    Cross-Calibration of AQUA-MODIS and NPP-VIIRS Reflective Solar Bands for a Seamless Record of CERES Cloud and Flux Properties

    Get PDF
    The CERES measured shortwave and longwave fluxes rely on the cloud properties derived using the coincident observations from the accompanying high-resolution MODIS and VIIRS imagers. The calibration consistency is required between MODIS and VIIRS radiances to ensure that the CERES provided cloud property retrievals are temporally consistent. This paper presents multiple approaches of cross-calibrating the spectrally comparable reflective solar bands (RSB) of Aqua-MODIS and NPP- VIIRS, and estimates the radiometric biases for individual band pair. The inter-comparison is performed between the Aqua-MODIS collection 6.1 level 1B and NPP-VIIRS Land PEATE V1 datasets. Radiometric biases up to 3% were estimated bet een the MODIS and VIIRS radiances for visible bands

    Initial Stability Assessment of S-NPP VIIRS Reflective Solar Band Calibration Using Invariant Desert and Deep Convective Cloud Targets

    Get PDF
    The latest CERES FM-5 instrument launched onboard the S-NPP spacecraft will use the VIIRS visible radiances from the NASA Land Product Evaluation and Analysis Tool Elements (PEATE) product for retrieving the cloud properties associated with its TOA flux measurement. In order for CERES to provide climate quality TOA flux datasets, the retrieved cloud properties must be consistent throughout the record, which is dependent on the calibration stability of the VIIRS imager. This paper assesses the NASA calibration stability of the VIIRS reflective solar bands using the Libya-4 desert and deep convective clouds (DCC). The invariant targets are first evaluated for temporal natural variability. It is found for visible (VIS) bands that DCC targets have half of the variability of Libya-4. For the shortwave infrared (SWIR) bands, the desert has less variability. The brief VIIRS record and target variability inhibits high confidence in identifying any trends that are less than 0.6yr for most VIS bands, and 2.5yr for SWIR bands. None of the observed invariant target reflective solar band trends exceeded these trend thresholds. Initial assessment results show that the VIIRS data have been consistently calibrated and that the VIIRS instrument stability is similar to or better than the MODIS instrument

    Enhancements to the Open Access Spectral Band Adjustment Factor Online Calculation Tool for Visible Channels

    Get PDF
    With close to 40 years of satellite observations, from which, cloud, land-use, and aerosol parameters can be measured, inter-consistent calibrations are needed to normalize retrievals across satellite records. Various visible-sensor inter-calibration techniques have been developed that utilize radiometrically stable Earth targets, e.g., deep convective clouds and desert/polar ice pseudo-invariant calibration sites. Other equally effective, direct techniques for intercalibration between satellite imagers are simultaneous nadir overpass comparisons and ray-matched radiance pairs. Combining independent calibration results from such varied techniques yields robust calibration coefficients, and is a form of self-validation. One potential source of significant error when cross-calibrating satellite sensors, however, are the often small but substantial spectral discrepancies between comparable bands, which must be accounted for. As such, visible calibration methods rely on a Spectral Band Adjustment Factor (SBAF) to account for the spectral-response function- induced radiance differences between analogous imagers. The SBAF is unique to each calibration method as it is a function of the Earth-reflected spectra. In recent years, NASA Langley pioneered the use of SCIAMACHY-, GOME-2-, and Hyperion-retrieved Earth spectra to compute SBAFs. By carefully selecting hyperspectral footprints that best represent the conditions inherent to an inter-calibration technique, the uncertainty in the SBAF is greatly reduced. NASA Langley initially provided the Global Space-based Inter-calibration System processing and research centers with online SBAF tools, with which users select conditions to best match their calibration criteria. This article highlights expanded SBAF tool capabilities for visible wavelengths, with emphasis on the use of the spectral range filtering for the purpose of separating scene conditions for the channel that the SBAF is needed based on the reflectance values of other bands. In other words, spectral filtering will enable better scene-type selection for bands where scene determination is difficult without information from other channels, which should prove valuable to users in the calibration community

    Results from the Deep-Convective Clouds (DCC) Based Response Versus Scan-Angle (RVS) Characterization for the MODIS Reflective Solar Bands

    Get PDF
    The Terra and Aqua MODIS scan mirror reflectance is a function of the angle of incidence (AOI) and was characterized prior to launch by the instrument vendor. The relative change of the prelaunch response versus scan-angle (RVS) is tracked and linearly scaled on-orbit using observations at two AOIs of 11.2deg and 50.2deg corresponding to the moon view and solar diffuser, respectively. As the missions continue to operate well beyond their design life of 6 years, the assumption of linear scaling between the two AOIs is known to be inadequate in accurately characterizing the RVS, particularly at short wavelengths. Consequently, an enhanced approach of supplementing the on-board measurements with response trends from desert pseudo-invariant calibration sites (PICS) was formulated in MODIS Collection 6 (C6). An underlying assumption for the continued effectiveness of this approach is the long-term (multi-year) and short-term (month-to-month) stability of the PICS. Previous work has shown that the deep convective clouds (DCC) can also be used to monitor the on-orbit RVS performance with less trend uncertainties than desert sites. In this paper, the raw sensor response to the DCC is used to characterize the on-orbit RVS on a band and mirror side basis. These DCC-based RVS results are compared with the C6 PICS-based RVS, showing an agreement within 2% observed in most cases. The pros and cons of using a DCC-based RVS approach are also discussed in this paper. Although this reaffirms the efficacy of the C6 PICS-based RVS, the DCC-based RVS approach presents itself as an effective alternative for future considerations. Potential applications of this approach to other instruments such as SNPP and JPSS VIIRS are also discussed

    Representation of tropical deep convection in atmospheric models - Part 1 : Meteorology and comparison with satellite observations

    Get PDF
    Published under Creative Commons Licence 3.0. Original article can be found at : http://www.atmospheric-chemistry-and-physics.net/ "The author's copyright for this publication is transferred to University of Hertfordshire".Fast convective transport in the tropics can efficiently redistribute water vapour and pollutants up to the upper troposphere. In this study we compare tropical convection characteristics for the year 2005 in a range of atmospheric models, including numerical weather prediction (NWP) models, chemistry transport models (CTMs), and chemistry-climate models (CCMs). The model runs have been performed within the framework of the SCOUT-O3 (Stratospheric-Climate Links with Emphasis on the Upper Troposphere and Lower Stratosphere) project. The characteristics of tropical convection, such as seasonal cycle, land/sea contrast and vertical extent, are analysed using satellite observations as a benchmark for model simulations. The observational datasets used in this work comprise precipitation rates, outgoing longwave radiation, cloud-top pressure, and water vapour from a number of independent sources, including ERA-Interim analyses. Most models are generally able to reproduce the seasonal cycle and strength of precipitation for continental regions but show larger discrepancies with observations for the Maritime Continent region. The frequency distribution of high clouds from models and observations is calculated using highly temporally-resolved (up to 3-hourly) cloud top data. The percentage of clouds above 15 km varies significantly between the models. Vertical profiles of water vapour in the upper troposphere-lower stratosphere (UTLS) show large differences between the models which can only be partly attributed to temperature differences. If a convective plume reaches above the level of zero net radiative heating, which is estimated to be ~15 km in the tropics, the air detrained from it can be transported upwards by radiative heating into the lower stratosphere. In this context, we discuss the role of tropical convection as a precursor for the transport of short-lived species into the lower stratosphere.Peer reviewe

    The Calibration of the DSCOVR EPIC Multiple Visible Channel Instrument Using MODIS and VIIRS as a Reference

    Get PDF
    The Deep Space Climate Observatory (DSCOVR), launched on 11 February 2015, is a satellite positioned near the Lagrange-1 (L1) point, carrying several instruments that monitor space weather, and Earth-view sensors designed for climate studies. The Earth Polychromatic Imaging Camera (EPIC) onboard DSCOVR continuously views the sun-illuminated portion of the Earth with spectral coverage in the UV, VIS, and NIR bands. Although the EPIC instrument does not have any onboard calibration abilities, its constant view of the sunlit Earth disk provides a unique opportunity for simultaneous viewing with several other satellite instruments. This arrangement allows the EPIC sensor to be inter-calibrated using other well-characterized satellite instrument reference standards. Two such instruments with onboard calibration are MODIS, flown on Aqua and Terra, and VIIRS, onboard Suomi-NPP. The MODIS and VIIRS reference calibrations will be transferred to the EPIC instrument using both all-sky ocean and deep convective clouds (DCC) ray-matched EPIC and MODIS/VIIRS radiance pairs. An automated navigation correction routine was developed to more accurately align the EPIC and MODIS/VIIRS granules. The automated navigation correction routine dramatically reduced the uncertainty of the resulting calibration gain based on the EPIC and MODIS/VIIRS radiance pairs. The SCIAMACHY-based spectral band adjustment factors (SBAF) applied to the MODIS/ VIIRS radiances were found to successfully adjust the reference radiances to the spectral response of the specific EPIC channel for over-lapping spectral channels. The SBAF was also found to be effective for the non-overlapping EPIC channel 10. Lastly, both ray-matching techniques found no discernable trends for EPIC channel 7 over the year of publically released EPIC data

    Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

    Get PDF
    Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality

    Vicarious Methodologies to Assess and Improve the Quality of the Optical Remote Sensing Images: A Critical Review

    Get PDF
    Over the past decade, number of optical Earth observing satellites performing remote sensing has increased substantially, dramatically increasing the capability to monitor the Earth. The quantity of remote sensing satellite increase is primarily driven by improved technology, miniaturization of components, reduced manufacturing, and launch cost. These satellites often lack on-board calibrators that a large satellite utilizes to ensure high quality (e.g., radiometric, geometric, spatial quality, etc.) scientific measurement. To address this issue, this work presents “best” vicarious image quality assessment and improvement techniques for those kinds of optical satellites which lacks on-board calibration system. In this article, image quality categories have been explored, and essential quality parameters (e.g., absolute and relative calibration, aliasing, etc.) have been identified. For each of the parameters, appropriate characterization methods are identified along with its specifications or requirements. In cases of multiple methods, recommendation has been made based-on the strengths and weaknesses of each method. Furthermore, processing steps have been presented, including examples. Essentially, this paper provides a comprehensive study of the criteria that needs to be assessed to evaluate remote sensing satellite data quality, and best vicarious methodologies to evaluate identified quality parameters such as coherent noise, ground sample distance, etc

    The Calibration of AVHRR Visible Dual Gain using Meteosat-8 for NOAA-16 to 18

    Get PDF
    The NOAA AVHRR program has given the remote sensing community over 25 years of imager radiances to retrieve global cloud, vegetation, and aerosol properties. This dataset can be used for long-term climate research, if the AVHRR instrument is well calibrated. Unfortunately, the AVHRR instrument does not have onboard visible calibration and does degrade over time. Vicarious post-launch calibration is necessary to obtain cloud properties that are not biased over time. The recent AVHRR-3 instrument has a dual gain in the visible channels in order to achieve greater radiance resolution in the clear-sky. This has made vicarious calibration of the AVHRR-3 more difficult to unravel. Reference satellite radiances from well-calibrated instruments, usually equipped with solar diffusers, such as MODIS, have been used to successfully vicariously calibrate other visible instruments. Transfer of calibration from one satellite to another using co-angled, collocated, coincident radiances has been well validated. Terra or Aqua MODIS and AVHRR comparisons can only be performed over the poles during summer. However, geostationary satellites offer a transfer medium that captures both parts of the dual gain. This AVHRR-3 calibration strategy uses, calibrated with MODIS, Meteosat-8 radiances simultaneously to determine the dual gains using 50km regions. The dual gain coefficients will be compared with the nominal coefficients. Results will be shown for all visible channels for NOAA-17

    Calibrating Historical IR Sensors Using GEO, and AVHRR Infrared Tropical Mean Calibration Models

    Get PDF
    Long-term, remote-sensing-based climate data records (CDRs) are highly dependent on having consistent, wellcalibrated satellite instrument measurements of the Earth's radiant energy. Therefore, by making historical satellite calibrations consistent with those of today's imagers, the Earth-observing community can benefit from a CDR that spans a minimum of 30 years. Most operational meteorological satellites rely on an onboard blackbody and space looks to provide on-orbit IR calibration, but neither target is traceable to absolute standards. The IR channels can also be affected by ice on the detector window, angle dependency of the scan mirror emissivity, stray-light, and detector-to-detector striping. Being able to quantify and correct such degradations would mean IR data from any satellite imager could contribute to a CDR. Recent efforts have focused on utilizing well-calibrated modern hyper-spectral sensors to intercalibrate concurrent operational IR imagers to a single reference. In order to consistently calibrate both historical and current IR imagers to the same reference, however, another strategy is needed. Large, well-characterized tropical-domain Earth targets have the potential of providing an Earth-view reference accuracy of within 0.5 K. To that effort, NASA Langley is developing an IR tropical mean calibration model in order to calibrate historical Advanced Very High Resolution Radiometer (AVHRR) instruments. Using Meteosat-9 (Met-9) as a reference, empirical models are built based on spatially/temporally binned Met-9 and AVHRR tropical IR brightness temperatures. By demonstrating the stability of the Met-9 tropical models, NOAA-18 AVHRR can be calibrated to Met-9 by matching the AVHRR monthly histogram averages with the Met-9 model. This method is validated with ray-matched AVHRR and Met-9 biasdifference time series. Establishing the validity of this empirical model will allow for the calibration of historical AVHRR sensors to within 0.5 K, and thereby establish a climate-quality IR data record