593 research outputs found

    A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications

    Get PDF
    This paper presents a resolution-reconfigurable wide-range resistive sensor readout interface for wireless multi-gas monitoring applications that displays results on a smartphone. Three types of sensing resolutions were selected to minimize processing power consumption, and a dual-mode front-end structure was proposed to support the detection of a variety of hazardous gases with wide range of characteristic resistance. The readout integrated circuit (ROIC) was fabricated in a 0.18 ??m CMOS process to provide three reconfigurable data conversions that correspond to a low-power resistance-to-digital converter (RDC), a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC), and a 16-bit delta-sigma modulator. For functional feasibility, a wireless sensor system prototype that included in-house microelectromechanical (MEMS) sensing devices and commercial device products was manufactured and experimentally verified to detect a variety of hazardous gases

    A miniaturised autonomous sensor based on nanowire materials platform: the SiNAPS mote

    Get PDF
    A micro-power energy harvesting system based on core(crystalline Si)-shell(amorphous Si) nanowire solar cells together with a nanowire-modified CMOS sensing platform have been developed to be used in a dust-sized autonomous chemical sensor node. The mote (SiNAPS) is augmented by low-power electronics for power management and sensor interfacing, on a chip area of 0.25mm2. Direct charging of the target battery (e.g., NiMH microbattery) is achieved with end-to-end efficiencies up to 90% at AM1.5 illumination and 80% under 100 times reduced intensity. This requires matching the voltages of the photovoltaic module and the battery circumventing maximum power point tracking. Single solar cells show efficiencies up to 10% under AM1.5 illumination and open circuit voltages, Voc, of 450-500mV. To match the battery’s voltage the miniaturised solar cells (~1mm2 area) are connected in series via wire bonding. The chemical sensor platform (mm2 area) is set up to detect hydrogen gas concentration in the low ppm range and over a broad temperature range using a low power sensing interface circuit. Using Telran TZ1053 radio to send one sample measurement of both temperature and H2 concentration every 15 seconds, the average and active power consumption for the SiNAPS mote are less than 350nW and 2.1 μW respectively. Low-power miniaturised chemical sensors of liquid analytes through microfluidic delivery to silicon nanowires are also presented. These components demonstrate the potential of further miniaturization and application of sensor nodes beyond the typical physical sensors, and are enabled by the nanowire materials platform

    Suspended 1D metal oxide nanostructure-based gas sensor

    Get PDF
    Department of Materials Science and EngineeringWe developed a novel batch fabrication technology for the ultralow-power-consumption metal oxide gas sensing platform consisting of a suspended glassy carbon heating nanostructure and hierarchical metal oxide nanostructures forests fabricated by the carbon-micro electromechanical systems (carbon-MEMS) and selective nanowire growth process. We have developed a new manufacturing process for suspended glass carbon nanostructures such as single nanowire, nano-mesh and nano-membranes fabricated using carbon-MEMS consisting of the UV-lithography and the polymer pyrolysis processes. We designed a gas sensing platform consisting of suspended glassy carbon heating nanostructures and suspended hierarchical metal oxide nanostructure forests for the sensing part. Glassy carbon structure produced by the carbon-MEMS has many advantages such as high thermal & chemical stabilities, good hardness, and good thermal & electrical characteristics. The electrical conductivity of glassy carbon nanostructures has been increased more than three times by using rapid thermal annealing (RTA) process owing to the inferior heating property of glassy carbon nano-heater in the electrical conductivity. In order to divide the suspended glassy carbon nano-heater and the suspended hierarchical metal oxide nanostructures forests, the insulating layer of HfO2 materials is a high dielectric constant and is deposited uniformly using a atomic layer deposition (ALD) process on a suspended glassy carbon nano-heater. Suspended hierarchical metal oxide nanostructures forests were grown circumferentially on the suspended HfO2/glassy carbon nano-heater using a hydrothermal method consisting of the seed deposition and the growth processes. For selective metal oxide seed layer deposition process, a short-time exposed polymer patterning process was performed using the positive photoresist. After the polymer patterning process, a metal oxide seed layer is deposited using the rf-sputtering system, followed by a metal oxide nanostructure growth process. The distinguishing architecture of a suspended hierarchical metal oxide nanostructures forests/HfO2/glassy carbon nanostructure ensures efficient mass transport to the metal oxide nanostructure detection point of the gas analyte, resulting in highly sensitive gas detection. In the absence of an external heating system, the ultralow-power-consumption gas sensing platform of a suspended hierarchical metal oxide nanostructures forests/HfO2/glassy carbon nanostructure has excellent the gas sensing characteristics.ope

    Ancient and historical systems

    Get PDF

    Polymers and plastics modified electrodes for biosensors: a review

    Get PDF
    Polymer materials offer several advantages as supports of biosensing platforms in terms of flexibility, weight, conformability, portability, cost, disposability and scope for integration. The present study reviews the field of electrochemical biosensors fabricated on modified plastics and polymers, focusing the attention, in the first part, on modified conducting polymers to improve sensitivity, selectivity, biocompatibility and mechanical properties, whereas the second part is dedicated to modified “environmentally friendly” polymers to improve the electrical properties. These ecofriendly polymers are divided into three main classes: bioplastics made from natural sources, biodegradable plastics made from traditional petrochemicals and eco/recycled plastics, which are made from recycled plastic materials rather than from raw petrochemicals. Finally, flexible and wearable lab-on-a-chip (LOC) biosensing devices, based on plastic supports, are also discussed. This review is timely due to the significant advances achieved over the last few years in the area of electrochemical biosensors based on modified polymers and aims to direct the readers to emerging trends in this field.Peer ReviewedPostprint (published version

    Nanostructure-Based Electrochemical Immunosensors as Diagnostic Tools

    Get PDF
    Electrochemical immunosensors are affinity-based biosensors characterized by several useful features such as specificity, miniaturizability, low cost and simplicity, making them very interesting for many applications in several scientific fields. One of the significant issues in the design of electrochemical immunosensors is to increase the system’s sensitivity. Different strategies have been developed, one of the most common is the use of nanostructured materials as electrode materials, nanocarriers, electroactive or electrocatalytic nanotracers because of their abilities in signal amplification and biocompatibility. In this review, we will consider some of the most used nanostruc- tures employed in the development of electrochemical immunosensors (e.g., metallic nanoparticles, graphene, carbon nanotubes) and many other still uncommon nanomaterials. Furthermore, their diagnostic applications in the last decade will be discussed, referring to two relevant issues of present-day: the detection of tumor markers and viruses

    Roadmap on semiconductor-cell biointerfaces.

    Get PDF
    This roadmap outlines the role semiconductor-based materials play in understanding the complex biophysical dynamics at multiple length scales, as well as the design and implementation of next-generation electronic, optoelectronic, and mechanical devices for biointerfaces. The roadmap emphasizes the advantages of semiconductor building blocks in interfacing, monitoring, and manipulating the activity of biological components, and discusses the possibility of using active semiconductor-cell interfaces for discovering new signaling processes in the biological world

    Nanogap Device: Fabrication and Applications

    Get PDF
    A nanogap device as a platform for nanoscale electronic devices is presented. Integrated nanostructures on the platform have been used to functionalize the nanogap for biosensor and molecular electronics. Nanogap devices have great potential as a tool for investigating physical phenomena at the nanoscale in nanotechnology. In this dissertation, a laterally self-aligned nanogap device is presented and its feasibility is demonstrated with a nano ZnO dot light emitting diode (LED) and the growth of a metallic sharp tip forming a subnanometer gap suitable for single molecule attachment. For realizing a nanoscale device, a resolution of patterning is critical, and many studies have been performed to overcome this limitation. The creation of a sub nanoscale device is still a challenge. To surmount the challenge, novel processes including double layer etch mask and crystallographic axis alignment have been developed. The processes provide an effective way for making a suspended nanogap device consisting of two self-aligned sharp tips with conventional lithography and 3-D micromachining using anisotropic wet chemical Si etching. As conventional lithography is employed, the nanogap device is fabricated in a wafer scale and the processes assure the productivity and the repeatability. The anisotropic Si etching determines a final size of the nanogap, which is independent of the critical dimension of the lithography used. A nanoscale light emitting device is investigated. A nano ZnO dot is directly integrated on a silicon nanogap device by Zn thermal oxidation followed by Ni and Zn blanket evaporation instead of complex and time consuming processes for integrating nanostructure. The electrical properties of the fabricated LED device are analyzed for its current-voltage characteristic and metal-semiconductor-metal model. Furthermore, the electroluminescence spectrum of the emitted light is measured with a monochromator implemented with a CCD camera to understand the optical properties. The atomically sharp metallic tips are grown by metal ion migration induced by high electric field across a nanogap. To investigate the growth mechanism, in-situ TEM is conducted and the growing is monitored. The grown dendrite nanostructures show less than 1nm curvature of radius. These nanostructures may be compatible for studying the electrical properties of single molecule

    Ophthalmic sensing technologies for ocular disease diagnostics

    Get PDF
    Point-of-care diagnosis and personalized treatments are critical in ocular physiology and disease. Continuous sampling of tear fluid for ocular diagnosis is a need for further exploration. Several techniques have been developed for possible ophthalmological applications, from traditional spectroscopies to wearable sensors. Contact lenses are commonly used devices for vision correction, as well as for other therapeutic and cosmetic purposes. They are increasingly being developed into ocular sensors, being used to sense and monitor biochemical analytes in tear fluid, ocular surface temperature, intraocular pressure, and pH value. These sensors have had success in detecting ocular conditions, optimizing pharmaceutical treatments, and tracking treatment efficacy in point-of-care settings. However, there is a paucity of new and effective instrumentation reported in ophthalmology. Hence, this review will summarize the applied ophthalmic technologies for ocular diagnostics and tear monitoring, including both conventional and biosensing technologies. Besides applications of smart readout devices for continuous monitoring, targeted biomarkers are also discussed for the convenience of diagnosis of various ocular diseases. A further discussion is also provided for future aspects and market requirements related to the commercialization of novel types of contact lens sensors
    corecore