562 research outputs found

    Video Quality Metrics

    Get PDF

    Quality Measurements on Quantised Meshes

    Get PDF
    In computer graphics, triangle mesh has emerged as the ubiquitous shape rep- resentation for 3D modelling and visualisation applications. Triangle meshes, often undergo compression by specialised algorithms for the purposes of storage and trans- mission. During the compression processes, the coordinates of the vertices of the triangle meshes are quantised using fixed-point arithmetic. Potentially, that can alter the visual quality of the 3D model. Indeed, if the number of bits per vertex coordinate is too low, the mesh will be deemed by the user as visually too coarse as quantisation artifacts will become perceptible. Therefore, there is the need for the development of quality metrics that will enable us to predict the visual appearance of a triangle mesh at a given level of vertex coordinate quantisation

    Metrics for Stereoscopic Image Compression

    Get PDF
    Metrics for automatically predicting the compression settings for stereoscopic images, to minimize file size, while still maintaining an acceptable level of image quality are investigated. This research evaluates whether symmetric or asymmetric compression produces a better quality of stereoscopic image. Initially, how Peak Signal to Noise Ratio (PSNR) measures the quality of varyingly compressed stereoscopic image pairs was investigated. Two trials with human subjects, following the ITU-R BT.500-11 Double Stimulus Continuous Quality Scale (DSCQS) were undertaken to measure the quality of symmetric and asymmetric stereoscopic image compression. Computational models of the Human Visual System (HVS) were then investigated and a new stereoscopic image quality metric designed and implemented. The metric point matches regions of high spatial frequency between the left and right views of the stereo pair and accounts for HVS sensitivity to contrast and luminance changes in these regions. The PSNR results show that symmetric, as opposed to asymmetric stereo image compression, produces significantly better results. The human factors trial suggested that in general, symmetric compression of stereoscopic images should be used. The new metric, Stereo Band Limited Contrast, has been demonstrated as a better predictor of human image quality preference than PSNR and can be used to predict a perceptual threshold level for stereoscopic image compression. The threshold is the maximum compression that can be applied without the perceived image quality being altered. Overall, it is concluded that, symmetric, as opposed to asymmetric stereo image encoding, should be used for stereoscopic image compression. As PSNR measures of image quality are correctly criticized for correlating poorly with perceived visual quality, the new HVS based metric was developed. This metric produces a useful threshold to provide a practical starting point to decide the level of compression to use

    Digital watermarking in medical images

    Get PDF
    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University, 05/12/2005.This thesis addresses authenticity and integrity of medical images using watermarking. Hospital Information Systems (HIS), Radiology Information Systems (RIS) and Picture Archiving and Communication Systems (P ACS) now form the information infrastructure for today's healthcare as these provide new ways to store, access and distribute medical data that also involve some security risk. Watermarking can be seen as an additional tool for security measures. As the medical tradition is very strict with the quality of biomedical images, the watermarking method must be reversible or if not, region of Interest (ROI) needs to be defined and left intact. Watermarking should also serve as an integrity control and should be able to authenticate the medical image. Three watermarking techniques were proposed. First, Strict Authentication Watermarking (SAW) embeds the digital signature of the image in the ROI and the image can be reverted back to its original value bit by bit if required. Second, Strict Authentication Watermarking with JPEG Compression (SAW-JPEG) uses the same principal as SAW, but is able to survive some degree of JPEG compression. Third, Authentication Watermarking with Tamper Detection and Recovery (AW-TDR) is able to localise tampering, whilst simultaneously reconstructing the original image

    A case study in identifying acceptable bitrates for human face recognition tasks

    Get PDF
    Face recognition from images or video footage requires a certain level of recorded image quality. This paper derives acceptable bitrates (relating to levels of compression and consequently quality) of footage with human faces, using an industry implementation of the standard H.264/MPEG-4 AVC and the Closed-Circuit Television (CCTV) recording systems on London buses. The London buses application is utilized as a case study for setting up a methodology and implementing suitable data analysis for face recognition from recorded footage, which has been degraded by compression. The majority of CCTV recorders on buses use a proprietary format based on the H.264/MPEG-4 AVC video coding standard, exploiting both spatial and temporal redundancy. Low bitrates are favored in the CCTV industry for saving storage and transmission bandwidth, but they compromise the image usefulness of the recorded imagery. In this context, usefulness is determined by the presence of enough facial information remaining in the compressed image to allow a specialist to recognize a person. The investigation includes four steps: (1) Development of a video dataset representative of typical CCTV bus scenarios. (2) Selection and grouping of video scenes based on local (facial) and global (entire scene) content properties. (3) Psychophysical investigations to identify the key scenes, which are most affected by compression, using an industry implementation of H.264/MPEG-4 AVC. (4) Testing of CCTV recording systems on buses with the key scenes and further psychophysical investigations. The results showed a dependency upon scene content properties. Very dark scenes and scenes with high levels of spatial–temporal busyness were the most challenging to compress, requiring higher bitrates to maintain useful information

    1994 Science Information Management and Data Compression Workshop

    Get PDF
    This document is the proceedings from the 'Science Information Management and Data Compression Workshop,' which was held on September 26-27, 1994, at the NASA Goddard Space Flight Center, Greenbelt, Maryland. The Workshop explored promising computational approaches for handling the collection, ingestion, archival and retrieval of large quantities of data in future Earth and space science missions. It consisted of eleven presentations covering a range of information management and data compression approaches that are being or have been integrated into actual or prototypical Earth or space science data information systems, or that hold promise for such an application. The workshop was organized by James C. Tilton and Robert F. Cromp of the NASA Goddard Space Flight Center

    Perceptually lossless coding of medical images - from abstraction to reality

    Get PDF
    This work explores a novel vision model based coding approach to encode medical images at a perceptually lossless quality, within the framework of the JPEG 2000 coding engine. Perceptually lossless encoding offers the best of both worlds, delivering images free of visual distortions and at the same time providing significantly greater compression ratio gains over its information lossless counterparts. This is achieved through a visual pruning function, embedded with an advanced model of the human visual system to accurately identify and to efficiently remove visually irrelevant/insignificant information. In addition, it maintains bit-stream compliance with the JPEG 2000 coding framework and subsequently is compliant with the Digital Communications in Medicine standard (DICOM). Equally, the pruning function is applicable to other Discrete Wavelet Transform based image coders, e.g., The Set Partitioning in Hierarchical Trees. Further significant coding gains are exploited through an artificial edge segmentatio n algorithm and a novel arithmetic pruning algorithm. The coding effectiveness and qualitative consistency of the algorithm is evaluated through a double-blind subjective assessment with 31 medical experts, performed using a novel 2-staged forced choice assessment that was devised for medical experts, offering the benefits of greater robustness and accuracy in measuring subjective responses. The assessment showed that no differences of statistical significance were perceivable between the original images and the images encoded by the proposed coder
    corecore