195 research outputs found

    Dual Output Regulating Rectifier for an Implantable Neural Interface

    Get PDF
    This paper presents the design of a power management circuit consisting of a dual output regulating rectifier configuration featuring pulse width modulation (PWM) and pulse frequency modulation (PFM) to control the regulated output of 1.8 V, and 3.3 V from a single input ac voltage. The PFM control feedback consists of feedback-driven regulation to adjust the driving frequency of the power transistors through the buffers in the active rectifier. The PWM mode control provides a feedback loop to accurately adjust the conduction duration. The design also includes an adiabatic charge pump (CP) to power stimulators in an implantable neural interface. The adiabatic CP consists of latch up and power saving topologies to enhance its energy efficiency. Simulation results show that the dual regulating rectifier has 94.3% voltage conversion efficiency with an ac input magnitude of 3.5 Vp. The power transfer efficiency of the regulated 3.3 V output voltage is 82.3%. The dual output regulating rectifier topology is suitable for multi-functional implantable devices. The adiabatic CP has an overall efficiency of 92.9% with an overall on-chip capacitance of 60 pF. The circuit was designed in a 180-nm CMOS technology

    Low power circuits and systems for wireless neural stimulation

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011.Cataloged from PDF version of thesis.Includes bibliographical references (p. 155-161).Electrical stimulation of tissues is an increasingly valuable tool for treating a variety of disorders, with applications including cardiac pacemakers, cochlear implants, visual prostheses, deep brain stimulators, spinal cord stimulators, and muscle stimulators. Brain implants for paralysis treatments are increasingly providing sensory feedback via neural stimulation. Within the field of neuroscience, the perturbation of neuronal circuits wirelessly in untethered, freely-behaving animals is of particular importance. In implantable systems, power consumption is often the limiting factor in determining battery or power coil size, cost, and level of tissue heating, with stimulation circuitry typically dominating the power budget of the entire implant. Thus, there is strong motivation to improve the energy efficiency of implantable electrical stimulators. In this thesis, I present two examples of low-power tissue stimulators. The first type is a wireless, low-power neural stimulation system for use in freely behaving animals. The system consists of an external transmitter and a miniature, implantable wireless receiver-and-stimulator utilizing a custom integrated chip built in a standard 0.5 ptm CMOS process. Low power design permits 12 days of continuous experimentation from a 5 mAh battery, extended by an automatic sleep mode that reduces standby power consumption by 2.5x. To test this device, bipolar stimulating electrodes were implanted into the songbird motor nucleus HVC of zebra finches. Single-neuron recordings revealed that wireless stimulation of HVC led to a strong increase of spiking activity in its downstream target, the robust nucleus of the arcopallium (RA). When this device was used to deliver biphasic pulses of current randomly during singing, singing activity was prematurely terminated in all birds tested. The second stimulator I present is a novel, energy-efficient electrode stimulator with feedback current regulation. This stimulator uses inductive storage and recycling of energy based on a dynamic power supply to drive an electrode in an adiabatic fashion such that energy consumption is minimized. Since there are no explicit current sources or current limiters, wasteful energy dissipation across such elements is naturally avoided. The stimulator also utilizes a shunt current-sensor to monitor and regulate the current through the electrode via feedback, thus enabling flexible and safe stimulation. The dynamic power supply allows efficient transfer of energy both to and from the electrode, and is based on a DC-DC converter topology that is used in a bidirectional fashion. In an exemplary electrode implementation, I show how the stimulator combines the efficiency of voltage control and the safety and accuracy of current control in a single low-power integrated-circuit built in a standard 0.35 pm CMOS process. I also perform a theoretical analysis of the energy efficiency that is in accord with experimental measurements. In its current proof-of-concept implementation, this stimulator achieves a 2x-3x reduction in energy consumption as compared to a conventional current-source-based stimulator operating from a fixed power supply.by Scott Kenneth Arfin.Ph.D

    Advances in Microelectronics for Implantable Medical Devices

    Get PDF
    Implantable medical devices provide therapy to treat numerous health conditions as well as monitoring and diagnosis. Over the years, the development of these devices has seen remarkable progress thanks to tremendous advances in microelectronics, electrode technology, packaging and signal processing techniques. Many of today’s implantable devices use wireless technology to supply power and provide communication. There are many challenges when creating an implantable device. Issues such as reliable and fast bidirectional data communication, efficient power delivery to the implantable circuits, low noise and low power for the recording part of the system, and delivery of safe stimulation to avoid tissue and electrode damage are some of the challenges faced by the microelectronics circuit designer. This paper provides a review of advances in microelectronics over the last decade or so for implantable medical devices and systems. The focus is on neural recording and stimulation circuits suitable for fabrication in modern silicon process technologies and biotelemetry methods for power and data transfer, with particular emphasis on methods employing radio frequency inductive coupling. The paper concludes by highlighting some of the issues that will drive future research in the field

    High Efficiency Power Management Unit for Implantable Optical-Electrical Stimulators

    Get PDF
    Battery-less active implantable devices are of interest because they offer longer life span and eliminate costly battery replacement surgical interventions. This is possible as a result of advances in inductive power transfer and development of power management circuits to maximize the overall power transfer and provide various voltage levels for multi-functional implantable devices. Rehabilitation therapy using optical stimulation of genetically modified peripheral neurons requires high current loads. Standard rectification topologies are inefficient and have associated voltage drops unsuited for miniaturized implants. This paper presents an integrated power management unit (PMU) for an optical-electrical stimulator to be used in the treatment of motor neurone disease. It includes a power-efficient regulating rectifier with a novel body biased high-speed comparator providing 3.3 V for the operation of the stimulator, a 3-stage latch-up charge pump with 12 V output for the input stage of the optical-electrical stimulator, and 1.8 V for digital control logic. The chip was fabricated in a 0.18 μm CMOS process. Measured results show that for a regulated output of 3.3 V delivering 30.3 mW power, the peak power conversion efficiency is 84.2% at 6.78 MHz inductive link tunable frequency reducing to 70.3% at 13.56 MHz. The charge pump with on chip capacitors has 90.9% measured voltage conversion efficiency

    Circuitry for a remotely powered bio-implantable gastric electrical stimulation system

    Get PDF
    Power to bio-implantable devices is usually supplied through a battery implanted with the system or through wires extending to an outside power source. The latter case with wires protruding out of the body can be unaesthetic in appearance and can cause infection. In this research, we consider an alternative way to power a bio-implantable microsystem. It involves using rechargeable lithium batteries. Here, power is delivered remotely to charge implanted battery or batteries. This approach avoids periodic surgery necessary for battery replacement. It also does not tie a person to an external power source at all times. This improves patient’s quality of life. The present work involves design and fabrication of signal conditioning circuit for a remotely rechargeable, bio-implantable, Battery-powered Electrical Stimulation System (BESS). A rechargeable lithium ion battery with a voltage of 3.7 V powers the proposed circuit. The desired output, which goes directly to the electrodes, is a series of 10 V, 15 mA pulses with a duty cycle of 4.5 %. A second rechargeable lithium ion battery serves as back-up. A lithium ion charging chip is included which is connected to the designed IC through a logic interface. The two batteries work in tandem i.e. when one battery powers the IC the other gets recharged and vice versa thereby providing an uninterruptible output. The IC uses a series of charge pumps to get the required boost in voltage. The IC also includes voltage detector circuits to detect battery voltages, voltage regulator, pulse generator circuits, logic circuits and necessary switches. Individual subsystems of the IC were designed, simulated and fabricated using standard CMOS technology. Individual subsystem circuits were found to work satisfactorily except for the charge pump. A revised design is now under fabrication. The microsystem utilizes a hybrid approach. Experiments done with a bench-top circuit model to simulate the proposed IC showed that a 3 V battery with a capacity of 190 mAh could power the IC for 15 hrs and needed 4 hrs for recharging

    Neurostimulator with Waveforms Inspired by Nature for Wearable Electro-Acupuncture

    Get PDF
    The work presented here has 3 goals: establish the need for novel neurostimulation waveform solutions through a literature review, develop a neurostimulation pulse generator, and verify the operation of the device for neurostimulation applications. The literature review discusses the importance of stimulation waveforms on the outcomes of neurostimulation, and proposes new directions for neurostimulation research that would help in improving the reproducibility and comparability between studies. The pulse generator circuit is then described that generates signals inspired by the shape of excitatory or inhibitory post-synaptic potentials (EPSP, IPSP). The circuit analytical equations are presented, and the effects of the circuit design components are discussed. The circuit is also analyzed with a capacitive load using a simplified Randles model to represent the electrode-electrolyte interface, and the output is measured in phosphate-buffered saline (PBS) solution as the load with acupuncture needles as electrodes. The circuit is designed to be used in different types of neurostimulators depending on the needs of the application, and to study the effects of varying neurostimulation waveforms. The circuit is used to develop a remote-controlled wearable veterinary electro-acupuncture machine. The device has a small form-factor and 3D printed enclosure, and has a weight of 75 g with leads attached. The device is powered by a 500 mAh lithium polymer battery, and was tested to last 6 hours. The device is tested in an electro-acupuncture animal study on cats performed at the Louisiana State University School of Veterinary Medicine, where it showed expected electro-acupuncture effects. Then, a 2-channel implementation of the device is presented, and tested to show independent output amplitude, frequency, and stimulation duration per channel. Finally, the software and hardware requirements for control of the wearable veterinary electro-acupuncture machine are detailed. The number of output channels is limited to the number of hardware PWM timers available for use. The Arduino software implements PWM control for the output amplitude and frequency. The stimulation duration control is provided using software timers. The communications protocol between the microcontroller board and Android App are described, and communications are performed via Bluetooth

    A Closed-Loop Bidirectional Brain-Machine Interface System For Freely Behaving Animals

    Get PDF
    A brain-machine interface (BMI) creates an artificial pathway between the brain and the external world. The research and applications of BMI have received enormous attention among the scientific community as well as the public in the past decade. However, most research of BMI relies on experiments with tethered or sedated animals, using rack-mount equipment, which significantly restricts the experimental methods and paradigms. Moreover, most research to date has focused on neural signal recording or decoding in an open-loop method. Although the use of a closed-loop, wireless BMI is critical to the success of an extensive range of neuroscience research, it is an approach yet to be widely used, with the electronics design being one of the major bottlenecks. The key goal of this research is to address the design challenges of a closed-loop, bidirectional BMI by providing innovative solutions from the neuron-electronics interface up to the system level. Circuit design innovations have been proposed in the neural recording front-end, the neural feature extraction module, and the neural stimulator. Practical design issues of the bidirectional neural interface, the closed-loop controller and the overall system integration have been carefully studied and discussed.To the best of our knowledge, this work presents the first reported portable system to provide all required hardware for a closed-loop sensorimotor neural interface, the first wireless sensory encoding experiment conducted in freely swimming animals, and the first bidirectional study of the hippocampal field potentials in freely behaving animals from sedation to sleep. This thesis gives a comprehensive survey of bidirectional BMI designs, reviews the key design trade-offs in neural recorders and stimulators, and summarizes neural features and mechanisms for a successful closed-loop operation. The circuit and system design details are presented with bench testing and animal experimental results. The methods, circuit techniques, system topology, and experimental paradigms proposed in this work can be used in a wide range of relevant neurophysiology research and neuroprosthetic development, especially in experiments using freely behaving animals

    A Fully Implantable Opto-Electro Closed-Loop Neural Interface for Motor Neuron Disease Studies

    Get PDF
    This paper presents a fully implantable closed-loop device for use in freely moving rodents to investigate new treatments for motor neuron disease. The 0.18 µm CMOS integrated circuit comprises 4 stimulators, each featuring 16 channels for optical and electrical stimulation using arbitrary current waveforms at frequencies from 1.5 Hz to 50 kHz, and a bandwidth programmable front-end for neural recording. The implant uses a Qi wireless inductive link which can deliver >100 mW power at a maximum distance of 2 cm for a freely moving rodent. A backup rechargeable battery can support 10 mA continuous stimulation currents for 2.5 hours in the absence of an inductive power link. The implant is controlled by a graphic user interface with broad programmable parameters via a Bluetooth low energy bidirectional data telemetry link. The encapsulated implant is 40 mm × 20 mm × 10 mm. Measured results are presented showing the electrical performance of the electronics and the packaging method
    • …
    corecore