2,628 research outputs found

    Prevalence of haptic feedback in robot-mediated surgery : a systematic review of literature

    Get PDF
    © 2017 Springer-Verlag. This is a post-peer-review, pre-copyedit version of an article published in Journal of Robotic Surgery. The final authenticated version is available online at: https://doi.org/10.1007/s11701-017-0763-4With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.Peer reviewe

    Design and Evaluation of Neurosurgical Training Simulator

    Get PDF
    Surgical simulators are becoming more important in surgical training. Consumer smartphone technology has improved to allow deployment of VR applications and are now being targeted for medical training simulators. A surgical simulator has been designed using a smartphone, Google cardboard 3D glasses, and the Leap Motion (LM) hand controller. Two expert and 16 novice users were tasked with completing the same pointing tasks using both the LM and the medical simulator NeuroTouch. The novice users had an accuracy of 0.2717 bits (SD 0.3899) and the experts had an accuracy of 0.0925 bits (SD 0.1210) while using the NeuroTouch. Novices and experts improved their accuracy to 0.3585 bits (SD 0.4474) and 0.4581 bits (SD 0.3501) while using the LM. There were some tracking problems with the AR display and LM. Users were intrigued by the AR display and most preferred the LM, as they found it to have better usability

    Benchtop simulation of the retrosigmoid approach: Validation of a surgical simulator and development of a task-specific outcome measure score

    Get PDF
    Background: Neurosurgical training is changing globally. Reduced working hours and training opportunities, increased patient safety expectations, and the impact of COVID-19 have reduced operative exposure. Benchtop simulators enable trainees to develop surgical skills in a controlled environment. We aim to validate a highfidelity simulator model (RetrosigmoidBox, UpSurgeOn) for the retrosigmoid approach to the cerebellopontine angle (CPA). Methods: Novice and expert Neurosurgeons and Ear, Nose, and Throat surgeons performed a surgical task using the model – identification of the trigeminal nerve. Experts completed a post-task questionnaire examining face and content validity. Construct validity was assessed through scoring of operative videos employing Objective Structured Assessment of Technical Skills (OSATS) and a novel Task-Specific Outcome Measure score. Results: Fifteen novice and five expert participants were recruited. Forty percent of experts agreed or strongly agreed that the brain tissue looked real. Experts unanimously agreed that the RetrosigmoidBox was appropriate for teaching. Statistically significant differences were noted in task performance between novices and experts, demonstrating construct validity. Median total OSATS score was 14/25 (IQR 10–19) for novices and 22/25 (IQR 20–22) for experts (p < 0.05). Median Task-Specific Outcome Measure score was 10/20 (IQR 7–17) for novices compared to 19/20 (IQR 18.5–19.5) for experts (p < 0.05). Conclusion: The RetrosigmoidBox benchtop simulator has a high degree of content and construct validity and moderate face validity. The changing landscape of neurosurgical training mean that simulators are likely to become increasingly important in the delivery of high-quality education. We demonstrate the validity of a TaskSpecific Outcome Measure score for performance assessment of a simulated approach to the CPA

    Filling the gap between the OR and virtual simulation : a European study on a basic neurosurgical procedure

    Get PDF
    Aki Laakso tutkimusryhmÀn jÀsenenÀ.Currently available simulators are supposed to allow young neurosurgeons to hone their technical skills in a safe environment, without causing any unnecessary harm to their patients caused by their inexperience. For this training method to be largely accepted in neurosurgery, it is necessary to prove simulation efficacy by means of large-scale clinical validation studies. We correlated and analysed the performance at a simulator and the actual operative skills of different neurosurgeons (construct validity). We conducted a study involving 92 residents and attending neurosurgeons from different European Centres; each participant had to perform a virtual task, namely the placement of an external ventricular drain (EVD) at a neurosurgical simulator (ImmersiveTouch). The number of attempts needed to reach the ventricles and the accuracy in positioning the catheter were assessed. Data suggests a positive correlation between subjects who placed more EVDs in the previous year and those who get better scores at the simulator (p = .008) (fewer attempts and better surgical accuracy). The number of attempts to reach the ventricle was also analysed; senior residents needed fewer attempts (mean = 2.26; SD = 1.11) than junior residents (mean = 3.12; SD = 1.05) (p = .007) and staff neurosurgeons (mean = 2.89, SD = 1.23). Scoring results were compared by using the Fisher's test, for the analysis of the variances, and the Student's T test. Surprisingly, having a wider surgical experience overall does not correlate with the best performance at the simulator. The performance of an EVD placement on a simulator correlates with the density of the neurosurgical experience for that specific task performed in the OR, suggesting that simulators are able to differentiate neurosurgeons according to their surgical ability. Namely this suggests that the simulation performance reflects the surgeons' consistency in placing EVDs in the last year.Peer reviewe

    Performance Factors in Neurosurgical Simulation and Augmented Reality Image Guidance

    Get PDF
    Virtual reality surgical simulators have seen widespread adoption in an effort to provide safe, cost-effective and realistic practice of surgical skills. However, the majority of these simulators focus on training low-level technical skills, providing only prototypical surgical cases. For many complex procedures, this approach is deficient in representing anatomical variations that present clinically, failing to challenge users’ higher-level cognitive skills important for navigation and targeting. Surgical simulators offer the means to not only simulate any case conceivable, but to test novel approaches and examine factors that influence performance. Unfortunately, there is a void in the literature surrounding these questions. This thesis was motivated by the need to expand the role of surgical simulators to provide users with clinically relevant scenarios and evaluate human performance in relation to image guidance technologies, patient-specific anatomy, and cognitive abilities. To this end, various tools and methodologies were developed to examine cognitive abilities and knowledge, simulate procedures, and guide complex interventions all within a neurosurgical context. The first chapter provides an introduction to the material. The second chapter describes the development and evaluation of a virtual anatomical training and examination tool. The results suggest that learning occurs and that spatial reasoning ability is an important performance predictor, but subordinate to anatomical knowledge. The third chapter outlines development of automation tools to enable efficient simulation studies and data management. In the fourth chapter, subjects perform abstract targeting tasks on ellipsoid targets with and without augmented reality guidance. While the guidance tool improved accuracy, performance with the tool was strongly tied to target depth estimation – an important consideration for implementation and training with similar guidance tools. In the fifth chapter, neurosurgically experienced subjects were recruited to perform simulated ventriculostomies. Results showed anatomical variations influence performance and could impact outcome. Augmented reality guidance showed no marked improvement in performance, but exhibited a mild learning curve, indicating that additional training may be warranted. The final chapter summarizes the work presented. Our results and novel evaluative methodologies lay the groundwork for further investigation into simulators as versatile research tools to explore performance factors in simulated surgical procedures

    A new head-mounted display-based augmented reality system in neurosurgical oncology: a study on phantom

    Get PDF
    Purpose: Benefits of minimally invasive neurosurgery mandate the development of ergonomic paradigms for neuronavigation. Augmented Reality (AR) systems can overcome the shortcomings of commercial neuronavigators. The aim of this work is to apply a novel AR system, based on a head-mounted stereoscopic video see-through display, as an aid in complex neurological lesion targeting. Effectiveness was investigated on a newly designed patient-specific head mannequin featuring an anatomically realistic brain phantom with embedded synthetically created tumors and eloquent areas. Materials and methods: A two-phase evaluation process was adopted in a simulated small tumor resection adjacent to BrocaĂą\u80\u99s area. Phase I involved nine subjects without neurosurgical training in performing spatial judgment tasks. In Phase II, three surgeons were involved in assessing the effectiveness of the AR-neuronavigator in performing brain tumor targeting on a patient-specific head phantom. Results: Phase I revealed the ability of the AR scene to evoke depth perception under different visualization modalities. Phase II confirmed the potentialities of the AR-neuronavigator in aiding the determination of the optimal surgical access to the surgical target. Conclusions: The AR-neuronavigator is intuitive, easy-to-use, and provides three-dimensional augmented information in a perceptually-correct way. The system proved to be effective in guiding skin incision, craniotomy, and lesion targeting. The preliminary results encourage a structured study to prove clinical effectiveness. Moreover, our testing platform might be used to facilitate training in brain tumour resection procedures

    Systematic review of the current status of cadaveric simulation for surgical training

    Get PDF
    Background: There is growing interest in and provision of cadaveric simulation courses for surgical trainees. This is being driven by the need to modernize and improve the efficiency of surgical training within the current challenging training climate. The objective of this systematic review is to describe and evaluate the evidence for cadaveric simulation in postgraduate surgical training. Methods: A PRISMA‐compliant systematic literature review of studies that prospectively evaluated a cadaveric simulation training intervention for surgical trainees was undertaken. All relevant databases and trial registries were searched to January 2019. Methodological rigour was assessed using the widely validated Medical Education Research Quality Index (MERSQI) tool. Results: A total of 51 studies were included, involving 2002 surgical trainees across 69 cadaveric training interventions. Of these, 22 assessed the impact of the cadaveric training intervention using only subjective measures, five measured impact by change in learner knowledge, and 23 used objective tools to assess change in learner behaviour after training. Only one study assessed patient outcome and demonstrated transfer of skill from the simulated environment to the workplace. Of the included studies, 67 per cent had weak methodology (MERSQI score less than 10·7). Conclusion: There is an abundance of relatively low‐quality evidence showing that cadaveric simulation induces short‐term skill acquisition as measured by objective means. There is currently a lack of evidence of skill retention, and of transfer of skills following training into the live operating theatre

    Augmented Reality Simulation Modules for EVD Placement Training and Planning Aids

    Get PDF
    When a novice neurosurgeon performs a psychomotor surgical task (e.g., tool navigation into brain structures), a potential risk of damaging healthy tissues and eloquent brain structures is unavoidable. When novices make multiple hits, thus a set of undesirable trajectories is created, and resulting in the potential for surgical complications. Thus, it is important that novices not only aim for a high-level of surgical mastery but also receive deliberate training in common neurosurgical procedures and underlying tasks. Surgical simulators have emerged as an adequate candidate as effective method to teach novices in safe and free-error training environments. The design of neurosurgical simulators requires a comprehensive approach to development and. In that in mind, we demonstrate a detailed case study in which two Augmented Reality (AR) training simulation modules were designed and implemented through the adoption of Model-driven Engineering. User performance evaluation is a key aspect of the surgical simulation validity. Many AR surgical simulators become obsolete; either they are not sufficient to support enough surgical scenarios, or they were validated according to subjective assessments that did not meet every need. Accordingly, we demonstrate the feasibility of the AR simulation modules through two user studies, objectively measuring novices’ performance based on quantitative metrics. Neurosurgical simulators are prone to perceptual distance underestimation. Few investigations were conducted for improving user depth perception in head-mounted display-based AR systems with perceptual motion cues. Consequently, we report our investigation’s results about whether or not head motion and perception motion cues had an influence on users’ performance

    Evaluating Human Performance for Image-Guided Surgical Tasks

    Get PDF
    The following work focuses on the objective evaluation of human performance for two different interventional tasks; targeted prostate biopsy tasks using a tracked biopsy device, and external ventricular drain placement tasks using a mobile-based augmented reality device for visualization and guidance. In both tasks, a human performance methodology was utilized which respects the trade-off between speed and accuracy for users conducting a series of targeting tasks using each device. This work outlines the development and application of performance evaluation methods using these devices, as well as details regarding the implementation of the mobile AR application. It was determined that the Fitts’ Law methodology can be applied for evaluation of tasks performed in each surgical scenario, and was sensitive to differentiate performance across a range which spanned experienced and novice users. This methodology is valuable for future development of training modules for these and other medical devices, and can provide details about the underlying characteristics of the devices, and how they can be optimized with respect to human performance
    • 