2,239 research outputs found

    Compound Radar Approach for Breast Imaging

    Get PDF

    Coherence function-encoded optical palpation

    Get PDF
    Funding: Australian Research Council, the National Health and Medical Research Council (Australia), OncoRes Medical, Australia.Optical palpation maps stress at the surface of biological tissue into 2D images. It relies on measuring surface deformation of a compliant layer, which to date has been performed with optical coherence tomography (OCT). OCT-based optical palpation holds promise for improved clinical diagnostics; however, the complexity and cost hinder broad adoption. In this Letter, we introduce coherence function-encoded optical palpation (CFE-OP) using a novel optical profilometry technique that exploits the envelope of the coherence function rather than its peak position, which is typically used to retrieve depth information. CFE-OP utilizes a Fabry–Perot laser diode (bandwidth, 2.2 nm) and a single photodiode in a Michelson interferometer to detect the position along the coherence envelope as a function of path length. This technique greatly reduces complexity and cost in comparison to the OCT-based approach. We perform CFE-OP on phantom and excised human breast tissue, demonstrating comparable mechanical contrast to OCT-based optical palpation and the capability to distinguish stiff tumor from soft benign tissue.PostprintPeer reviewe

    Reference Breast Phantoms for Low-Cost Microwave Imaging

    Get PDF
    Microwave imaging provides an alternative method for breast cancer screening and the diagnosis of cerebrovascular accidents. Before a surgical operation, the performance of microwave imaging systems should be evaluated on anatomically detailed anthropomorphic phantoms. This paper puts forward the advances in the development of breast phantoms based on 3D printing structures filled with liquid solutions that mimic biological tissues in terms of complex permittivity in a wide microwave frequency band. In this paper; four different experimental scenarios were created, and measurements were performed, and although there are many vector network analyzers on the market, the miniVNA used in this study has been shown to have potential in many biomedical applications such as portable computer-based breast cancer detection studies. We especially investigated the reproducibility of a particular mixture and the ability of some mixes to mimic various breast tissues. Afterwards, the images similar to the experimentally created scenarios were obtained by implementing the inverse radon transform to the obtained data

    Focal Spot, Spring 1988

    Get PDF
    https://digitalcommons.wustl.edu/focal_spot_archives/1048/thumbnail.jp

    Microwave breast imaging using a dry setup

    Get PDF
    This article demonstrates for the first time, both numerically and experimentally, the feasibility of radar-based microwave imaging of anthropomorphic heterogeneously dense breasts in prone position, requiring no immersion liquid. The dry, contactless approach greatly simplifies the setup, favors patient comfort, and further avoids lengthy sanitation procedures after each exam. We use a radar-type technique with the antennas distributed in cylindrical configuration around the breast phantom. The reflectivity map is reconstructed using a wave-migration algorithm in the frequency domain. This article presents new developed strategies to cope with the challenges of a dry setup, namely increased skin artifact due to the concomitant absence of matching liquid and nonuniform breast shape. We propose an iterative and adaptive algorithm based on singular value decomposition that effectively removes the skin backscattering under the abovementioned conditions. It is compatible with automatic processing, and computationally fast. One of its inputs is the breast three-dimensional surface information, and its distance to the antennas, all obtained automatically from a proposed low-cost procedure based on a webcam. The imaging method is reasonably resilient to the presence of fibroglandular tissues, and to uncertainties of tissue permittivity. Another tackled challenge is the miniaturization of the antenna in air, which is achieved with an optimized balanced antipodal Vivaldi of the same size as counterparts used in dense immersion liquids. Finally, all the building blocks are combined to demonstrate experimentally the overall dry system performance, with very good detection of the tumor at three different positions in the breast, even in low-contrast scenarios.info:eu-repo/semantics/acceptedVersio

    3D UWB magnitude-combined tomographic imaging for biomedical applications. Algorithm validation

    Get PDF
    Biomedical microwave imaging is a topic of continuous research for its potential in different areas especially in breast cancer detection. In this paper, 3D UWB Magnitude-Combined tomographic algorithm is assessed for this recurrent application, but also for a more challenging one such as brain stroke detection. With the UWB Magnitude-Combined concept, the algorithm can take advantage of both the efficiency of Fourier Diffraction Theorem-based tomographic formulation and the robustness and image quality improvement provided by a multi-frequency combination.Peer ReviewedPostprint (published version

    Validation of a compact microwave imaging system for bone fracture detection

    Get PDF
    This work presents a systematic evaluation of the effectiveness of an air-operated microwave imaging (MWI) system for detection of arbitrarily oriented thin fractures in superficial bones, like the tibia. This includes the proposal of a new compact, portable setup where a single Vivaldi antenna performs a semi-cylindrical scan of the limb. The antenna is operated in monostatic radar mode, near the skin but without contact, thus ensuring hygiene and patient comfort during the exam. The image is reconstructed using a wave-migration algorithm in the frequency domain combined with an adaptative algorithm based on singular value decomposition to remove the skin artifact, dealing with non-uniform bone profile and tissue cover. The study investigates the system resolution, the robustness of the method to the uncertainty of the permittivity and thickness of the involved tested tissues, as well as the robustness to involuntary patient movement. The experimental validation was performed for the first time on an integral ex-vivo animal leg, with all tissues present, including skin and fur. It confirmed both the effectiveness of the method, and the feasibility of the setup.info:eu-repo/semantics/publishedVersio

    Evaluating a breast tumor monitoring vest with flexible UWB antennas and realistic phantoms:a proof-of-concept study

    Get PDF
    Abstract. The introduction provides an overview of the global significance of breast cancer as a health concern and the limitations of existing breast cancer screening methods. It introduces the concept of microwave-based breast cancer monitoring and highlights the promising findings from a previous research paper. The objective of the master thesis is presented, which is to develop and evaluate a self-monitoring vest equipped with UWB antennas and channel analysis to overcome the limitations of current screening methods and enable regular breast cancer monitoring from home. The "Background and Literature Review," provides a comprehensive overview of the relevant topics related to microwave techniques for breast cancer detection. It starts by discussing the anatomy of the female breast, highlighting the importance of understanding its structure for effective tumor detection. The section then delves into the microwave properties of the human breast, elucidating the interactions between microwaves and breast tissue. The basic principle of microwave channel analysis is explained, emphasizing its significance in detecting breast tumors. Furthermore, the advantages of microwave-based tumor detection methods are explored, showcasing their potential for improved breast cancer screening. Various microwave techniques used in breast cancer detection, including microwave tomography and radar-based UWB microwave imaging, are discussed, along with different self-monitoring vests integrated with UWB antennas. This section serves as a foundation for the subsequent chapters of the thesis, providing a comprehensive background and literature review to support the research and development of the practical self-monitoring vest for early detection of small-sized breast tumors. The "Preparation of Tissue Phantoms" section in the master’s thesis explores the comprehensive methodology for creating tissue phantoms that replicate the dielectric properties of various human tissues. While the section primarily focuses on fat tissue, it also acknowledges the existence of other phantom types. The outlined approach involves careful ingredient selection, formulation development, fabrication techniques, and stability evaluation for the creation of skin, muscle, fat, tumor, and gland tissue phantoms. By following these procedures, researchers can successfully produce tissue phantoms that closely mimic the properties of real human tissues. These phantoms serve as essential tools for investigating microwave-based applications in medical diagnostics and provide a reliable and versatile platform for further research in the field. The third section discusses the assembly of heterogeneous breast phantoms used for evaluating the performance of the tumor detection vest. The phantoms consisted of outer and inner molds, with the outer molds resembling the shape of a prone human breast. Two breast density types, representing very dense and less dense breasts, were used. For the dense breast phantoms, liquid fat material was solidified in the outer molds, and a glandular liquid was poured into the inner mold, with tumors inserted and covered with additional glandular liquid. For the less dense breast phantoms, fat liquid was solidified in the outer molds, and cylindrical glandular molds were inserted. A skin layer and muscle layer were added to complete the assembly, accurately simulating the composition and structure of a breast. This realistic breast phantom assembly allowed for accurate measurements and evaluation of the vest’s performance under different breast density conditions, contributing to breast imaging research and development. The "Monitoring Vest" section discusses the antennas used in the tumor detection vest and the design of two different vest versions. Antenna1 is a UWB monopole antenna with a flexible laminate substrate, while Antenna2 is a textile-based version of Antenna1. Antenna3 has a Kapton-based substrate and larger dimensions. The combination of these antennas ensures accurate tumor detection in various breast conditions. The section also highlights the measurement and comparison of the S11 parameter for the PCB antenna in free space and when placed on the skin, emphasizing the impact of the skin on antenna performance. The section concludes by describing the design of the vests, including the arrangement of pockets and the use of RF cables for connection. The careful design and implementation of the vests and antenna placement ensure accurate measurements and reliable performance evaluation. The results section of the study shows that the presence of tumors in breast tissue leads to a noticeable decrease in channel attenuation. The higher dielectric properties of tumors cause additional reflections and diffraction, affecting signal propagation within the breast. These changes in channel characteristics are influenced by factors such as tumor size, breast density, and antenna configuration. The study demonstrates the detectability of tumors and provides valuable insights for developing effective tumor detection systems in different breast tissue scenarios. In this master thesis, a prototype of a breast tumor monitoring vest utilizing UWB flexible antennas was developed and evaluated. The research demonstrated the effectiveness of the vest in detecting breast tumors, even as small as 1cm, by leveraging the distinct characteristics of radio channels among multiple on-body antennas embedded in the vest. Higher frequencies in the 7–8 GHz range showed improved resolution and contrast in relative permittivity, enhancing the accuracy of tumor detection. The development of tissue phantoms played a crucial role, enabling reliable experiments to mimic human tissues. Integration of advanced AI algorithms and 6G technology holds promise for enhancing diagnostic capabilities and revolutionizing healthcare. Overall, the breast tumor monitoring vest shows potential for widespread implementation in breast health checks, home monitoring, and wireless healthcare systems

    Determination of the breast cancer tumor diameter using a UWB microwave antenna system

    Get PDF
    This paper presents a novel ultra-wideband microwave antenna system to detect breast cancer and estimate tumor diameter. The system operates within the frequency range of 1 to 12 GHz and comprises a microstrip-fed monopole antenna that encircles the breast to identify the presence of tumors. The study demonstrates that a tumor within the breast can be detected by observing changes in the distribution of current density within the breast tissue, particularly in regions containing tumors of varying sizes. The research findings reveal that the system can identify breast tumors with the highest recorded current density of 188 A/m2 in cases with a tumor diameter of 30 mm, while the lowest recorded current density is 140 A/m2 for tumors with a diameter of 5 mm. Furthermore, the highest Specific Absorption Rate (SAR) value measured at the surface of the breast model is 0.2 W/kg. To determine the diameter of the tumors, the system collects and analyzes backscattered waves from a breast model. The investigation covers tumors with diameters ranging from 1 mm to 35 mm, and the received signals are recorded. In contrast to prior research, this study introduces an empirical model with a remarkable accuracy rate of 92.28% for characterizing the diameter of breast tumors based on the measurement analysis.</p
    • …
    corecore