2,832 research outputs found
Segmentation of the left ventricle of the heart in 3-D+t MRI data using an optimized nonrigid temporal model
Modern medical imaging modalities provide large amounts of information in both the spatial and temporal domains and the incorporation of this information in a coherent algorithmic framework is a significant challenge. In this paper, we present a novel and intuitive approach to combine 3-D spatial and temporal (3-D + time) magnetic resonance imaging (MRI) data in an integrated segmentation algorithm to extract the myocardium of the left ventricle. A novel level-set segmentation process is developed that simultaneously delineates and tracks the boundaries of the left ventricle muscle. By encoding prior knowledge about cardiac temporal evolution in a parametric framework, an expectation-maximization algorithm optimally tracks the myocardial deformation over the cardiac cycle. The expectation step deforms the level-set function while the maximization step updates the prior temporal model parameters to perform the segmentation in a nonrigid sense
Automatic segmentation of the left ventricle cavity and myocardium in MRI data
A novel approach for the automatic segmentation has been developed to extract the epi-cardium and endo-cardium boundaries of the left ventricle (lv) of the heart. The developed segmentation scheme takes multi-slice and multi-phase magnetic resonance (MR) images of the heart, transversing the short-axis length from the base to the apex. Each image is taken at one instance in the heart's phase. The images are segmented using a diffusion-based filter followed by an unsupervised clustering technique and the resulting labels are checked to locate the (lv) cavity. From cardiac anatomy, the closest pool of blood to the lv cavity is the right ventricle cavity. The wall between these two blood-pools (interventricular septum) is measured to give an approximate thickness for the myocardium. This value is used when a radial search is performed on a gradient image to find appropriate robust segments of the epi-cardium boundary. The robust edge segments are then joined using a normal spline curve. Experimental results are presented with very encouraging qualitative and quantitative results and a comparison is made against the state-of-the art level-sets method
An Automatic Level Set Based Liver Segmentation from MRI Data Sets
A fast and accurate liver segmentation method is a challenging work in medical image analysis area. Liver segmentation is an important process for computer-assisted diagnosis, pre-evaluation of liver transplantation and therapy planning of liver tumors. There are several advantages of magnetic resonance imaging such as free form ionizing radiation and good contrast visualization of soft tissue. Also, innovations in recent technology and image acquisition techniques have made magnetic resonance imaging a major tool in modern medicine. However, the use of magnetic resonance images for liver segmentation has been slow when we compare applications with the central nervous systems and musculoskeletal. The reasons are irregular shape, size and position of the liver, contrast agent effects and similarities of the gray values of neighbor organs. Therefore, in this study, we present a fully automatic liver segmentation method by using an approximation of the level set based contour evolution from T2 weighted magnetic resonance data sets. The method avoids solving partial differential equations and applies only integer operations with a two-cycle segmentation algorithm. The efficiency of the proposed approach is achieved by applying the algorithm to all slices with a constant number of iteration and performing the contour evolution without any user defined initial contour. The obtained results are evaluated with four different similarity measures and they show that the automatic segmentation approach gives successful results
Recommended from our members
State of the Art of Level Set Methods in Segmentation and Registration of Medical Imaging Modalities
Segmentation of medical images is an important step in various applications such as visualization, quantitative analysis and image-guided surgery. Numerous segmentation methods have been developed in the past two decades for extraction of organ contours on medical images. Low-level segmentation methods, such as pixel-based clustering, region growing, and filter-based edge detection, require additional pre-processing and post-processing as well as considerable amounts of expert intervention or information of the objects of interest. Furthermore the subsequent analysis of segmented objects is hampered by the primitive, pixel or voxel level representations from those region-based segmentation. Deformable models, on the other hand, provide an explicit representation of the boundary and the shape of the object. They combine several desirable features such as inherent connectivity and smoothness, which counteract noise and boundary irregularities, as well as the ability to incorporate knowledge about the object of interest. However, parametric deformable models have two main limitations. First, in situations where the initial model and desired object boundary differ greatly in size and shape, the model must be re-parameterized dynamically to faithfully recover the object boundary. The second limitation is that it has difficulty dealing with topological adaptation such as splitting or merging model parts, a useful property for recovering either multiple objects or objects with unknown topology. This difficulty is caused by the fact that a new parameterization must be constructed whenever topology change occurs, which requires sophisticated schemes. Level set deformable models, also referred to as geometric deformable models, provide an elegant solution to address the primary limitations of parametric deformable models. These methods have drawn a great deal of attention since their introduction in 1988. Advantages of the contour implicit formulation of the deformable model over parametric formulation include: (1) no parameterization of the contour, (2) topological flexibility, (3) good numerical stability, (4) straightforward extension of the 2D formulation to n-D. Recent reviews on the subject include papers from Suri. In this chapter we give a general overview of the level set segmentation methods with emphasize on new frameworks recently introduced in the context of medical imaging problems. We then introduce novel approaches that aim at combining segmentation and registration in a level set formulation. Finally we review a selective set of clinical works with detailed validation of the level set methods for several clinical applications
FAME - A Flexible Appearance Modelling Environment
Combined modelling of pixel intensities and shape has proven to be a very robust and widely applicable approach to interpret images. As such the Active Appearance Model (AAM) framework has been applied to a wide variety of problems within medical image analysis. This paper summarises AAM applications within medicine and describes a public domain implementation, namely the Flexible Appearance Modelling Environment (FAME). We give guidelines for the use of this research platform, and show that the optimisation techniques used renders it applicable to interactive medical applications. To increase performance and make models generalise better, we apply parallel analysis to obtain automatic and objective model truncation. Further, two different AAM training methods are compared along with a reference case study carried out on cross-sectional short-axis cardiac magnetic resonance images and face images. Source code and annotated data sets needed to reproduce the results are put in the public domain for further investigation
A novel model-based 3D+time left ventricular segmentation technique
A common approach to model-based segmentation is to assume a top-down modelling strategy. However, this is not feasible for complex 3D+time structures such as the cardiac left ventricle due to increased training requirements, aligning difficulties and local minima in resulting models. As our main contribution, we present an alternate bottom-up modelling approach. By combining the variation captured in multiple dimensionally-targeted models at segmentation-time we create a scalable segmentation framework that does not suffer from the ’curse of dimensionality’. Our second contribution involves a flexible contour coupling technique that allows our segmentation method to adapt to unseen contour configurations outside the training set. This is used to identify the endo- and epi-cardium contours of the left ventricle by coupling them at segmentationtime, instead of at model-time. We apply our approach to 33 3D+time MRI cardiac datasets and perform comprehensive evaluation against several state-of-the-art works. Quantitative evaluation illustrates that our method requires significantly less training than state-of-the-art model-based methods, while maintaining or improving segmentation accuracy
Improved echocardiography segmentation using active shape model and optical flow
Heart disease is one of the most dangerous diseases that threaten human life. The doctor uses echocardiography to analyze heart disease. The result of echocardiography test is a video that shows the movement of the heart rate. The result of echocardiography test indicates whether the patient’s heart is normal or not by identifying a heart cavity area. Commonly it is determined by a doctor based on his own accuracy and experience. Therefore, many methods to do heart segmentation is appearing. But, the methods are a bit slow and less precise. Thus, a system that can help the doctor to analyze it better is needed. This research will develop a system that can analyze the heart rate-motion and automatically measure heart cavity area better than the existing method. This paper proposes an improved system for cardiac segmentation using median high boost filter to increase image quality, followed by the use of an active shape model and optical flow. The segmentation of the heart rate-motion and auto measurement of the heart cavity area is expected to help the doctor to analyze the condition of the patient with better accuracy. Experimental result validated our approach
- …