12 research outputs found

    DESIGN, DEVELOPMENT, AND EVALUATION OF A DISCRETELY ACTUATED STEERABLE CANNULA

    Get PDF
    Needle-based procedures require the guidance of the needle to a target region to deliver therapy or to remove tissue samples for diagnosis. During needle insertion, needle deflection occurs due to needle-tissue interaction which deviates the needle from its insertion direction. Manipulating the needle at the base provides limited control over the needle trajectory after the insertion. Furthermore, some sites are inaccessible using straight-line trajectories due to delicate structures that need to be avoided. The goal of this research is to develop a discretely actuated steerable cannula to enable active trajectory corrections and achieve accurate targeting in needle-based procedures. The cannula is composed of straight segments connected by shape memory alloy (SMA) actuators and has multiple degrees-of-freedom. To control the motion of the cannula two approaches have been explored. One approach is to measure the cannula configuration directly from the imaging modality and to use this information as a feedback to control the joint motion. The second approach is a model-based controller where the strain of the SMA actuator is controlled by controlling the temperature of the SMA actuator. The constitutive model relates the stress, strain and the temperature of the SMA actuator. The uniaxial constitutive model of the SMA that describes the tensile behavior was extended to one-dimensional pure- bending case to model the phase transformation of the arc-shaped SMA wire. An experimental characterization procedure was devised to obtain the parameters of the SMA that are used in the constitutive model. Experimental results demonstrate that temperature feedback can be effectively used to control the strain of the SMA actuator and image feedback can be reliably used to control the joint motion. Using tools from differential geometry and the configuration control approach, motion planning algorithms were developed to create pre-operative plans that steer the cannula to a desired surgical site (nodule or suspicious tissue). Ultrasound-based tracking algorithms were developed to automate the needle insertion procedure using 2D ultrasound guidance. The effectiveness of the proposed in-plane and out-of-plane tracking methods were demonstrated through experiments inside tissue phantom made of gelatin and ex-vivo experiments. An optical coherence tomography probe was integrated into the cannula and in-situ microscale imaging was performed. The results demonstrate the use of the cannula as a delivery mechanism for diagnostic applications. The tools that were developed in this dissertation form the foundations of developing a complete steerable-cannula system. It is anticipated that the cannula could be used as a delivery mechanism in image-guided needle-based interventions to introduce therapeutic and diagnostic tools to a target region

    Towards a procedure-optimised steerable catheter for deep-seated neurosurgery

    Get PDF
    In recent years, steerable needles have attracted significant interest in relation to minimally invasive surgery (MIS). Specifically, the flexible, programmable bevel-tip needle (PBN) concept was successfully demonstrated in vivo in an evaluation of the feasibility of convection-enhanced delivery (CED) for chemotherapeutics within the ovine model with a 2.5 mm PBN prototype. However, further size reductions are necessary for other diagnostic and therapeutic procedures and drug delivery operations involving deep-seated tissue structures. Since PBNs have a complex cross-section geometry, standard production methods, such as extrusion, fail, as the outer diameter is reduced further. This paper presents our first attempt to demonstrate a new manufacturing method for PBNs that employs thermal drawing technology. Experimental characterisation tests were performed for the 2.5 mm PBN and the new 1.3 mm thermally drawn (TD) PBN prototype described here. The results show that thermal drawing presents a significant advantage in miniaturising complex needle structures. However, the steering behaviour was affected due to the choice of material in this first attempt, a limitation which will be addressed in future work

    Sensorisation of a novel biologically inspired flexible needle

    Get PDF
    Percutaneous interventions are commonly performed during minimally invasive brain surgery, where a straight rigid instrument is inserted through a small incision to access a deep lesion in the brain. Puncturing a vessel during this procedure can be a life-threatening complication. Embedding a forward-looking sensor in a rigid needle has been proposed to tackle this problem; however, using a rigid needle, the procedure needs to be interrupted if a vessel is detected. Steerable needle technology could be used to avoid obstacles, such as blood vessels, due to its ability to follow curvilinear paths, but research to date was lacking in this respect. This thesis aims to investigate the deployment of forward-looking sensors for vessel detection in a steerable needle. The needle itself is based on a bioinspired programmable bevel-tip needle (PBN), a multi-segment design featuring four hollow working channels. In this thesis, laser Doppler flowmetry (LDF) is initially characterised to ensure that the sensor fulfils the minimum requirements for it to be used in conjunction with the needle. Subsequently, vessel reconstruction algorithms are proposed. To determine the axial and off-axis position of the vessel with respect to the probe, successive measurements of the LDF sensor are used. Ideally, full knowledge of the vessel orientation is required to execute an avoidance strategy. Using two LDF probes and a novel signal processing method described in this thesis, the predicted possible vessel orientations can be reduced to four, a setup which is explored here to demonstrate viable obstacle detection with only partial sensor information. Relative measurements from four LDF sensors are also explored to classify possible vessel orientations in full and without ambiguity, but under the assumption that the vessel is perpendicular to the needle insertion axis. Experimental results on a synthetic grey matter phantom are presented, which confirm these findings. To release the perpendicularity assumption, the thesis concludes with the description of a machine learning technique based on a Long Short-term memory network, which enables a vessel's spatial position, cross-sectional diameter and full pose to be predicted with sub-millimetre accuracy. Simulated and in-vitro examinations of vessel detection with this approach are used to demonstrate effective predictive ability. Collectively, these results demonstrate that the proposed steerable needle sensorisation is viable and could lead to improved safety during robotic assisted needle steering interventions.Open Acces

    Monolithic self-supportive bi-directional bending pneumatic bellows catheter

    Get PDF
    The minimally invasive surgery has proven to be advantageous over conventional open surgery in terms of reduction in recovery time, patient trauma, and overall cost of treatment. To perform a minimally invasive procedure, preliminary insertion of a flexible tube or catheter is crucial without sacrificing its ability to manoeuvre. Nevertheless, despite the vast amount of research reported on catheters, the ability to implement active catheters in the minimally invasive application is still limited. To date, active catheters are made of rigid structures constricted to the use of wires or on-board power supplies for actuation, which increases the risk of damaging the internal organs and tissues. To address this issue, an active catheter made of soft, flexible and biocompatible structure, driven via nonelectric stimulus is of utmost importance. This thesis presents the development of a novel monolithic self-supportive bi-directional bending pneumatic bellows catheter using a sacrificial molding technique. As a proof of concept, in order to understand the effects of structural parameters on the bending performance of a bellows-structured actuator, a single channel circular bellows pneumatic actuator was designed. The finite element analysis was performed in order to analyze the unidirectional bending performance, while the most optimal model was fabricated for experimental validation. Moreover, to attain biocompatibility and bidirectional bending, the novel monolithic polydimethylsiloxane (PDMS)-based dual-channel square bellows pneumatic actuator was proposed. The actuator was designed with an overall cross-sectional area of 5 x 5 mm2, while the input sequence and the number of bellows were characterized to identify their effects on the bending performance. A novel sacrificial molding technique was adopted for developing the monolithic-structured actuator, which enabled simple fabrication for complex designs. The experimental validation revealed that the actuator model with a size of5 x 5 x 68.4 mm3 i.e. having the highest number of bellows, attained optimal bi-directional bending with maximum angles of -65° and 75°, and force of 0.166 and 0.221 N under left and right channel actuation, respectively, at 100 kPa pressure. The bending performance characterization and thermal insusceptibility achieved by the developed pneumatic catheter presents a promising implementation of flexibility and thermal stability for various biomedical applications, such as dialysis and cardiac catheterization

    Design, Modeling and Control of Micro-scale and Meso-scale Tendon-Driven Surgical Robots

    Get PDF
    Manual manipulation of passive surgical tools is time consuming with uncertain results in cases of navigating tortuous anatomy, avoiding critical anatomical landmarks, and reaching targets not located in the linear range of these tools. For example, in many cardiovascular procedures, manual navigation of a micro-scale passive guidewire results in increased procedure times and radiation exposure. This thesis introduces the design of two steerable guidewires: 1) A two degree-of-freedom (2-DoF) robotic guidewire with orthogonally oriented joints to access points in a three dimensional workspace, and 2) a micro-scale coaxially aligned steerable (COAST) guidewire robot that demonstrates variable and independently controlled bending length and curvature of the distal end. The 2-DoF guidewire features two micromachined joints from a tube of superelastic nitinol of outer diameter 0.78 mm. Each joint is actuated with two nitinol tendons. The joints that are used in this robot are called bidirectional asymmetric notch (BAN) joints, and the advantages of these joints are explored and analyzed. The design of the COAST robotic guidewire involves three coaxially aligned tubes with a single tendon running centrally through the length of the robot. The outer tubes are made from micromachined nitinol allowing for tendon-driven bending of the robot at variable bending curvatures, while an inner stainless steel tube controls the bending length of the robot. By varying the lengths of the tubes as well as the tendon, and by insertion and retraction of the entire assembly, various joint lengths and curvatures may be achieved. Kinematic and static models, a compact actuation system, and a controller for this robot are presented. The capability of the robot to accurately navigate through phantom anatomical bifurcations and tortuous angles is also demonstrated in three dimensional phantom vasculature. At the meso-scale, manual navigation of passive pediatric neuroendoscopes for endoscopic third ventriculostomy may not reach target locations in the patient's ventricle. This work introduces the design, analysis and control of a meso-scale two degree-of-freedom robotic bipolar electrocautery tool that increases the workspace of the neurosurgeon. A static model is proposed for the robot joints that avoids problems arising from pure kinematic control. Using this model, a control system is developed that comprises of a disturbance observer to provide precise force control and compensate for joint hysteresis. A handheld controller is developed and demonstrated in this thesis. To allow the clinician to estimate the shape of the steerable tools within the anatomy for both micro-scale and meso-scale tools, a miniature tendon force sensor and a high deflection shape sensor are proposed and demonstrated. The force sensor features a compact design consisting of a single LED, dual-phototransistor, and a dual-screen arrangement to increase the linear range of sensor output and compensate for external disturbances, thereby allowing force measurement of up to 21 N with 99.58 % accuracy. The shape sensor uses fiber Bragg grating based optical cable mounted on a micromachined tube and is capable of measuring curvatures as high as 145 /m. These sensors were incorporated and tested in the guidewire and the neuroendoscope tool robots and can provide robust feedback for closed-loop control of these devices in the future.Ph.D

    Image-Guided Robot-Assisted Needle Intervention Devices and Methods to Improve Targeting Accuracy

    Get PDF
    This dissertation addresses the development of medical devices, image-guided robots, and their application in needle-based interventions, as well as methods to improve accuracy and safety in clinical procedures. Needle access is an essential component of minimally invasive diagnostic and therapeutic procedures. Image-guiding devices are often required to help physicians handle the needle based on the images. Integrating robotic accuracy and precision with digital medical imaging has the potential to improve the clinical outcomes. The dissertation presents two robotic devices for interventions under Magnetic Resonance Imaging (MRI) respectively Computed Tomography (CT) – Ultrasound(US) cross modality guidance. The MRI robot is a MR Safe Remote Center of Motion (RCM) robot for direct image-guided needle interventions such as brain surgery. The dissertation also presents the integration of the robot with an intraoperative MRI scanner, and preclinical tests for deep brain needle access. The CT-Ultrasound guidance uses a robotic manipulator to handle an US probe within a CT scanner. The dissertation presents methods related to the co-registration of multi-image spaces with an intermediary frame, experiments for needle targeting. The dissertation also presents method on using optical tracking measurements specifically for medical robots. The method was derived to test the robots presented above. With advanced image-guidance, such as the robotic approaches, needle targeting accuracy may still be deteriorated by errors related to needle defections. Methods and associated devices for needle steering on the straight path are presented. These are a robotic approach that uses real-time ultrasound guidance to steer the needle; Modeling and testing of a method to markedly reduce targeting errors with bevel-point needles; Dynamic design, manufacturing, and testing of a novel core biopsy needle with straighter path, power assistance, reduced noise, and safer operation. Overall, the dissertation presents several developments that contribute to the field of medical devices, image-guided robots, and needle interventions. These include robot testing methods that can be used by other researchers, needle steering methods that can be used directly by physicians or for robotic devices, as well as several methods to improve the accuracy in image-guided interventions. Collectively, these contribute to the field and may have a significant clinical impact

    Agile and Bright Intracardiac Catheters

    Get PDF
    Intracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and therefore they lack novel sensor technology, multi-functionality, and often require manual assembly process. Introduction chapter of this thesis discusses clinical needs and introduces new technological concepts that are needed to progress the functionality and clinical value of the intracardiac catheters along with efficient and simple designs to make the catheters affordable for the patients. The following chapters are grouped into two parts that explore complementary transducer technology and a novel optical fiber-link solution for catheter-based intracardiac imaging. _Part I_ focuses on developing a new intracardiac catheter that has an advanced functionality, which provides clinician with high penetration or close-up high resolution ultrasound imaging in a single device. This agile ultrasound visualization is enabled by a capacitive-micromachined ultrasound transducer (CMUT), operated in collapse-mode, of which the operating frequency can be tuned. Acoustic performance of a fabricated CMUT is modelled and measured. Imaging performance of the CMUT array is quantified on a tissue-mimicking phantom and demonstrated both ex vivo and in vivo experiments. It is found that the combination of the forward-looking design, frequency-tuning and agile deflectability of the catheter allow for visualizing intracardiac structures of various sizes at different distances relative to the catheter tip, providing both wide overviews and detailed close-ups. _Part II_ is devoted to a novel optical technology for transmitting signals and transferring power inside catheters. A novel concept of an all-optical fiber link is introduced. A key insight obtained is that a blue light-emitting diode (LED) may be used as a photo-voltaic converter. Used in reverse under illumination with violet light, it converts significant amount of photonic energy to electricity and at the same time it may emit blue light back, which makes it a unique miniature power and communication channel for catheters. A pressure-sensing catheter prototype is built to demonstrate the concept of transmitting signals and delivering power using a single optical fiber and an LED. The potential of the power and signal fiber link solution is exploited further for ultrasound imaging. A bench-top demonstrator scalable to catheter dimensions is built, in which electrical wires for ultrasound-sensor signal and power tra

    Medical device design within the ISO 13485 framework

    Get PDF
    The design and development of medical devices has become an increasing complex and regulated process. Little if any consideration is given to the regulatory requirements when developing medical devices in universities. This has resulted in an imposing barrier preventing academic innovation reaching clinical adoption. The scope of universities is not to become the legal manufacturer of medical devices. However, should the development of novel devices ever aim to benefit patient care and reach a clinical setting, design controls must be implemented throughout the project life cycle to demonstrate feasibility and safety. The aim of this thesis is to develop user-centred technologies which comply with industrial design control practices whilst helping to bolster and promote innovation within academia. Four projects relating to medical devices have been designed in response to well-defined and end-user-originated clinical needs. These devices can serve as the exemplar for the framework developed in this work with each reaching staggered phases of development within a controlled design process. Although unique, the devices have significant overlapping characteristics that lend the devices to parallel development, leveraging in-house know-how and ‘lessons learned’ into the process of innovation. This thesis focuses on the novelty and design of the aforementioned projects in a discrete structured approach and reflects on the development of each project within the context of a design control process which was developed as part of this work. It is the ultimate goal of this work to develop a flexible structured system compliant with the international requirements for product design and development which may be exported internationally. However, the full execution of this ambition was limited due physical, and financial limitations. This manuscript will describe the technical and commercial opportunity of devices and reflects on the success of developing same within a design control process developed as part of this work

    Haptics: Science, Technology, Applications

    Get PDF
    This open access book constitutes the proceedings of the 12th International Conference on Human Haptic Sensing and Touch Enabled Computer Applications, EuroHaptics 2020, held in Leiden, The Netherlands, in September 2020. The 60 papers presented in this volume were carefully reviewed and selected from 111 submissions. The were organized in topical sections on haptic science, haptic technology, and haptic applications. This year's focus is on accessibility