109 research outputs found

    Methods and application areas of endoscopic optical coherence tomography

    Get PDF
    We review the current state of research in endoscopic optical coherence tomography (OCT). We first survey the range of available endoscopic optical imaging techniques. We then discuss the various OCT-based endoscopic methods that have thus far been developed. We compare the different endoscopic OCT methods in terms of their scan performance. Next, we examine the application range of endoscopic OCT methods. In particular, we look at the reported utility of the methods in digestive, intravascular, respiratory, urinary and reproductive systems. We highlight two additional applications—biopsy procedures and neurosurgery—where sufficiently compact OCT-based endoscopes can have significant clinical impacts

    Soft Robot-Assisted Minimally Invasive Surgery and Interventions: Advances and Outlook

    Get PDF
    Since the emergence of soft robotics around two decades ago, research interest in the field has escalated at a pace. It is fuelled by the industry's appreciation of the wide range of soft materials available that can be used to create highly dexterous robots with adaptability characteristics far beyond that which can be achieved with rigid component devices. The ability, inherent in soft robots, to compliantly adapt to the environment, has significantly sparked interest from the surgical robotics community. This article provides an in-depth overview of recent progress and outlines the remaining challenges in the development of soft robotics for minimally invasive surgery

    Robot-assistive minimally invasive surgery:trends and future directions

    Get PDF
    The evolution of medical technologies—such as surgical devices and imaging techniques—has transformed all aspects of surgery. A key area of development is robot-assisted minimally invasive surgery (MIS). This review paper provides an overview of the evolution of robotic MIS, from its infancy to our days, and envisioned future challenges. It provides an outlook of breakthrough surgical robotic platforms, their clinical applications, and their evolution over the years. It discusses how the integration of robotic, imaging, and sensing technologies has contributed to create novel surgical platforms that can provide the surgeons with enhanced dexterity, precision, and surgical navigation while reducing the invasiveness and efficacy of the intervention. Finally, this review provides an outlook on the future of robotic MIS discussing opportunities and challenges that the scientific community will have to address in the coming decade. We hope that this review serves to provide a quick and accessible way to introduce the readers to this exciting and fast-evolving area of research, and to inspire future research in this field

    Cable-driven parallel mechanisms for minimally invasive robotic surgery

    Get PDF
    Minimally invasive surgery (MIS) has revolutionised surgery by providing faster recovery times, less post-operative complications, improved cosmesis and reduced pain for the patient. Surgical robotics are used to further decrease the invasiveness of procedures, by using yet smaller and fewer incisions or using natural orifices as entry point. However, many robotic systems still suffer from technical challenges such as sufficient instrument dexterity and payloads, leading to limited adoption in clinical practice. Cable-driven parallel mechanisms (CDPMs) have unique properties, which can be used to overcome existing challenges in surgical robotics. These beneficial properties include high end-effector payloads, efficient force transmission and a large configurable instrument workspace. However, the use of CDPMs in MIS is largely unexplored. This research presents the first structured exploration of CDPMs for MIS and demonstrates the potential of this type of mechanism through the development of multiple prototypes: the ESD CYCLOPS, CDAQS, SIMPLE, neuroCYCLOPS and microCYCLOPS. One key challenge for MIS is the access method used to introduce CDPMs into the body. Three different access methods are presented by the prototypes. By focusing on the minimally invasive access method in which CDPMs are introduced into the body, the thesis provides a framework, which can be used by researchers, engineers and clinicians to identify future opportunities of CDPMs in MIS. Additionally, through user studies and pre-clinical studies, these prototypes demonstrate that this type of mechanism has several key advantages for surgical applications in which haptic feedback, safe automation or a high payload are required. These advantages, combined with the different access methods, demonstrate that CDPMs can have a key role in the advancement of MIS technology.Open Acces

    Methods and application areas of endoscopic optical coherence tomography

    Get PDF
    We review the current state of research in endoscopic optical coherence tomography (OCT). We first survey the range of available endoscopic optical imaging techniques. We then discuss the various OCT-based endoscopic methods that have thus far been developed. We compare the different endoscopic OCT methods in terms of their scan performance. Next, we examine the application range of endoscopic OCT methods. In particular, we look at the reported utility of the methods in digestive, intravascular, respiratory, urinary and reproductive systems. We highlight two additional applications—biopsy procedures and neurosurgery—where sufficiently compact OCT-based endoscopes can have significant clinical impacts

    OPTICAL NAVIGATION TECHNIQUES FOR MINIMALLY INVASIVE ROBOTIC SURGERIES

    Get PDF
    Minimally invasive surgery (MIS) involves small incisions in a patient's body, leading to reduced medical risk and shorter hospital stays compared to open surgeries. For these reasons, MIS has experienced increased demand across different types of surgery. MIS sometimes utilizes robotic instruments to complement human surgical manipulation to achieve higher precision than can be obtained with traditional surgeries. Modern surgical robots perform within a master-slave paradigm, in which a robotic slave replicates the control gestures emanating from a master tool manipulated by a human surgeon. Presently, certain human errors due to hand tremors or unintended acts are moderately compensated at the tool manipulation console. However, errors due to robotic vision and display to the surgeon are not equivalently addressed. Current vision capabilities within the master-slave robotic paradigm are supported by perceptual vision through a limited binocular view, which considerably impacts the hand-eye coordination of the surgeon and provides no quantitative geometric localization for robot targeting. These limitations lead to unexpected surgical outcomes, and longer operating times compared to open surgery. To improve vision capabilities within an endoscopic setting, we designed and built several image guided robotic systems, which obtained sub-millimeter accuracy. With this improved accuracy, we developed a corresponding surgical planning method for robotic automation. As a demonstration, we prototyped an autonomous electro-surgical robot that employed quantitative 3D structural reconstruction with near infrared registering and tissue classification methods to localize optimal targeting and suturing points for minimally invasive surgery. Results from validation of the cooperative control and registration between the vision system in a series of in vivo and in vitro experiments are presented and the potential enhancement to autonomous robotic minimally invasive surgery by utilizing our technique will be discussed
    • …