10 research outputs found

    DeepASL: Enabling Ubiquitous and Non-Intrusive Word and Sentence-Level Sign Language Translation

    Full text link
    There is an undeniable communication barrier between deaf people and people with normal hearing ability. Although innovations in sign language translation technology aim to tear down this communication barrier, the majority of existing sign language translation systems are either intrusive or constrained by resolution or ambient lighting conditions. Moreover, these existing systems can only perform single-sign ASL translation rather than sentence-level translation, making them much less useful in daily-life communication scenarios. In this work, we fill this critical gap by presenting DeepASL, a transformative deep learning-based sign language translation technology that enables ubiquitous and non-intrusive American Sign Language (ASL) translation at both word and sentence levels. DeepASL uses infrared light as its sensing mechanism to non-intrusively capture the ASL signs. It incorporates a novel hierarchical bidirectional deep recurrent neural network (HB-RNN) and a probabilistic framework based on Connectionist Temporal Classification (CTC) for word-level and sentence-level ASL translation respectively. To evaluate its performance, we have collected 7,306 samples from 11 participants, covering 56 commonly used ASL words and 100 ASL sentences. DeepASL achieves an average 94.5% word-level translation accuracy and an average 8.2% word error rate on translating unseen ASL sentences. Given its promising performance, we believe DeepASL represents a significant step towards breaking the communication barrier between deaf people and hearing majority, and thus has the significant potential to fundamentally change deaf people's lives

    Incorporating Modular Arrangement of Predetermined Time Standard with a Wearable Sensing Glove

    Get PDF
    “Performance” – a common watchword in the present age, and that which is optimized through the most functional methodology of investigating the work procedure. This encompassed the auditing, updating of the tasks, while at the same time, applied automation and mechanization. The Modular Arrangement of Predetermined Time Standard (MODAPTS) is a useful application of a work measurement technique that allow a greater variety of work for manufacturing, engineering, and administrative service activities to be measured quickly with ease and accuracy. The MODAPTS, however, made it extremely difficult for engineers to use because it required an ample amount of time to analyze and code the raw data. A new design was proposed to help resolve the conventional system\u27s inadequacy because in MODAPTS, each task cycle of a minute required about 2 hours to calculate and document, and also, the judgment of the analysts varied for the same task. This study aimed to reduce the time taken for the traditional MODAPTS documentation usually took and produced unified results by integrating MODAPTS with a Sensing Wearable Glove while maintaining the same performance. The objective was to introduce an easy, cost-effective solution, and to compare the accuracy of coding between manual and automated calculated MODAPTS while maintaining consistent performance. This study discusses the glove and accompanying software design that detected movements using flex sensors, gyroscopes, microcontrollers, and pressure sensors. These movements were translated into analog data used to create MODAPTS codes as an output, which then sent the data wirelessly using the Bluetooth module. The device designed in this study is capable of sensing gestures for various operations, and the traditional method was compared to the proposed method. This was in turn, validated using the two-way ANOVA analysis. It was observed that the sensor-based glove provided efficient and reliable results, just like the traditional method results while maintaining the same performance

    Robust Signal Processing Techniques for Wearable Inertial Measurement Unit (IMU) Sensors

    Get PDF
    Activity and gesture recognition using wearable motion sensors, also known as inertial measurement units (IMUs), provides important context for many ubiquitous sensing applications including healthcare monitoring, human computer interface and context-aware smart homes and offices. Such systems are gaining popularity due to their minimal cost and ability to provide sensing functionality at any time and place. However, several factors can affect the system performance such as sensor location and orientation displacement, activity and gesture inconsistency, movement speed variation and lack of tiny motion information. This research is focused on developing signal processing solutions to ensure the system robustness with respect to these factors. Firstly, for existing systems which have already been designed to work with certain sensor orientation/location, this research proposes opportunistic calibration algorithms leveraging camera information from the environment to ensure the system performs correctly despite location or orientation displacement of the sensors. The calibration algorithms do not require extra effort from the users and the calibration is done seamlessly when the users present in front of an environmental camera and perform arbitrary movements. Secondly, an orientation independent and speed independent approach is proposed and studied by exploring a novel orientation independent feature set and by intelligently selecting only the relevant and consistent portions of various activities and gestures. Thirdly, in order to address the challenge that the IMU is not able capture tiny motion which is important to some applications, a sensor fusion framework is proposed to fuse the complementary sensor modality in order to enhance the system performance and robustness. For example, American Sign Language has a large vocabulary of signs and a recognition system solely based on IMU sensors would not perform very well. In order to demonstrate the feasibility of sensor fusion techniques, a robust real-time American Sign Language recognition approach is developed using wrist worn IMU and surface electromyography (EMG) sensors

    Robust Signal Processing Techniques for Wearable Inertial Measurement Unit (IMU) Sensors

    Get PDF
    Activity and gesture recognition using wearable motion sensors, also known as inertial measurement units (IMUs), provides important context for many ubiquitous sensing applications including healthcare monitoring, human computer interface and context-aware smart homes and offices. Such systems are gaining popularity due to their minimal cost and ability to provide sensing functionality at any time and place. However, several factors can affect the system performance such as sensor location and orientation displacement, activity and gesture inconsistency, movement speed variation and lack of tiny motion information. This research is focused on developing signal processing solutions to ensure the system robustness with respect to these factors. Firstly, for existing systems which have already been designed to work with certain sensor orientation/location, this research proposes opportunistic calibration algorithms leveraging camera information from the environment to ensure the system performs correctly despite location or orientation displacement of the sensors. The calibration algorithms do not require extra effort from the users and the calibration is done seamlessly when the users present in front of an environmental camera and perform arbitrary movements. Secondly, an orientation independent and speed independent approach is proposed and studied by exploring a novel orientation independent feature set and by intelligently selecting only the relevant and consistent portions of various activities and gestures. Thirdly, in order to address the challenge that the IMU is not able capture tiny motion which is important to some applications, a sensor fusion framework is proposed to fuse the complementary sensor modality in order to enhance the system performance and robustness. For example, American Sign Language has a large vocabulary of signs and a recognition system solely based on IMU sensors would not perform very well. In order to demonstrate the feasibility of sensor fusion techniques, a robust real-time American Sign Language recognition approach is developed using wrist worn IMU and surface electromyography (EMG) sensors
    corecore