5,222 research outputs found
RIDI: Robust IMU Double Integration
This paper proposes a novel data-driven approach for inertial navigation,
which learns to estimate trajectories of natural human motions just from an
inertial measurement unit (IMU) in every smartphone. The key observation is
that human motions are repetitive and consist of a few major modes (e.g.,
standing, walking, or turning). Our algorithm regresses a velocity vector from
the history of linear accelerations and angular velocities, then corrects
low-frequency bias in the linear accelerations, which are integrated twice to
estimate positions. We have acquired training data with ground-truth motions
across multiple human subjects and multiple phone placements (e.g., in a bag or
a hand). The qualitatively and quantitatively evaluations have demonstrated
that our algorithm has surprisingly shown comparable results to full Visual
Inertial navigation. To our knowledge, this paper is the first to integrate
sophisticated machine learning techniques with inertial navigation, potentially
opening up a new line of research in the domain of data-driven inertial
navigation. We will publicly share our code and data to facilitate further
research
Real-time human ambulation, activity, and physiological monitoring:taxonomy of issues, techniques, applications, challenges and limitations
Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions
Recommended from our members
Regulating stepping during fixed-speed and self-paced treadmill walking
textBackground: Treadmill walking should closely simulate overground walking for research validation and optimal skill transfer. Traditional fixed-speed treadmill (FS) walking may not simulate natural walking because of the fixed belt speed and lack of visual cues. Self-paced (SP) treadmill walking, especially feedback controlled SP treadmill walking, enables close-to-real-time belt speed changes with users' speed changes. Different sensitivity levels of SP treadmill feedback determine how fast the treadmill respond to user's speed change. Few studies have examined the differences between FS and SP treadmill walking, or the difference between sensitivity levels of SP treadmills, and their methods were questionable because of averaging kinematics and kinetics parameters, and failing to examine directly treadmill and subjects' speed data. This study compared FS with two SP modes with variation of treadmill speed and user's speed as dependent variables. Method: Thirteen young healthy subjects participated. Subjects walked on a motorized split-belt treadmill under FS, high sensitivity SP (SP-H) and low sensitivity SP (SP-L) conditions at normal walking speed. Root mean square error (RMSE) for subject's pelvis global speed (Vpg), pelvis speed with respect to treadmill speed (Vpt), and treadmill speed (Vtg) data were collected for all trials. Results: Significant condition effects were found between FS and the two SP modes in all RMSE values (p < 0.001). The two sensitivity levels of SP had similar speed patterns. Large subject Ă— condition interaction effects were found for all variables (p < 0.001). Only small subject effects were found. Conclusions: The results of the study reveal different walking patterns between FS and SP. However, the two sensitivity levels failed to differ much. More habituation time may be needed for subjects to learn to optimally respond to the SP algorithm. Future work should include training subjects for more natural responses, applying a feed-forward algorithm, and testing the effect of optic flow on FS and SP speed variation.Kinesiology and Health Educatio
Inertial sensor-based knee flexion/extension angle estimation
A new method for estimating knee joint flexion/extension angles from segment acceleration and angular velocity data is described. The approach uses a combination of Kalman filters and biomechanical constraints based on anatomical knowledge. In contrast to many recently published methods, the proposed approach does not make use of the earth’s magnetic field and hence is insensitive to the complex field distortions commonly found in modern buildings. The method was validated experimentally by calculating knee angle from measurements taken from two IMUs placed on adjacent body segments. In contrast to many previous studies which have validated their approach during relatively slow activities or over short durations, the performance of the algorithm was evaluated during both walking and running over 5 minute periods. Seven healthy subjects were tested at various speeds from 1 to 5 miles/hour. Errors were estimated by comparing the results against data obtained simultaneously from a 10 camera motion tracking system (Qualysis). The average measurement error ranged from 0.7 degrees for slow walking (1 mph) to 3.4 degrees for running (5mph). The joint constraint used in the IMU analysis was derived from the Qualysis data. Limitations of the method, its clinical application and its possible extension are discussed
Finding Your Way Back: Comparing Path Odometry Algorithms for Assisted Return.
We present a comparative analysis of inertial-based odometry algorithms for the purpose of assisted return. An assisted return system facilitates backtracking of a path previously taken, and can be particularly useful for blind pedestrians. We present a new algorithm for path matching, and test it in simulated assisted return tasks with data from WeAllWalk, the only existing data set with inertial data recorded from blind walkers. We consider two odometry systems, one based on deep learning (RoNIN), and the second based on robust turn detection and step counting. Our results show that the best path matching results are obtained using the turns/steps odometry system
Evaluating indoor positioning systems in a shopping mall : the lessons learned from the IPIN 2018 competition
The Indoor Positioning and Indoor Navigation (IPIN) conference holds an annual competition in which indoor localization systems from different research groups worldwide are evaluated empirically. The objective of this competition is to establish a systematic evaluation methodology with rigorous metrics both for real-time (on-site) and post-processing (off-site) situations, in a realistic environment unfamiliar to the prototype developers. For the IPIN 2018 conference, this competition was held on September 22nd, 2018, in Atlantis, a large shopping mall in Nantes (France). Four competition tracks (two on-site and two off-site) were designed. They consisted of several 1 km routes traversing several floors of the mall. Along these paths, 180 points were topographically surveyed with a 10 cm accuracy, to serve as ground truth landmarks, combining theodolite measurements, differential global navigation satellite system (GNSS) and 3D scanner systems. 34 teams effectively competed. The accuracy score corresponds to the third quartile (75th percentile) of an error metric that combines the horizontal positioning error and the floor detection. The best results for the on-site tracks showed an accuracy score of 11.70 m (Track 1) and 5.50 m (Track 2), while the best results for the off-site tracks showed an accuracy score of 0.90 m (Track 3) and 1.30 m (Track 4). These results showed that it is possible to obtain high accuracy indoor positioning solutions in large, realistic environments using wearable light-weight sensors without deploying any beacon. This paper describes the organization work of the tracks, analyzes the methodology used to quantify the results, reviews the lessons learned from the competition and discusses its future
Reliable and robust detection of freezing of gait episodes with wearable electronic devices
A wearable wireless sensing system for assisting patients affected by Parkinson's disease is proposed. It uses integrated micro-electro-mechanical inertial sensors able to recognize the episodes of involuntary gait freezing. The system operates in real time and is designed for outdoor and indoor applications. Standard tests were performed on a noticeable number of patients and healthy persons and the algorithm demonstrated its reliability and robustness respect to individual specific gait and postural behaviors. The overall performances of the system are excellent with a specificity higher than 97%
Mobile Quantification and Therapy Course Tracking for Gait Rehabilitation
This paper presents a novel autonomous quality metric to quantify the
rehabilitations progress of subjects with knee/hip operations. The presented
method supports digital analysis of human gait patterns using smartphones. The
algorithm related to the autonomous metric utilizes calibrated acceleration,
gyroscope and magnetometer signals from seven Inertial Measurement Unit
attached on the lower body in order to classify and generate the grading system
values. The developed Android application connects the seven Inertial
Measurement Units via Bluetooth and performs the data acquisition and
processing in real-time. In total nine features per acceleration direction and
lower body joint angle are calculated and extracted in real-time to achieve a
fast feedback to the user. We compare the classification accuracy and
quantification capabilities of Linear Discriminant Analysis, Principal
Component Analysis and Naive Bayes algorithms. The presented system is able to
classify patients and control subjects with an accuracy of up to 100\%. The
outcomes can be saved on the device or transmitted to treating physicians for
later control of the subject's improvements and the efficiency of physiotherapy
treatments in motor rehabilitation. The proposed autonomous quality metric
solution bears great potential to be used and deployed to support digital
healthcare and therapy.Comment: 5 Page
Rehabilitative devices for a top-down approach
In recent years, neurorehabilitation has moved from a "bottom-up" to a "top down" approach. This change has also involved the technological devices developed for motor and cognitive rehabilitation. It implies that during a task or during therapeutic exercises, new "top-down" approaches are being used to stimulate the brain in a more direct way to elicit plasticity-mediated motor re-learning. This is opposed to "Bottom up" approaches, which act at the physical level and attempt to bring about changes at the level of the central neural system. Areas covered: In the present unsystematic review, we present the most promising innovative technological devices that can effectively support rehabilitation based on a top-down approach, according to the most recent neuroscientific and neurocognitive findings. In particular, we explore if and how the use of new technological devices comprising serious exergames, virtual reality, robots, brain computer interfaces, rhythmic music and biofeedback devices might provide a top-down based approach. Expert commentary: Motor and cognitive systems are strongly harnessed in humans and thus cannot be separated in neurorehabilitation. Recently developed technologies in motor-cognitive rehabilitation might have a greater positive effect than conventional therapies
- …