1,712 research outputs found

    A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems

    Get PDF
    This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC) for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor interfaces are incorporated. The reconfigurable feature is effectively implemented by proposing two basis readout topologies of amplifier-based and oscillator-based circuits. For noise-immune design against various noises from inherent human-touch operations, an alternate-sampling error-correction scheme is proposed and integrated inside the ROIC, achieving a 12-bit resolution of successive approximation register (SAR) of analog-to-digital conversion without additional calibrations. A ROIC prototype that includes the whole proposed functions and data converters was fabricated in a 0.18 ??m complementary metal oxide semiconductor (CMOS) process, and its feasibility was experimentally verified to support multiple heterogeneous sensing functions of touch, electrocardiogram, body impedance, and environmental sensors.ope

    A Biosensor-CMOS Platform and Integrated Readout Circuit in 0.18-μm CMOS Technology for Cancer Biomarker Detection

    Get PDF
    This paper presents a biosensor-CMOS platform for measuring the capacitive coupling of biorecognition elements. The biosensor is designed, fabricated, and tested for the detection and quantification of a protein that reveals the presence of early-stage cancer. For the first time, the spermidine/spermine N1 acetyltransferase (SSAT) enzyme has been screened and quantified on the surface of a capacitive sensor. The sensor surface is treated to immobilize antibodies, and the baseline capacitance of the biosensor is reduced by connecting an array of capacitors in series for fixed exposure area to the analyte. A large sensing area with small baseline capacitance is implemented to achieve a high sensitivity to SSAT enzyme concentrations. The sensed capacitance value is digitized by using a 12-bit highly digital successive-approximation capacitance-to-digital converter that is implemented in a 0.18 μm CMOS technology. The readout circuit operates in the near-subthreshold regime and provides power and area efficient operation. The capacitance range is 16.137 pF with a 4.5 fF absolute resolution, which adequately covers the concentrations of 10 mg/L, 5 mg/L, 2.5 mg/L, and 1.25 mg/L of the SSAT enzyme. The concentrations were selected as a pilot study, and the platform was shown to demonstrate high sensitivity for SSAT enzymes on the surface of the capacitive sensor. The tested prototype demonstrated 42.5 μS of measurement time and a total power consumption of 2.1 μW

    Comparison of Two Low-Power Electronic Interfaces for Capacitive Mems Sensors

    Get PDF
    The paper discusses the importance and the issues of interfacing capacitive sensors. Two architectures applicable for interfacing capacitive sensors are presented. The first solution was designed to interface a capacitive humidity sensor designed and built for a humidity-dependent monolithic capacitor developed at Budapest University of Technology and Economics. The second case presents the possible read-out solutions for a SOI-MEMS accelerometer. Both of the architectures were built and tested in a discrete implementation to qualify the methods before the integrated realization. The paper presents a detailed comparison of the two methodsComment: Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/EDA-Publishing

    Design of a Programmable Passive SoC for Biomedical Applications Using RFID ISO 15693/NFC5 Interface

    Get PDF
    Low power, low cost inductively powered passive biotelemetry system involving fully customized RFID/NFC interface base SoC has gained popularity in the last decades. However, most of the SoCs developed are application specific and lacks either on-chip computational or sensor readout capability. In this paper, we present design details of a programmable passive SoC in compliance with ISO 15693/NFC5 standard for biomedical applications. The integrated system consists of a 32-bit microcontroller, a sensor readout circuit, a 12-bit SAR type ADC, 16 kB RAM, 16 kB ROM and other digital peripherals. The design is implemented in a 0.18 μ m CMOS technology and used a die area of 1.52 mm × 3.24 mm. The simulated maximum power consumption of the analog block is 592 μ W. The number of external components required by the SoC is limited to an external memory device, sensors, antenna and some passive components. The external memory device contains the application specific firmware. Based on the application, the firmware can be modified accordingly. The SoC design is suitable for medical implants to measure physiological parameters like temperature, pressure or ECG. As an application example, the authors have proposed a bioimplant to measure arterial blood pressure for patients suffering from Peripheral Artery Disease (PAD)

    Interface Circuits for Microsensor Integrated Systems

    Get PDF
    ca. 200 words; this text will present the book in all promotional forms (e.g. flyers). Please describe the book in straightforward and consumer-friendly terms. [Recent advances in sensing technologies, especially those for Microsensor Integrated Systems, have led to several new commercial applications. Among these, low voltage and low power circuit architectures have gained growing attention, being suitable for portable long battery life devices. The aim is to improve the performances of actual interface circuits and systems, both in terms of voltage mode and current mode, in order to overcome the potential problems due to technology scaling and different technology integrations. Related problems, especially those concerning parasitics, lead to a severe interface design attention, especially concerning the analog front-end and novel and smart architecture must be explored and tested, both at simulation and prototype level. Moreover, the growing demand for autonomous systems gets even harder the interface design due to the need of energy-aware cost-effective circuit interfaces integrating, where possible, energy harvesting solutions. The objective of this Special Issue is to explore the potential solutions to overcome actual limitations in sensor interface circuits and systems, especially those for low voltage and low power Microsensor Integrated Systems. The present Special Issue aims to present and highlight the advances and the latest novel and emergent results on this topic, showing best practices, implementations and applications. The Guest Editors invite to submit original research contributions dealing with sensor interfacing related to this specific topic. Additionally, application oriented and review papers are encouraged.

    Wide Dynamic Range CMOS Potentiostat for Amperometric Chemical Sensor

    Get PDF
    Presented is a single-ended potentiostat topology with a new interface connection between sensor electrodes and potentiostat circuit to avoid deviation of cell voltage and linearly convert the cell current into voltage signal. Additionally, due to the increased harmonic distortion quantity when detecting low-level sensor current, the performance of potentiostat linearity which causes the detectable current and dynamic range to be limited is relatively decreased. Thus, to alleviate these irregularities, a fully-differential potentiostat is designed with a wide output voltage swing compared to single-ended potentiostat. Two proposed potentiostats were implemented using TSMC 0.18-μm CMOS process for biomedical application. Measurement results show that the fully differential potentiostat performs relatively better in terms of linearity when measuring current from 500 pA to 10 uA. Besides, the dynamic range value can reach a value of 86 dB

    Novel Current-Mode Sensor Interfacing and Radio Blocks for Cell Culture Monitoring

    No full text
    Since 2004 Imperial College has been developing the world’s first application-specific instrumentation aiming at the on-line, in-situ, physiochemical monitoring of adult stem cell cultures. That effort is internationally known as the ‘Intelligent Stem Cell Culture Systems’ (ISCCS) project. The ISCCS platform is formed by the functional integration of biosensors, interfacing electronics and bioreactors. Contrary to the PCB-level ISCCS platform the work presented in this thesis relates to the realization of a miniaturized cell culture monitoring platform. Specifically, this thesis details the synthesis and fabrication of pivotal VLSI circuit blocks suitable for the construction of a miniaturized microelectronic cell monitoring platform. The thesis is composed of two main parts. The first part details the design and operation of a two-stage current-input currentoutput topology suitable for three-electrode amperometric sensor measurements. The first stage is a CMOS-dual rail-class AB-current conveyor providing a low impedancevirtual ground node for a current input. The second stage is a novel hyperbolic-sinebased externally-linear internally-non-linear current amplification stage. This stage bases its operation upon the compressive sinh−1 conversion of the interfaced current to an intermediate auxiliary voltage and the subsequent sinh expansion of the same voltage. The proposed novel topology has been simulated for current-gain values ranging from 10 to 1000 using the parameters of the commercially available 0.8μm AMS CMOS process. Measured results from a chip fabricated in the same technology are also reported. The proposed interfacing/amplification architecture consumes 0.88-95μW. The second part describes the design and practical evaluation of a 13.56MHz frequency shift keying (FSK) short-range (5cm) telemetry link suitable for the monitoring of incubated cultures. Prior to the design of the full FSK radio system, a pair of 13.56MHz antennae are characterized experimentally. The experimental S-parameter-value determination of the 13.56MHz wireless link is incorporated into the Cadence Design Framework allowing a high fidelity simulation of the reported FSK radio. The transmitter of the proposed system is a novel multi-tapped seven-stage ring-oscillator-based VCO whereas the core of the receiver is an appropriately modified phase locked loop (PLL). Simulated and measured results from a 0.8μm CMOS technology chip are reported

    A CMOS Analog Front-End for Tunnelling Magnetoresistive Spintronic Sensing Systems

    Get PDF
    This paper presents a CMOS readout circuit for an integrated and highly-sensitive tunnel-magnetoresistive (TMR) sensor. Based on the characterization of the TMR sensor in the finite-element simulation, using COMSOL Multiphysics, the circuit including a Wheatstone bridge and an analogue front-end (AFE) circuit, were designed to achieve low-noise and low-power sensing. We present a transimpedance amplifier (TIA) that biases and amplifies a TMR sensor array using switched-capacitors external noise filtering and allows the integration of TMR sensors on CMOS without decreasing the measurement resolution. Designed using TSMC 0.18 μm 1V technology, the amplifier consumes 160 nA at 1.8 V supply to achieve a dc gain of 118 dB and a bandwidth of 3.8 MHz. The results confirm that the full system is able to detect the magnetic field in the pico-Tesla range with low circuit noise (2.297 pA/√Hz) and low power consumption (86 μW). A concurrent reduction in the power consumption and attenuation of noise in TMR sensors makes them suitable for long-term deployment in spintronic sensing systems
    corecore