2,630 research outputs found
Recommended from our members
Automatic Segmentation of Coronary Arteries in CT Imaging in the Presence of Kissing Vessel Artifacts
In this paper, we present a novel two-step algorithm for segmentation of coronary arteries in computed tomography images based on the framework of active contours. In the proposed method, both global and local intensity information is utilized in the energy calculation. The global term is defined as a normalized cumulative distribution function, which contributes to the overall active contour energy in an adaptive fashion based on image histograms, to deform the active contour away from local stationary points. Possible outliers, such as kissing vessel artifacts, are removed in the postprocessing stage by a slice-by-slice correction scheme based on multiregion competition, where both arteries and kissing vessels are identified and tracked through the slices. The efficiency and the accuracy of the proposed technique are demonstrated on both synthetic and real datasets. The results on clinical datasets show that the method is able to extract the major branches of arteries with an average distance of 0.73 voxels to the manually delineated ground truth data. In the presence of kissing vessel artifacts, the outer surface of the entire coronary tree, extracted by the proposed algorithm, is smooth and contains fewer erroneous regions, originating in kissing vessel artifacts, as compared to the initial segmentation
Computer Vision and Medical Image Processing: a brief survey of application areas
Every day is greater the number of images obtained to characterize the anatomy and functions of the human body, because of this the automation of the medical image processing has become a practice to improve the diagnosis and treatment of certain diseases. In this study the main areas of application of computer vision to the digital processing of medical images are reviewed. It begins with the selection of the three edges with more publications available in Springer, ScienceDirect, Wiley, and IEEE which are: segmentation of organs and lesions, feature extraction in optical images and labelling machine on x-ray images. Over them, latest algorithms, techniques and methods for medical imaging processing are analyzed exposing its main characteristics and ways of use.Sociedad Argentina de Informática e Investigación Operativa (SADIO
Computer Vision and Medical Image Processing: a brief survey of application areas
Every day is greater the number of images obtained to characterize the anatomy and functions of the human body, because of this the automation of the medical image processing has become a practice to improve the diagnosis and treatment of certain diseases. In this study the main areas of application of computer vision to the digital processing of medical images are reviewed. It begins with the selection of the three edges with more publications available in Springer, ScienceDirect, Wiley, and IEEE which are: segmentation of organs and lesions, feature extraction in optical images and labelling machine on x-ray images. Over them, latest algorithms, techniques and methods for medical imaging processing are analyzed exposing its main characteristics and ways of use.Sociedad Argentina de Informática e Investigación Operativa (SADIO
Combining Shape and Learning for Medical Image Analysis
Automatic methods with the ability to make accurate, fast and robust assessments of medical images are highly requested in medical research and clinical care. Excellent automatic algorithms are characterized by speed, allowing for scalability, and an accuracy comparable to an expert radiologist. They should produce morphologically and physiologically plausible results while generalizing well to unseen and rare anatomies. Still, there are few, if any, applications where today\u27s automatic methods succeed to meet these requirements.\ua0The focus of this thesis is two tasks essential for enabling automatic medical image assessment, medical image segmentation and medical image registration. Medical image registration, i.e. aligning two separate medical images, is used as an important sub-routine in many image analysis tools as well as in image fusion, disease progress tracking and population statistics. Medical image segmentation, i.e. delineating anatomically or physiologically meaningful boundaries, is used for both diagnostic and visualization purposes in a wide range of applications, e.g. in computer-aided diagnosis and surgery.The thesis comprises five papers addressing medical image registration and/or segmentation for a diverse set of applications and modalities, i.e. pericardium segmentation in cardiac CTA, brain region parcellation in MRI, multi-organ segmentation in CT, heart ventricle segmentation in cardiac ultrasound and tau PET registration. The five papers propose competitive registration and segmentation methods enabled by machine learning techniques, e.g. random decision forests and convolutional neural networks, as well as by shape modelling, e.g. multi-atlas segmentation and conditional random fields
Recommended from our members
Blood Vessel Segmentation and shape analysis for quantification of Coronary Artery Stenosis in CT Angiography
This thesis presents an automated framework for quantitative vascular shape analysis of the coronary arteries, which constitutes an important and fundamental component of an automated image-based diagnostic system. Firstly, an automated vessel segmentation algorithm is developed to extract the coronary arteries based on the framework of active contours. Both global and local intensity statistics are utilised in the energy functional calculation, which allows for dealing with non-uniform brightness conditions, while evolving the contour towards to the desired boundaries without being trapped in local minima. To suppress kissing vessel artifacts, a slice-by-slice correction scheme, based on multiple regions competition, is proposed to identify and track the kissing vessels throughout the transaxial images of the CTA data. Based on the resulting segmentation, we then present a dedicated algorithm to estimate the geometric parameters of the extracted arteries, with focus on vessel bifurcations. In particular, the centreline and associated reference surface of the coronary arteries, in the vicinity of arterial bifurcations, are determined by registering an elliptical cross sectional tube to the desired constituent branch. The registration problem is solved by a hybrid optimisation method, combining local greedy search and dynamic programming, which ensures the global optimality of the solution and permits the incorporation of any hard constraints posed to the tube model within a natural and direct framework. In contrast with conventional volume domain methods, this technique works directly on the mesh domain, thus alleviating the need for image upsampling. The performance of the proposed framework, in terms of efficiency and accuracy, is demonstrated on both synthetic and clinical image data. Experimental results have shown that our techniques are capable of extracting the major branches of the coronary arteries and estimating the related geometric parameters (i.e., the centreline and the reference surface) with a high degree of agreement to those obtained through manual delineation. Particularly, all of the major branches of coronary arteries are successfully detected by the proposed technique, with a voxel-wise error at 0.73 voxels to the manually delineated ground truth data. Through the application of the slice-by-slice correction scheme, the false positive metric, for those coronary segments affected by kissing vessel artifacts, reduces from 294% to 22.5%. In terms of the capability of the presented framework in defining the location of centrelines across vessel bifurcations, the mean square errors (MSE) of the resulting centreline, with respect to the ground truth data, is reduced by an average of 62.3%, when compared with initial estimation obtained using a topological thinning based algorithm
Flow pattern analysis for magnetic resonance velocity imaging
Blood flow in the heart is highly complex. Although blood flow patterns have been investigated by both computational modelling and invasive/non-invasive imaging techniques, their evolution and intrinsic connection with cardiovascular disease has yet to be explored. Magnetic resonance (MR) velocity imaging provides a comprehensive distribution of multi-directional in vivo flow distribution so that detailed quantitative analysis of flow patterns is now possible. However, direct visualisation or quantification of vector fields is of little clinical use, especially for inter-subject or serial comparison of changes in flow patterns due to the progression of the disease or in response to therapeutic measures. In order to achieve a comprehensive and integrated description of flow in health and disease, it is necessary to characterise and model both normal and abnormal flows and their effects. To accommodate the diversity of flow patterns in relation to morphological and functional changes, we have described in this thesis an approach of detecting salient topological features prior to analytical assessment of dynamical indices of the flow patterns. To improve the accuracy of quantitative analysis of the evolution of topological flow features, it is essential to restore the original flow fields so that critical points associated with salient flow features can be more reliably detected. We propose a novel framework for the restoration, abstraction, extraction and tracking of flow features such that their dynamic indices can be accurately tracked and quantified. The restoration method is formulated as a constrained optimisation problem to remove the effects of noise and to improve the consistency of the MR velocity data. A computational scheme is derived from the First Order Lagrangian Method for solving the optimisation problem. After restoration, flow abstraction is applied to partition the entire flow field into clusters, each of which is represented by a local linear expansion of its velocity components. This process not only greatly reduces the amount of data required to encode the velocity distribution but also permits an analytical representation of the flow field from which critical points associated with salient flow features can be accurately extracted. After the critical points are extracted, phase portrait theory can be applied to separate them into attracting/repelling focuses, attracting/repelling nodes, planar vortex, or saddle. In this thesis, we have focused on vortical flow features formed in diastole. To track the movement of the vortices within a cardiac cycle, a tracking algorithm based on relaxation labelling is employed. The constraints and parameters used in the tracking algorithm are designed using the characteristics of the vortices. The proposed framework is validated with both simulated and in vivo data acquired from patients with sequential MR examination following myocardial infarction. The main contribution of the thesis is in the new vector field restoration and flow feature abstraction method proposed. They allow the accurate tracking and quantification of dynamic indices associated with salient features so that inter- and intra-subject comparisons can be more easily made. This provides further insight into the evolution of blood flow patterns and permits the establishment of links between blood flow patterns and localised genesis and progression of cardiovascular disease.Open acces
Coronary Artery Segmentation and Motion Modelling
Conventional coronary artery bypass surgery requires invasive sternotomy and the
use of a cardiopulmonary bypass, which leads to long recovery period and has high
infectious potential. Totally endoscopic coronary artery bypass (TECAB) surgery
based on image guided robotic surgical approaches have been developed to allow the
clinicians to conduct the bypass surgery off-pump with only three pin holes incisions
in the chest cavity, through which two robotic arms and one stereo endoscopic camera
are inserted. However, the restricted field of view of the stereo endoscopic images leads
to possible vessel misidentification and coronary artery mis-localization. This results
in 20-30% conversion rates from TECAB surgery to the conventional approach.
We have constructed patient-specific 3D + time coronary artery and left ventricle
motion models from preoperative 4D Computed Tomography Angiography (CTA)
scans. Through temporally and spatially aligning this model with the intraoperative
endoscopic views of the patient's beating heart, this work assists the surgeon to identify
and locate the correct coronaries during the TECAB precedures. Thus this work has
the prospect of reducing the conversion rate from TECAB to conventional coronary
bypass procedures.
This thesis mainly focus on designing segmentation and motion tracking methods
of the coronary arteries in order to build pre-operative patient-specific motion models.
Various vessel centreline extraction and lumen segmentation algorithms are presented,
including intensity based approaches, geometric model matching method and
morphology-based method. A probabilistic atlas of the coronary arteries is formed
from a group of subjects to facilitate the vascular segmentation and registration procedures.
Non-rigid registration framework based on a free-form deformation model
and multi-level multi-channel large deformation diffeomorphic metric mapping are
proposed to track the coronary motion. The methods are applied to 4D CTA images
acquired from various groups of patients and quantitatively evaluated
A computationally efficient approach to segmentation of the aorta and coronary arteries using deep learning
Early detection and diagnosis of coronary artery disease could reduce the risk of developing a heart attack. The coronary arteries are optimally visualised using computed tomography coronary angiography (CTCA) imaging. These images are reviewed by specialist radiologists who evaluate the coronary arteries for potential narrowing. A lack of radiologists in the UK is a constraint to timely diagnosis of coronary artery disease, particularly in the acute accident and emergency department setting. The development of automated methods by which coronary artery narrowing can be identified rapidly and accurately are therefore timely. Such complex computer based tools also need to be sufficiently computationally efficient that they can run on servers typically found in hospital settings, where graphical processing units for example are unavailable. We propose a fully automatic two-dimensional Unet model to segment the aorta and coronary arteries on CTCA images. Two models are trained to segment two regions of interest, (1) the aorta and the coronary arteries or (2) the coronary arteries alone. Our method achieves 91.20% and 88.80% dice similarity coefficient accuracy on regions of interest 1 and 2 respectively. Compared with a semi-automatic segmentation method, our model performs better when segmenting the coronary arteries alone. The performance of the proposed method is comparable to existing published two-dimensional or three-dimensional deep learning models. Importantly, the algorithmic and graphical processing unit memory efficiencies are maintained such that the model can be deployed without requiring graphical processing units, and therefore can be used in a hospital setting
Neural network-based coronary dominance classification of RCA angiograms
Background. Cardiac dominance classification is essential for SYNTAX score
estimation, which is a tool used to determine the complexity of coronary artery
disease and guide patient selection toward optimal revascularization strategy.
Objectives. Cardiac dominance classification algorithm based on the analysis of
right coronary artery (RCA) angiograms using neural network Method. We employed
convolutional neural network ConvNext and Swin transformer for 2D image
(frames) classification, along with a majority vote for cardio angiographic
view classification. An auxiliary network was also used to detect irrelevant
images which were then excluded from the data set. Our data set consisted of
828 angiographic studies, 192 of them being patients with left dominance.
Results. 5-fold cross validation gave the following dominance classification
metrics (p=95%): macro recall=93.1%, accuracy=93.5%, macro F1=89.2%. The most
common case in which the model regularly failed was RCA occlusion, as it
requires utilization of LCA information. Another cause for false prediction is
a small diameter combined with poor quality cardio angiographic view. In such
cases, cardiac dominance classification can be complex and may require
discussion among specialists to reach an accurate conclusion. Conclusion. The
use of machine learning approaches to classify cardiac dominance based on RCA
alone has been shown to be successful with satisfactory accuracy. However, for
higher accuracy, it is necessary to utilize LCA information in the case of an
occluded RCA and detect cases where there is high uncertainty
- …