8,488 research outputs found
Gaze-contingent flicker pupil perimetry detects scotomas in patients with cerebral visual impairments or glaucoma
The pupillary light reflex is weaker for stimuli presented inside as compared to outside absolute scotomas. Pupillograph perimetry could thus be an objective measure of impaired visual processing. However, the diagnostic accuracy in detecting scotomas has remained unclear. We quantitatively investigated the accuracy of a novel form of pupil perimetry. The new perimetry method, termed gaze-contingent flicker pupil perimetry, consists of the repetitive on, and off flickering of a bright disk (2 hz; 320 cd/m; 4° diameter) on a gray background (160 cd/m) for 4 seconds per stimulus location. The disk evokes continuous pupil oscillations at the same rate as its flicker frequency, and the oscillatory power of the pupil reflects visual sensitivity. We monocularly presented the disk at a total of 80 locations in the central visual field (max. 15°). The location of the flickering disk moved along with gaze to reduce confounds of eye movements (gaze-contingent paradigm). The test lasted ~5 min per eye and was performed on 7 patients with cerebral visual impairment (CVI), 8 patients with primary open angle glaucoma (age >45), and 14 healthy, age/gender-matched controls. For all patients, pupil oscillation power (FFT based response amplitude to flicker) was significantly weaker when the flickering disk was presented in the impaired as compared to the intact visual field (CVI: 12%, AUC = 0.73; glaucoma: 9%, AUC = 0.63). Differences in power values between impaired and intact visual fields of patients were larger than differences in power values at corresponding locations in the visual fields of the healthy control group (CVI: AUC = 0.95; glaucoma: AUC = 0.87). Pupil sensitivity maps highlighted large field scotomas and indicated the type of visual field defect (VFD) as initially diagnosed with standard automated perimetry (SAP) fairly accurately in CVI patients but less accurately in glaucoma patients. We provide the first quantitative and objective evidence of flicker pupil perimetry's potential in detecting CVI-and glaucoma-induced VFDs. Gaze-contingent flicker pupil perimetry is a useful form of objective perimetry and results suggest it can be used to assess large VFDs with young CVI patients whom are unable to perform SAP
Impaired endothelial function of the retinal vasculature in hypertensive patients
<p><b>Background and Purpose:</b> Arterial hypertension constitutes a central factor in the pathogenesis of stroke. We examined endothelial function of the retinal vasculature as a model of the cerebral circulation.</p>
<p><b>Methods:</b> Thirty-eight young subjects (19 hypertensive and 19 normotensive) were treated with the AT1-receptor blocker candesartan cilexetil and placebo, each over 7 days. Retinal capillary flow and blood flow velocity in the central retinal artery were assessed with scanning laser Doppler flowmetry and pulsed Doppler ultrasound, respectively. NG-monomethyl-L-arginine (L-NMMA) was infused to inhibit nitric oxide (NO) synthesis. Diffuse luminance flicker was applied to stimulate NO release.</p>
<p><b>Results:</b> In normotensive subjects, L-NMMA decreased retinal capillary flow by 8.2%±13% (P<0.05) and flickering light increased mean blood flow velocity in the central retinal artery by 19%±29% (P<0.01). In contrast, no significant change to these provocative tests was seen in hypertensive subjects. Treatment with candesartan cilexetil restored a normal pattern of reactivity in retinal capillaries (L-NMMA: decrease in perfusion by 10%±17%, P<0.05) and the central retinal artery (flicker: increase in mean blood flow velocity by 42%±31%, P<0.001) in hypertensive patients.</p>
<p><b>Conclusions:</b> Endothelial function of the retinal vasculature is impaired in early essential hypertension but can be improved by AT1-receptor blockade.</p>
Engineering data compendium. Human perception and performance. User's guide
The concept underlying the Engineering Data Compendium was the product of a research and development program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design and military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from the existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by systems designers. The present four volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is the first volume, the User's Guide, containing a description of the program and instructions for its use
The Use of a Visual Testing Apparatus for Space Application Final Report
Support services for calibration and development of optimum utilization plans for visual parameter tester applicable to manned space fligh
Characteristics of flight simulator visual systems
The physical parameters of the flight simulator visual system that characterize the system and determine its fidelity are identified and defined. The characteristics of visual simulation systems are discussed in terms of the basic categories of spatial, energy, and temporal properties corresponding to the three fundamental quantities of length, mass, and time. Each of these parameters are further addressed in relation to its effect, its appropriate units or descriptors, methods of measurement, and its use or importance to image quality
Recommended from our members
Macular Pigment and Visual Function in Patients With Glaucoma: The San Diego Macular Pigment Study.
PurposeAlthough recent studies have shown that macular pigment (MP) is significantly lower in glaucoma patients, this relationship merits further investigation.MethodsThis cross-sectional study included 85 glaucoma patients and 22 controls. All subjects had standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements. Intake of lutein (L) and zeaxanthin (Z) was estimated using a novel dietary screener. The Heidelberg Spectralis dual-wavelength autofluorescence (AF) technology was employed to study the relationship between MP and glaucoma. The association between MP volume and glaucoma was investigated using linear regression models accounting for potential confounding factors.ResultsGlaucoma patients had significantly worse SAP mean deviation (MD) and lower RNFL thickness in the study eye compared to control subjects (P < 0.001 for both). MP (volume) was comparable between groups (P = 0.436). In the univariable model, diagnosis of glaucoma was not associated with MP volume (R2 = 1.22%; P = 0.257). Dietary intake of L and Z was positively and significantly related to MP in the univariable (P = 0.022) and multivariable (P = 0.020) models.ConclusionsThese results challenge previous studies that reported that glaucoma is associated with low MP. Dietary habits were found to be the main predictor of MP in this sample. Further research is merited to better understand the relationship between glaucoma, MP, and visual performance in these patients
Exposure of man to low intensity magnetic fields in a coil system
Physiological and psychological effects of prolonged exposure to low intensity magnetic field
Recommended from our members
Changes in forward light scatter parameters as a function of refractive error in young adults
Background/aims
Some aspects of visual performance worsen with increasing myopia. Whilst the underlying causes are not always clear, reduction in retinal image quality is often attributed to structural changes in the posterior myopic eye. Forward light scatter, originating principally from the cornea and lens, is known to produce veiling glare which subsequently reduces retinal image contrast. It is therefore of interest to investigate whether forward light scatter varies with refractive error.
Methods
Thirteen young-adult subjects (18–25 years), with mean spherical errors (MSE ± sd, D) RE, − 1.69 ± 2.02 (range 0.38 to − 4.75); LE, − 1.91 ± 1.94 (range 0.50 to − 4.63) underwent binocular assessment of forward light scatter using the AVOT light scatter test. Five glare annuli, with effective eccentricities ranging from 2 to 10°, were used to estimate parameters, k and n, which define the light scatter function of the eye. These were then used to calculate the area under the light scatter function (k′) and the total volume of light scatter (k″).
Results
Significant correlation was found between increasing myopia and k′ values (RE, p  0.05 for both eyes). Axial length was also not correlated with any of the light scatter parameters measured.
Conclusion
The preliminary data from this study provide evidence that some light scatter parameters may be correlated with refractive error. Further studies are needed to characterize how changes in the anterior media of the eye, and inclusion of a wider range of refractive errors, may affect forward light scatter
P31 phosphor persistence at photopic mean luminance level.
P31 phosphor screens are frequently used for short-term presentation of dot and grating patterns, but experimental data obtained with this technique have been criticized because of possible parasitic effects of phosphor persistence on subjects' visual performance. Recently, this issue provoked a controversial discussion in Vision Research (Groner et al., 1993; Westheimer, 1993, 1994; Irwin, 1994; Di Lollo et al., 1994) which was concerned with persistence effects of P31 screens for dot patterns. Supplementing this discussion, the present work deals with the effects of different types of patterns (dot pattern vs. gratings) and background mean-luminance levels (scotopic vs. phototopic) on phosphor persistence. Physical measurements of P31 persistence occurring with grating patterns of a mean luminance of 20 cd m-2 (i.e. photopic range) were obtained by using an extremely linear photometer with high temporal resolution. Under this photopic condition, the measurements demonstrate a fast decay of residual grating contrast to 1.4% of its original value within 50 ms after pattern offset. This phosphor behavior must be considered when designing an experiment with a P31 screen though it certainly embodies no problems in many applications
Recommended from our members
An Evaluation of a Battery of Functional and Structural Tests as Predictors of Likely Risk of Progression of Age-Related Macular Degeneration.
Purpose: To evaluate the ability of visual function and structural tests to identify the likely risk of progression from early/intermediate to advanced AMD, using the Age-Related Eye Disease Study (AREDS) simplified scale as a surrogate for risk of progression. The secondary aim was to determine the relationship between disease severity grade and the observed functional and structural deficits. Methods: A total of 100 participants whose AMD status varied from early to advanced were recruited. Visual function was assessed using cone dark adaptation, 14 Hz flicker and chromatic threshold tests and retinal structure was assessed by measuring drusen volume and macular thickness. The predictive value of the tests was estimated using ordinal regression analysis. Group comparisons were assessed using analysis of covariance. Results: Change in cone dark adaptation (cone Ï„) and yellow-blue (YB) chromatic sensitivity were independent predictors for AMD progression risk (cone Ï„, pseudo R2 = 0.35, P < 0.001; YB chromatic threshold, pseudo R2 = 0.16, P < 0.001). The only structural predictor was foveal thickness (R2 = 0.05, P = 0.047). Chromatic sensitivity and cone dark adaptation were also the best functional tests at distinguishing between severity groups. Drusen characteristics clearly differentiated between participants with early and advanced disease, but were not able to differentiate between those with early AMD and controls. Mean differences in retinal thickness existed between severity groups at the foveal (P = 0.040) and inner (P = 0.001) subfields. Conclusions: This study indicates that cone Ï„, YB chromatic threshold and foveal thickness are independent predictors of likely risk of AMD progression
- …