498 research outputs found

    Automated Detection of Left Ventricle in Arterial Input Function Images for Inline Perfusion Mapping using Deep Learning: A study of 15,000 Patients

    Get PDF
    Quantification of myocardial perfusion has the potential to improve detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Since failure here invalidates quantification, high accuracy is required. For this purpose, this study presents a robust AIF detection method using the convolutional neural net (CNN) model. CNN models were trained by assembling 25,027 scans (N=12,984 patients) from three hospitals, seven scanners. A test set of 5,721 scans (N=2,805 patients) evaluated model performance. The 2D+T AIF time series was inputted into CNN. Two variations were investigated: a) Two Classes (2CS) for background and foreground (LV mask); b) Three Classes (3CS) for background, foreground LV and RV. Final model was deployed on MR scanners via the Gadgetron InlineAI. Model loading time on MR scanner was ~340ms and applying it took ~180ms. The 3CS model successfully detect LV for 99.98% of all test cases (1 failed out of 5,721 cases). The mean Dice ratio for 3CS was 0.87+/-0.08 with 92.0% of all test cases having Dice ratio >0.75, while the 2CS model gave lower Dice of 0.82+/-0.22 (P<1e-5). Extracted AIF signals using CNN were further compared to manual ground-truth for foot-time, peak-time, first-pass duration, peak value and area-under-curve. No significant differences were found for all features (P>0.2). This study proposed, validated, and deployed a robust CNN solution to detect the LV for the extraction of the AIF signal used in fully automated perfusion flow mapping. A very large data cohort was assembled and resulting models were deployed to MR scanners for fully inline AI in clinical hospitals.Comment: Accepted by Magnetic Resonance in Medicine on March 30, 202

    Multi-modality cardiac image computing: a survey

    Get PDF
    Multi-modality cardiac imaging plays a key role in the management of patients with cardiovascular diseases. It allows a combination of complementary anatomical, morphological and functional information, increases diagnosis accuracy, and improves the efficacy of cardiovascular interventions and clinical outcomes. Fully-automated processing and quantitative analysis of multi-modality cardiac images could have a direct impact on clinical research and evidence-based patient management. However, these require overcoming significant challenges including inter-modality misalignment and finding optimal methods to integrate information from different modalities. This paper aims to provide a comprehensive review of multi-modality imaging in cardiology, the computing methods, the validation strategies, the related clinical workflows and future perspectives. For the computing methodologies, we have a favored focus on the three tasks, i.e., registration, fusion and segmentation, which generally involve multi-modality imaging data, either combining information from different modalities or transferring information across modalities. The review highlights that multi-modality cardiac imaging data has the potential of wide applicability in the clinic, such as trans-aortic valve implantation guidance, myocardial viability assessment, and catheter ablation therapy and its patient selection. Nevertheless, many challenges remain unsolved, such as missing modality, modality selection, combination of imaging and non-imaging data, and uniform analysis and representation of different modalities. There is also work to do in defining how the well-developed techniques fit in clinical workflows and how much additional and relevant information they introduce. These problems are likely to continue to be an active field of research and the questions to be answered in the future

    Artificial Intelligence Will Transform Cardiac Imaging-Opportunities and Challenges

    Get PDF
    National Institute for Health Research (NIHR) Cardiovascular Biomedical Research Center at BartsSmartHeart EPSRC programme grant (www.nihr.ac.uk; EP/P001009/1)London Medical Imaging and AI Center for Value-Based HealthcareCAP-AI programmeEuropean Union's Horizon 2020 research and innovation programme under grant agreement No 825903

    ISLES 2015 - A public evaluation benchmark for ischemic stroke lesion segmentation from multispectral MRI

    Get PDF
    Ischemic stroke is the most common cerebrovascular disease, and its diagnosis, treatment, and study relies on non-invasive imaging. Algorithms for stroke lesion segmentation from magnetic resonance imaging (MRI) volumes are intensely researched, but the reported results are largely incomparable due to different datasets and evaluation schemes. We approached this urgent problem of comparability with the Ischemic Stroke Lesion Segmentation (ISLES) challenge organized in conjunction with the MICCAI 2015 conference. In this paper we propose a common evaluation framework, describe the publicly available datasets, and present the results of the two sub-challenges: Sub-Acute Stroke Lesion Segmentation (SISS) and Stroke Perfusion Estimation (SPES). A total of 16 research groups participated with a wide range of state-of-the-art automatic segmentation algorithms. A thorough analysis of the obtained data enables a critical evaluation of the current state-of-the-art, recommendations for further developments, and the identification of remaining challenges. The segmentation of acute perfusion lesions addressed in SPES was found to be feasible. However, algorithms applied to sub-acute lesion segmentation in SISS still lack accuracy. Overall, no algorithmic characteristic of any method was found to perform superior to the others. Instead, the characteristics of stroke lesion appearances, their evolution, and the observed challenges should be studied in detail. The annotated ISLES image datasets continue to be publicly available through an online evaluation system to serve as an ongoing benchmarking resource (www.isles-challenge.org).Peer reviewe

    Automatic segmentation in CMR - Development and validation of algorithms for left ventricular function, myocardium at risk and myocardial infarction

    Get PDF
    In this thesis four new algorithms are presented for automatic segmentation in cardiovascular magnetic resonance (CMR); automatic segmentation of the left ventricle, myocardial infarction, and myocardium at risk in two different image types. All four algorithms were implemented in freely available software for image analysis and were validated against reference delineations with a low bias and high regional agreement. CMR is the most accurate and reproducible method for assessment of left ventricular mass and volumes and reference standard for assessment of myocardial infarction. CMR is also validated against single photon emission computed tomography (SPECT) for assessment of myocardium at risk up to one week after acute myocardial infarction. However, the clinical standard for quantification of left ventricular mass and volumes is manual delineation which has been shown to have a large bias between observers from different sites and for myocardium at risk and myocardial infarction there is no clinical standard due to varying results shown for the previously suggested threshold methods. The new automatic algorithms were all based on intensity classification by Expectation Maximization (EM) and incorporation of a priori information specific for each application. Validation was performed in large cohorts of patients with regards to bias in clinical parameters and regional agreement as Dice Similarity Coefficient (DSC). Further, images with reference delineation of the left ventricle were made available for future benchmarking of left ventricular segmentation, and the new automatic algorithms for segmentation of myocardium at risk and myocardial infarction were directly compared to the previously suggested intensity threshold methods. Combining intensity classification by EM with a priori information as in the new automatic algorithms was shown superior to previous methods and specifically to the previously suggested threshold methods for myocardium at risk and myocardial infarction. Added value of using a priori information and intensity correction was shown significant measured by DSC even though not significant for bias. For the previously suggested methods of infarct quantification a poorer result was found in the new multi-center, multi-vendor patient data than in the original validation in animal studies or single center patient studies. Thus, the results in this thesis also show the importance ofusing both bias and DSC for validation and performing validation in images of representative quality as in multi-center, multi-vendor patient studies

    X\mathcal{X}-Metric: An N-Dimensional Information-Theoretic Framework for Groupwise Registration and Deep Combined Computing

    Full text link
    This paper presents a generic probabilistic framework for estimating the statistical dependency and finding the anatomical correspondences among an arbitrary number of medical images. The method builds on a novel formulation of the NN-dimensional joint intensity distribution by representing the common anatomy as latent variables and estimating the appearance model with nonparametric estimators. Through connection to maximum likelihood and the expectation-maximization algorithm, an information\hyp{}theoretic metric called X\mathcal{X}-metric and a co-registration algorithm named X\mathcal{X}-CoReg are induced, allowing groupwise registration of the NN observed images with computational complexity of O(N)\mathcal{O}(N). Moreover, the method naturally extends for a weakly-supervised scenario where anatomical labels of certain images are provided. This leads to a combined\hyp{}computing framework implemented with deep learning, which performs registration and segmentation simultaneously and collaboratively in an end-to-end fashion. Extensive experiments were conducted to demonstrate the versatility and applicability of our model, including multimodal groupwise registration, motion correction for dynamic contrast enhanced magnetic resonance images, and deep combined computing for multimodal medical images. Results show the superiority of our method in various applications in terms of both accuracy and efficiency, highlighting the advantage of the proposed representation of the imaging process
    corecore