11 research outputs found

    Comparison of hyperbolic and constant width simultaneous confidence bands in multiple linear regression under MVCS criterion

    No full text
    A simultaneous confidence band provides useful information on the plausible range of the unknown regression model, and different confidence bands can often be constructed for the same regression model. For a simple regression line, Liu and Hayter (2007) propose use of the area of the confidence set corresponding to a confidence band as an optimality criterion in comparison of confidence bands; the smaller the area of the confidence set, the better the corresponding confidence band. This minimum area confidence set (MACS) criterion can begeneralized to a minimum volume confidence set (MVCS) criterion in the study of confidence bands for a multiple linear regression model. In this paper hyperbolic and constant width confidence bands for a multiple linear regression model over a particular ellipsoidal region of the predictor variables are compared under the MVCS criterion. It is observed that whether one band is better than the other depends on the magnitude of one particular angle that determines the size of the predictor variable region. When the angle and so the size of the predictor variable region is small, the constant width band is better than the hyperbolic band but only marginally. When the angle and so the size of the predictor variable region is large the hyperbolic band can be substantially better than the constant width band

    Comparison of hyperbolic and constant width simultaneous confidence bands in multiple linear regression under MVCS criterion

    Get PDF
    A simultaneous confidence band provides useful information on the plausible range of the unknown regression model, and different confidence bands can often be constructed for the same regression model. For a simple regression line, Liu and Hayter [W. Liu, A.J. Hayter, Minimum area confidence set optimality for confidence bands in simple linear regression, J. Amer. Statist. Assoc. 102 (477) (2007) pp. 181–190] proposed the use of the area of the confidence set corresponding to a confidence band as an optimality criterion in comparison of confidence bands; the smaller the area of the confidence set, the better the corresponding confidence band. This minimum area confidence set (MACS) criterion can be generalized to a minimum volume confidence set (MVCS) criterion in the study of confidence bands for a multiple linear regression model. In this paper hyperbolic and constant width confidence bands for a multiple linear regression model over a particular ellipsoidal region of the predictor variables are compared under the MVCS criterion. It is observed that whether one band is better than the other depends on the magnitude of one particular angle that determines the size of the predictor variable region. When the angle and hence the size of the predictor variable region is small, the constant width band is better than the hyperbolic band but only marginally. When the angle and hence the size of the predictor variable region is large the hyperbolic band can be substantially better than the constant width band

    Applications of EMG in Clinical and Sports Medicine

    Get PDF
    This second of two volumes on EMG (Electromyography) covers a wide range of clinical applications, as a complement to the methods discussed in volume 1. Topics range from gait and vibration analysis, through posture and falls prevention, to biofeedback in the treatment of neurologic swallowing impairment. The volume includes sections on back care, sports and performance medicine, gynecology/urology and orofacial function. Authors describe the procedures for their experimental studies with detailed and clear illustrations and references to the literature. The limitations of SEMG measures and methods for careful analysis are discussed. This broad compilation of articles discussing the use of EMG in both clinical and research applications demonstrates the utility of the method as a tool in a wide variety of disciplines and clinical fields

    Are ACE I/D and ACTN3 R577X polymorphisms associated with muscle function of young and older men, and frequent fallers?

    Get PDF
    Angiotensin Converting Enzyme (ACE) IID, and a actinin 3 (AC1N3) R577X polymorphisms have been linked to the strength and power performance of elite athletes and suggested to influence skeletal muscle function in the general popUlation. This research investigated the association of these two candidate gene polymorphisms with the muscle function of young and older men, and the distribution of these genotypes in frequent fallers compared to controls. Muscle function measurements of young and older men included isometric strength, absolute and relative isokinetic strength at high velocity (ratio of torque at 2400 ·s"; torque at 30°·s") and the time course of an evoked twitch. Additionally body composition was measured by skinfold thickness (young men) and DXA scanning (old men) to estimate fat-free mass, an index of muscularity, and fat mass. ACE and AC1N3 genotypes were determined from whole blood samples using polymerase chain reaction, and serum ACE activity using spectrophotometry. The gemtypes of frequent fallers referred to a Falls Clinic were compared to a control group of healthy men. ACE genotype was not associated with any measure of muscle function, including the time course of an evoked twitch or absolute and relative high velocity torque, or body composition in these populations (ANOVA, 0.1

    Investigation of the interaction between corticomuscular coherence, motor precision and perceived difficulty in wrist flexion and extension

    Get PDF
    Includes abstract.Includes bibliographical references.Recently, behavioural (motor precision) differences were reported between isometric wrist flexion and extension. Neurophysiological as well as clinical differences have also been reported between these antagonistic movements. Corticomuscular coherence (CMC), i.e. the frequency specific temporal coupling between the electroencephalogram (EEG) and electromyogram (EMG) recorded during isometric force production, reflects the functional connectivity between cortex and muscle. A single muscle (flexor digitorum superficialis) study suggests a positive correlation between 15-35 Hz (beta) CMC and motor precision of the muscle. Yet, no study has simultaneously compared CMC and motor precision between wrist flexion and extension. Task perceived difficulty, which is a perceptual variable, may influence both motor precision and CMC, but has not been studied yet. The main aim of the present study was to investigate the interaction between CMC, motor precision and perceived difficulty in isometric wrist flexion and extension tasks

    Are ACE I/D and ACTN3 R577X polymorphisms associated with the muscle function of young and older men, and frequent fallers?

    Get PDF
    Angiotensin Converting Enzyme (ACE) IID, and a actinin 3 (AC1N3) R577X polymorphisms have been linked to the strength and power performance of elite athletes and suggested to influence skeletal muscle function in the general popUlation. This research investigated the association of these two candidate gene polymorphisms with the muscle function of young and older men, and the distribution of these genotypes in frequent fallers compared to controls. Muscle function measurements of young and older men included isometric strength, absolute and relative isokinetic strength at high velocity (ratio of torque at 2400 ·s"; torque at 30°·s") and the time course of an evoked twitch. Additionally body composition was measured by skinfold thickness (young men) and DXA scanning (old men) to estimate fat-free mass, an index of muscularity, and fat mass. ACE and AC1N3 genotypes were determined from whole blood samples using polymerase chain reaction, and serum ACE activity using spectrophotometry. The gemtypes of frequent fallers referred to a Falls Clinic were compared to a control group of healthy men. ACE genotype was not associated with any measure of muscle function, including the time course of an evoked twitch or absolute and relative high velocity torque, or body composition in these populations (ANOVA, 0.12<P<0.97). Serum ACE activity appeared to be weakly associated with knee extensor (R = 0.19, P = 0.07) and elbow flexor (R = 0.20, P = 0.06) isometric strength in older men, and was negatively correlated with the relative torque at high velocity (R = -0.23, P = 0.03). AC1N3 genotype was associated with fat mass in older men (P = 0.04), but was not associated with any measure of muscle function or muscularity (KruskalWaIIis, 0.26<P<0.95). Finally there was no apparent difference in the distribution of ACE IID (r: = 0.54, P = 0.77) and AC1N3 RIX (r: = 0.76, P = 0.68) genotypes between frequent fallers and controls. Any influence of these individual polymorphisms seems unlikely to be of sufficient magnitude to produce genotype related differences in muscle function in young or older free living UK Caucasian men. Serum ACE activity may have a small association with the isometric and dynamic strength of older men. However, AC1N3 genotype was associated with increased fat mass in XX individuals, that suggests this polymorphism may have an association with the accumulation of body fat over the life span of older men.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Human Machine Interaction

    Get PDF
    In this book, the reader will find a set of papers divided into two sections. The first section presents different proposals focused on the human-machine interaction development process. The second section is devoted to different aspects of interaction, with a special emphasis on the physical interaction

    Applications of Power Electronics:Volume 1

    Get PDF
    corecore