21,644 research outputs found

    An Improved Approach for Contrast Enhancement of Spinal Cord Images based on Multiscale Retinex Algorithm

    Full text link
    This paper presents a new approach for contrast enhancement of spinal cord medical images based on multirate scheme incorporated into multiscale retinex algorithm. The proposed work here uses HSV color space, since HSV color space separates color details from intensity. The enhancement of medical image is achieved by down sampling the original image into five versions, namely, tiny, small, medium, fine, and normal scale. This is due to the fact that the each versions of the image when independently enhanced and reconstructed results in enormous improvement in the visual quality. Further, the contrast stretching and MultiScale Retinex (MSR) techniques are exploited in order to enhance each of the scaled version of the image. Finally, the enhanced image is obtained by combining each of these scales in an efficient way to obtain the composite enhanced image. The efficiency of the proposed algorithm is validated by using a wavelet energy metric in the wavelet domain. Reconstructed image using proposed method highlights the details (edges and tissues), reduces image noise (Gaussian and Speckle) and improves the overall contrast. The proposed algorithm also enhances sharp edges of the tissue surrounding the spinal cord regions which is useful for diagnosis of spinal cord lesions. Elaborated experiments are conducted on several medical images and results presented show that the enhanced medical pictures are of good quality and is found to be better compared with other researcher methods.Comment: 13 pages, 6 figures, International Journal of Imaging and Robotics. arXiv admin note: text overlap with arXiv:1406.571

    Design of Novel Algorithm and Architecture for Gaussian Based Color Image Enhancement System for Real Time Applications

    Full text link
    This paper presents the development of a new algorithm for Gaussian based color image enhancement system. The algorithm has been designed into architecture suitable for FPGA/ASIC implementation. The color image enhancement is achieved by first convolving an original image with a Gaussian kernel since Gaussian distribution is a point spread function which smoothen the image. Further, logarithm-domain processing and gain/offset corrections are employed in order to enhance and translate pixels into the display range of 0 to 255. The proposed algorithm not only provides better dynamic range compression and color rendition effect but also achieves color constancy in an image. The design exploits high degrees of pipelining and parallel processing to achieve real time performance. The design has been realized by RTL compliant Verilog coding and fits into a single FPGA with a gate count utilization of 321,804. The proposed method is implemented using Xilinx Virtex-II Pro XC2VP40-7FF1148 FPGA device and is capable of processing high resolution color motion pictures of sizes of up to 1600x1200 pixels at the real time video rate of 116 frames per second. This shows that the proposed design would work for not only still images but also for high resolution video sequences.Comment: 15 pages, 15 figure

    Delaunay triangulation based image enhancement for echocardiography images

    Get PDF
    A novel image enhancement approach for automatic echocardiography image processing is proposed. The main steps include undecimated wavelet based speckle noise reduction, edge detection, followed by a regional enhancement process that employs Delaunay triangulation based thresholding. The edge detection is performed using a fuzzy logic based center point detection and a subsequent radial search based fuzzy multiscale edge detection. The edges obtained are used as the vertices for Delaunay triangulation for enhancement purposes. This method enhances the heart wall region in the echo image. This technique is applied to both synthetic and real image sets that were obtained from a local hospital

    Coronal Mass Ejection Detection using Wavelets, Curvelets and Ridgelets: Applications for Space Weather Monitoring

    Full text link
    Coronal mass ejections (CMEs) are large-scale eruptions of plasma and magnetic feld that can produce adverse space weather at Earth and other locations in the Heliosphere. Due to the intrinsic multiscale nature of features in coronagraph images, wavelet and multiscale image processing techniques are well suited to enhancing the visibility of CMEs and supressing noise. However, wavelets are better suited to identifying point-like features, such as noise or background stars, than to enhancing the visibility of the curved form of a typical CME front. Higher order multiscale techniques, such as ridgelets and curvelets, were therefore explored to characterise the morphology (width, curvature) and kinematics (position, velocity, acceleration) of CMEs. Curvelets in particular were found to be well suited to characterising CME properties in a self-consistent manner. Curvelets are thus likely to be of benefit to autonomous monitoring of CME properties for space weather applications.Comment: Accepted for publication in Advances in Space Research (3 April 2010

    CT diagnosis of early stroke : the initial approach to the new CAD tool based on multiscale estimation of ischemia

    Get PDF
    Background: Computer aided diagnosis (CAD) becomes one of the most important diagnostic tools for urgent states in cerebral stroke and other life-threatening conditions where time plays a crucial role. Routine CT is still diagnostically insufficient in hyperacute stage of stroke that is in the therapeutic window for thrombolytic therapy. Authors present computer assistant of early ischemic stroke diagnosis that supports the radiologic interpretations. A new semantic-visualization system of ischemic symptoms applied to noncontrast, routine CT examination was based on multiscale image processing and diagnostic content estimation. Material/Methods: Evaluation of 95 sets of examinations in patients admitted to a hospital with symptoms suggesting stroke was undertaken by four radiologists from two medical centers unaware of the final clinical findings. All of the consecutive cases were considered as having no CT direct signs of hyperacute ischemia. At the first test stage only the CTs performed at the admission were evaluated independently by radiologists. Next, the same early scans were evaluated again with additional use of multiscale computer-assistant of stroke (MulCAS). Computerized suggestion with increased sensitivity to the subtle image manifestations of cerebral ischemia was constructed as additional view representing estimated diagnostic content with enhanced stroke symptoms synchronized to routine CT data preview. Follow-up CT examinations and clinical features confirmed or excluded the diagnosis of stroke constituting 'gold standard' to verify stroke detection performance. Results: Higher AUC (area under curve) values were found for MulCAS -aided radiological diagnosis for all readers and the differences were statistically significant for random readers-random cases parametric and non-parametric DBM MRMC analysis. Sensitivity and specificity of acute stroke detection for the readers was increased by 30% and 4%, respectively. Conclusions: Routine CT completed with proposed method of computer assisted diagnosis provided noticeable better diagnosis efficiency of acute stroke according to the rates and opinions of all test readers. Further research includes fully automatic detection of hypodense regions to complete assisted indications and formulate the suggestions of stroke cases more objectively. Planned prospective studies will let evaluate more accurately the impact of this CAD tool on diagnosis and further treatment in patients suffered from stroke. It is necessary to determine whether this method is possible to be applied widely

    3D Frangi-based lung vessel enhancement filter penalizing airways

    Get PDF
    This paper describes a fully automatic simultaneous lung vessel and airway enhancement filter. The approach consists of a Frangi-based multiscale vessel enhancement filtering specifically designed for lung vessel and airway detection, where arteries and veins have high contrast with respect to the lung parenchyma, and airway walls are hollow tubular structures with a non negative response using the classical Frangi's filter. The features extracted from the Hessian matrix are used to detect centerlines and approximate walls of airways, decreasing the filter response in those areas by applying a penalty function to the vesselness measure. We validate the segmentation method in 20 CT scans with different pathological states within the VESSEL12 challenge framework. Results indicate that our approach obtains good results, decreasing the number of false positives in airway walls
    • …
    corecore