providers (whether public or private) strive to deliver better care to more people under conditions of severe budgetary constraint

    ALT-C 2010 - Conference Proceedings

    Get PDF

    Usability analysis of contending electronic health record systems

    Get PDF
    In this paper, we report measured usability of two leading EHR systems during procurement. A total of 18 users participated in paired-usability testing of three scenarios: ordering and managing medications by an outpatient physician, medicine administration by an inpatient nurse and scheduling of appointments by nursing staff. Data for audio, screen capture, satisfaction rating, task success and errors made was collected during testing. We found a clear difference between the systems for percentage of successfully completed tasks, two different satisfaction measures and perceived learnability when looking at the results over all scenarios. We conclude that usability should be evaluated during procurement and the difference in usability between systems could be revealed even with fewer measures than were used in our study. © 2019 American Psychological Association Inc. All rights reserved.Peer reviewe
    corecore