681 research outputs found
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Light propagating in tissue attains a spectrum that varies with location due
to wavelength-dependent fluence attenuation by tissue optical properties, an
effect that causes spectral corruption. Predictions of the spectral variations
of light fluence in tissue are challenging since the spatial distribution of
optical properties in tissue cannot be resolved in high resolution or with high
accuracy by current methods. Spectral corruption has fundamentally limited the
quantification accuracy of optical and optoacoustic methods and impeded the
long sought-after goal of imaging blood oxygen saturation (sO2) deep in
tissues; a critical but still unattainable target for the assessment of
oxygenation in physiological processes and disease. We discover a new principle
underlying light fluence in tissues, which describes the wavelength dependence
of light fluence as an affine function of a few reference base spectra,
independently of the specific distribution of tissue optical properties. This
finding enables the introduction of a previously undocumented concept termed
eigenspectra Multispectral Optoacoustic Tomography (eMSOT) that can effectively
account for wavelength dependent light attenuation without explicit knowledge
of the tissue optical properties. We validate eMSOT in more than 2000
simulations and with phantom and animal measurements. We find that eMSOT can
quantitatively image tissue sO2 reaching in many occasions a better than
10-fold improved accuracy over conventional spectral optoacoustic methods.
Then, we show that eMSOT can spatially resolve sO2 in muscle and tumor;
revealing so far unattainable tissue physiology patterns. Last, we related
eMSOT readings to cancer hypoxia and found congruence between eMSOT tumor sO2
images and tissue perfusion and hypoxia maps obtained by correlative
histological analysis
Histopathological image analysis : a review
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches to radiological data. With the recent advent of whole slide digital scanners, tissue histopathology slides can now be digitized and stored in digital image form. Consequently, digitized tissue histopathology has now become amenable to the application of computerized image analysis and machine learning techniques. Analogous to the role of computer-assisted diagnosis (CAD) algorithms in medical imaging to complement the opinion of a radiologist, CAD algorithms have begun to be developed for disease detection, diagnosis, and prognosis prediction to complement the opinion of the pathologist. In this paper, we review the recent state of the art CAD technology for digitized histopathology. This paper also briefly describes the development and application of novel image analysis technology for a few specific histopathology related problems being pursued in the United States and Europe
Cell Interaction Analysis by Imaging Flow Cytometry
Many processes such as cell adhesion, tissue development, cellular communication, inflammation, tumor metastasis, and microbial infection require direct interactions between cells. Some cell-cell interactions are transient, as is the case of the contacts between cells ofthe immune system, the interactions of white blood cells to malignant cells or to sites oftissue inflammation. These events often entail structural alterations in the point of contact ofthe cells involved, and may involve the fusion, transfer or exchange of material between thecells; which occur in a scale that is suited for optical microscopy analysis. However, due toits low throughput nature, microscopy often suffers from acquisition bias and limitedstatistical power. Moreover, because the data is typically analyzed in a qualitative manner, itis difficult to obtain standardized results. Strong scientific conclusions demand objectivecollection of large amounts of relevant information that can be analyzed in a quantitative,standardized, and statistically robust manner. Flow cytometry overcomes these problemsbut reduces the rich information available via optical microscopy to a set of intensitymeasurements. By combining high speed automated image acquisition with quantitativeimage analysis, Multispectral Imaging Flow Cytometry (MIFC) provides all the elementsrequired for discriminating cells based on intensity and appearance in a standardized andstatistical manner. In recent years, the application of this technology for the analysis of cell-cell interaction has multiplied, in particular in the field of immunology, allowing theobservation and quantification of events in a way that could not be achieved before.Fil: Payés, Cristian. Consejo Nacional de Investigaciones CientÃficas y Técnicas. Oficina de Coordinación Administrativa Houssay; ArgentinaFil: RodrÃguez, José A.. No especifÃca;Fil: Friend, Sherree. No especifÃca;Fil: Helguera, Gustavo Fernando. Consejo Nacional de Investigaciones CientÃficas y Técnicas. Oficina de Coordinación Administrativa Houssay; Argentin
Recommended from our members
Oxygen-Enhanced and Dynamic Contrast-Enhanced Optoacoustic Tomography Provide Surrogate Biomarkers of Tumor Vascular Function, Hypoxia, and Necrosis.
Measuring the functional status of tumor vasculature, including blood flow fluctuations and changes in oxygenation, is important in cancer staging and therapy monitoring. Current clinically approved imaging modalities suffer long procedure times and limited spatiotemporal resolution. Optoacoustic tomography (OT) is an emerging clinical imaging modality that may overcome these challenges. By acquiring data at multiple wavelengths, OT can interrogate hemoglobin concentration and oxygenation directly and resolve contributions from injected contrast agents. In this study, we tested whether two dynamic OT techniques, oxygen-enhanced (OE) and dynamic contrast-enhanced (DCE)-OT, could provide surrogate biomarkers of tumor vascular function, hypoxia, and necrosis. We found that vascular maturity led to changes in vascular function that affected tumor perfusion, modulating the DCE-OT signal. Perfusion in turn regulated oxygen availability, driving the OE-OT signal. In particular, we demonstrate for the first time a strong per-tumor and spatial correlation between imaging biomarkers derived from these in vivo techniques and tumor hypoxia quantified ex vivo Our findings indicate that OT may offer a significant advantage for localized imaging of tumor response to vascular-targeted therapies when compared with existing clinical DCE methods.Significance: Imaging biomarkers derived from optoacoustic tomography can be used as surrogate measures of tumor perfusion and hypoxia, potentially yielding rapid, multiparametric, and noninvasive cancer staging and therapeutic response monitoring in the clinic.Graphical Abstract: http://cancerres.aacrjournals.org/content/canres/78/20/5980/F1.large.jpg Cancer Res; 78(20); 5980-91. ©2018 AACR
Imaging White Blood Cells using a Snapshot Hyper-Spectral Imaging System
Automated white blood cell (WBC) counting systems process an extracted whole blood sample and provide a cell count. A step that would not be ideal for onsite screening of individuals in triage or at a security gate. Snapshot Hyper-Spectral imaging systems are capable of capturing several spectral bands simultaneously, offering co-registered images of a target. With appropriate optics, these systems are potentially able to image blood cells in vivo as they flow through a vessel, eliminating the need for a blood draw and sample staining. Our group has evaluated the capability of a commercial Snapshot Hyper-Spectral imaging system, specifically the Arrow system from Rebellion Photonics, in differentiating between white and red blood cells on unstained and sealed blood smear slides. We evaluated the imaging capabilities of this hyperspectral camera as a platform to build an automated blood cell counting system. Hyperspectral data consisting of 25, 443x313 hyperspectral bands with ~3nm spacing were captured over the range of 419 to 494nm. Open-source hyperspectral datacube analysis tools, used primarily in Geographic Information Systems (GIS) applications, indicate that white blood cells\u27 features are most prominent in the 428-442nm band for blood samples viewed under 20x and 50x magnification over a varying range of illumination intensities. The system has shown to successfully segment blood cells based on their spectral-spatial information. These images could potentially be used in subsequent automated white blood cell segmentation and counting algorithms for performing in vivo white blood cell counting
Computer vision for microscopy diagnosis of malaria
This paper reviews computer vision and image analysis studies aiming at automated diagnosis or screening of malaria infection in microscope images of thin blood film smears. Existing works interpret the diagnosis problem differently or propose partial solutions to the problem. A critique of these works is furnished. In addition, a general pattern recognition framework to perform diagnosis, which includes image acquisition, pre-processing, segmentation, and pattern classification components, is described. The open problems are addressed and a perspective of the future work for realization of automated microscopy diagnosis of malaria is provided
Alteration in Fluidity of Cell Plasma Membrane in Huntington Disease Revealed by Spectral Phasor Analysis.
Huntington disease (HD) is a late-onset genetic neurodegenerative disorder caused by expansion of cytosine-adenine-guanine (CAG) trinucleotide in the exon 1 of the gene encoding the polyglutamine (polyQ). It has been shown that protein degradation and lipid metabolism is altered in HD. In many neurodegenerative disorders, impaired lipid homeostasis is one of the early events in the disease onset. Yet, little is known about how mutant huntingtin may affect phospholipids membrane fluidity. Here, we investigated how membrane fluidity in the living cells (differentiated PC12 and HEK293 cell lines) are affected using a hyperspectral imaging of widely used probes, LAURDAN. Using phasor approach, we characterized the fluorescence of LAURDAN that is sensitive to the polarity of the immediate environment. LAURDAN is affected by the physical order of phospholipids (lipid order) and reports the membrane fluidity. We also validated our results using a different fluorescent membrane probe, Nile Red (NR). The plasma membrane in the cells expressing expanded polyQ shows a shift toward increased membrane fluidity revealed by both LAURDAN and NR spectral phasors. This finding brings a new perspective in the understanding of the early stages of HD that can be used as a target for drug screening
- …