3 research outputs found

    Anomaly detection of consumption in Hotel Units: A case study comparing isolation forest and variational autoencoder algorithms

    Get PDF
    Buildings are responsible for a high percentage of global energy consumption, and thus, the improvement of their efficiency can positively impact not only the costs to the companies they house, but also at a global level. One way to reduce that impact is to constantly monitor the consumption levels of these buildings and to quickly act when unjustified levels are detected. Currently, a variety of sensor networks can be deployed to constantly monitor many variables associated with these buildings, including distinct types of meters, air temperature, solar radiation, etc. However, as consumption is highly dependent on occupancy and environmental variables, the identification of anomalous consumption levels is a challenging task. This study focuses on the implementation of an intelligent system, capable of performing the early detection of anomalous sequences of values in consumption time series applied to distinct hotel unit meters. The development of the system was performed in several steps, which resulted in the implementation of several modules. An initial (i) Exploratory Data Analysis (EDA) phase was made to analyze the data, including the consumption datasets of electricity, water, and gas, obtained over several years. The results of the EDA were used to implement a (ii) data correction module, capable of dealing with the transmission losses and erroneous values identified during the EDA’s phase. Then, a (iii) comparative study was performed between a machine learning (ML) algorithm and a deep learning (DL) one, respectively, the isolation forest (IF) and a variational autoencoder (VAE). The study was made, taking into consideration a (iv) proposed performance metric for anomaly detection algorithms in unsupervised time series, also considering computational requirements and adaptability to different types of data. (v) The results show that the IF algorithm is a better solution for the presented problem, since it is easily adaptable to different sources of data, to different combinations of features, and has lower computational complexity. This allows its deployment without major computational requirements, high knowledge, and data history, whilst also being less prone to problems with missing data. As a global outcome, an architecture of a platform is proposed that encompasses the mentioned modules. The platform represents a running system, performing continuous detection and quickly alerting hotel managers about possible anomalous consumption levels, allowing them to take more timely measures to investigate and solve the associated causes.info:eu-repo/semantics/publishedVersio

    Architecture for Enabling Edge Inference via Model Transfer from Cloud Domain in a Kubernetes Environment

    Get PDF
    The current approaches for energy consumption optimisation in buildings are mainly reactive or focus on scheduling of daily/weekly operation modes in heating. Machine Learning (ML)-based advanced control methods have been demonstrated to improve energy efficiency when compared to these traditional methods. However, placing of ML-based models close to the buildings is not straightforward. Firstly, edge-devices typically have lower capabilities in terms of processing power, memory, and storage, which may limit execution of ML-based inference at the edge. Secondly, associated building information should be kept private. Thirdly, network access may be limited for serving a large number of edge devices. The contribution of this paper is an architecture, which enables training of ML-based models for energy consumption prediction in private cloud domain, and transfer of the models to edge nodes for prediction in Kubernetes environment. Additionally, predictors at the edge nodes can be automatically updated without interrupting operation. Performance results with sensor-based devices (Raspberry Pi 4 and Jetson Nano) indicated that a satisfactory prediction latency (~7–9 s) can be achieved within the research context. However, model switching led to an increase in prediction latency (~9–13 s). Partial evaluation of a Reference Architecture for edge computing systems, which was used as a starting point for architecture design, may be considered as an additional contribution of the paper

    Artificial Intelligence based Anomaly Detection of Energy Consumption in Buildings: A Review, Current Trends and New Perspectives

    Get PDF
    Enormous amounts of data are being produced everyday by sub-meters and smart sensors installed in residential buildings. If leveraged properly, that data could assist end-users, energy producers and utility companies in detecting anomalous power consumption and understanding the causes of each anomaly. Therefore, anomaly detection could stop a minor problem becoming overwhelming. Moreover, it will aid in better decision-making to reduce wasted energy and promote sustainable and energy efficient behavior. In this regard, this paper is an in-depth review of existing anomaly detection frameworks for building energy consumption based on artificial intelligence. Specifically, an extensive survey is presented, in which a comprehensive taxonomy is introduced to classify existing algorithms based on different modules and parameters adopted, such as machine learning algorithms, feature extraction approaches, anomaly detection levels, computing platforms and application scenarios. To the best of the authors' knowledge, this is the first review article that discusses anomaly detection in building energy consumption. Moving forward, important findings along with domain-specific problems, difficulties and challenges that remain unresolved are thoroughly discussed, including the absence of: (i) precise definitions of anomalous power consumption, (ii) annotated datasets, (iii) unified metrics to assess the performance of existing solutions, (iv) platforms for reproducibility and (v) privacy-preservation. Following, insights about current research trends are discussed to widen the applications and effectiveness of the anomaly detection technology before deriving future directions attracting significant attention. This article serves as a comprehensive reference to understand the current technological progress in anomaly detection of energy consumption based on artificial intelligence.Comment: 11 Figures, 3 Table
    corecore