86 research outputs found

    Noncontact Vital Signs Detection

    Get PDF
    Human health condition can be accessed by measurement of vital signs, i.e., respiratory rate (RR), heart rate (HR), blood oxygen level, temperature and blood pressure. Due to drawbacks of contact sensors in measurement, non-contact sensors such as imaging photoplethysmogram (IPPG) and Doppler radar system have been proposed for cardiorespiratory rates detection by researchers.The UWB pulse Doppler radars provide high resolution range-time-frequency information. It is bestowed with advantages of low transmitted power, through-wall capabilities, and high resolution in localization. However, the poor signal to noise ratio (SNR) makes it challenging for UWB radar systems to accurately detect the heartbeat of a subject. To solve the problem, phased-methods have been proposed to extract the phase variations in the reflected pulses modulated by human tiny thorax motions. Advance signal processing method, i.e., state space method, can not only be used to enhance SNR of human vital signs detection, but also enable the micro-Doppler trajectories extraction of walking subject from UWB radar data.Stepped Frequency Continuous Wave (SFCW) radar is an alternative technique useful to remotely monitor human subject activities. Compared with UWB pulse radar, it relieves the stress on requirement of high sampling rate analog-to-digital converter (ADC) and possesses higher signal-to-noise-ratio (SNR) in vital signs detection. However, conventional SFCW radar suffers from long data acquisition time to step over many frequencies. To solve this problem, multi-channel SFCW radar has been proposed to step through different frequency bandwidths simultaneously. Compressed sensing (CS) can further reduce the data acquisition time by randomly stepping through 20% of the original frequency steps.In this work, SFCW system is implemented with low cost, off-the-shelf surface mount components to make the radar sensors portable. Experimental results collected from both pulse and SFCW radar systems have been validated with commercial contact sensors and satisfactory results are shown

    A Photoplethysmography System Optimised for Pervasive Cardiac Monitoring

    Get PDF
    Photoplethysmography is a non-invasive sensing technique which infers instantaneous cardiac function from an optical measurement of blood vessels. This thesis presents a photoplethysmography based sensor system that has been developed speci fically for the requirements of a pervasive healthcare monitoring system. Continuous monitoring of patients requires both the size and power consumption of the chosen sensor solution to be minimised to ensure the patients will be willing to use the device. Pervasive sensing also requires that the device be scalable for manufacturing in high volume at a build cost that healthcare providers are willing to accept. System level choice of both electronic circuits and signal processing techniques are based on their sensitivity to cardiac biosignals, robustness against noise inducing artefacts and simplicity of implementation. Numerical analysis is used to justify the implementation of a technique in hardware. Circuit prototyping and experimental data collection is used to validate a technique's application. The entire signal chain operates in the discrete-time domain which allows all of the signal processing to be implemented in firmware on an embedded processor which minimised the number of discrete components while optimising the trade-off between power and bandwidth in the analogue front-end. Synchronisation of the optical illumination and detection modules enables high dynamic range rejection of both AC and DC independent light sources without compromising the biosignal. Signal delineation is used to reduce the required communication bandwidth as it preserves both amplitude and temporal resolution of the non-stationary photoplethysmography signals allowing more complicated analytical techniques to be performed at the other end of communication channel. The complete sensing system is implemented on a single PCB using only commercial-off -the-shelf components and consumes less than 7.5mW of power. The sensor platform is validated by the successful capture of physiological data in a harsh optical sensing environment

    A Photoplethysmography System Optimised for Pervasive Cardiac Monitoring

    No full text
    Photoplethysmography is a non-invasive sensing technique which infers instantaneous cardiac function from an optical measurement of blood vessels. This thesis presents a photoplethysmography based sensor system that has been developed speci fically for the requirements of a pervasive healthcare monitoring system. Continuous monitoring of patients requires both the size and power consumption of the chosen sensor solution to be minimised to ensure the patients will be willing to use the device. Pervasive sensing also requires that the device be scalable for manufacturing in high volume at a build cost that healthcare providers are willing to accept. System level choice of both electronic circuits and signal processing techniques are based on their sensitivity to cardiac biosignals, robustness against noise inducing artefacts and simplicity of implementation. Numerical analysis is used to justify the implementation of a technique in hardware. Circuit prototyping and experimental data collection is used to validate a technique's application. The entire signal chain operates in the discrete-time domain which allows all of the signal processing to be implemented in firmware on an embedded processor which minimised the number of discrete components while optimising the trade-off between power and bandwidth in the analogue front-end. Synchronisation of the optical illumination and detection modules enables high dynamic range rejection of both AC and DC independent light sources without compromising the biosignal. Signal delineation is used to reduce the required communication bandwidth as it preserves both amplitude and temporal resolution of the non-stationary photoplethysmography signals allowing more complicated analytical techniques to be performed at the other end of communication channel. The complete sensing system is implemented on a single PCB using only commercial-off -the-shelf components and consumes less than 7.5mW of power. The sensor platform is validated by the successful capture of physiological data in a harsh optical sensing environment

    Frame registration for motion compensation in imaging photoplethysmography

    Get PDF
    © 2018 by the authors. Licensee MDPI, Basel, Switzerland. Imaging photoplethysmography (iPPG) is an emerging technology used to assess microcirculation and cardiovascular signs by collecting backscattered light from illuminated tissue using optical imaging sensors. An engineering approach is used to evaluate whether a silicone cast of a human palm might be effectively utilized to predict the results of image registration schemes for motion compensation prior to their application on live human tissue. This allows us to establish a performance baseline for each of the algorithms and to isolate performance and noise fluctuations due to the induced motion from the temporally changing physiological signs. A multi-stage evaluation model is developed to qualitatively assess the influence of the region of interest (ROI), system resolution and distance, reference frame selection, and signal normalization on extracted iPPG waveforms from live tissue. We conclude that the application of image registration is able to deliver up to 75% signal-to-noise (SNR) improvement (4.75 to 8.34) over an uncompensated iPPG signal by employing an intensity-based algorithm with a moving reference frame

    Data Acquisition Applications

    Get PDF
    Data acquisition systems have numerous applications. This book has a total of 13 chapters and is divided into three sections: Industrial applications, Medical applications and Scientific experiments. The chapters are written by experts from around the world, while the targeted audience for this book includes professionals who are designers or researchers in the field of data acquisition systems. Faculty members and graduate students could also benefit from the book

    Q-PPG: Energy-Efficient PPG-Based Heart Rate Monitoring on Wearable Devices

    Get PDF
    Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices.In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single "seed" model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE < 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference

    Wearable Sensors and Smart Devices to Monitor Rehabilitation Parameters and Sports Performance: An Overview

    Get PDF
    A quantitative evaluation of kinetic parameters, the joint’s range of motion, heart rate, and breathing rate, can be employed in sports performance tracking and rehabilitation monitoring following injuries or surgical operations. However, many of the current detection systems are expensive and designed for clinical use, requiring the presence of a physician and medical staff to assist users in the device’s positioning and measurements. The goal of wearable sensors is to overcome the limitations of current devices, enabling the acquisition of a user’s vital signs directly from the body in an accurate and non–invasive way. In sports activities, wearable sensors allow athletes to monitor performance and body movements objectively, going beyond the coach’s subjective evaluation limits. The main goal of this review paper is to provide a comprehensive overview of wearable technologies and sensing systems to detect and monitor the physiological parameters of patients during post–operative rehabilitation and athletes’ training, and to present evidence that supports the efficacy of this technology for healthcare applications. First, a classification of the human physiological parameters acquired from the human body by sensors attached to sensitive skin locations or worn as a part of garments is introduced, carrying important feedback on the user’s health status. Then, a detailed description of the electromechanical transduction mechanisms allows a comparison of the technologies used in wearable applications to monitor sports and rehabilitation activities. This paves the way for an analysis of wearable technologies, providing a comprehensive comparison of the current state of the art of available sensors and systems. Comparative and statistical analyses are provided to point out useful insights for defining the best technologies and solutions for monitoring body movements. Lastly, the presented review is compared with similar ones reported in the literature to highlight its strengths and novelties

    Ultra Low Energy Communication Protocol for Implantable Wireless Body Sensor Networks

    Get PDF
    Abstract Title: Ultra Low Energy Communication Protocol for Implantable Wireless Body Sensor Networks. Fariborz Fereydouni_Forouzandeh, Ph.D. Concordia University, 2010 Medical science will soon start to benefit from wireless communication and implantable sensor technologies being developed for use in the human body. Such technologies have a potential to revolutionize the health-care industry by providing real-time patient monitoring capabilities to the health-care professionals. In this regard, implantable wireless body sensor networks (IWBSNs) have recently emerged as an important and growing area of research. The implantable sensors are required to be reliable and very small so that the body does not reject them. They must stay functional in the human body for years, and most importantly, they must not be a source of discomfort to the potential patients. The life time of their embedded batteries could vary from a few days to a few weeks using current hardware and software technologies. In order to make such devices suitable for implantation an order of magnitude reduction in energy use is required. Our research is motivated by this goal. In this thesis, we identify and analyze the sources of energy use in typical devices meant for Implantation in a human body. Our detailed mathematical analysis and computer simulations clearly demonstrate that improving the efficiency of communication protocols is the only realistic way of achieving this goal. Unfortunately, none of the existing low range low energy wireless communication protocols can be used in IWBSNs because of the small energy resources available in the implanted sensor nodes. We propose a new energy aware communication protocol which efficiently encodes data in time domain. It ensures accurate transmission of information. The encoding scheme does this by sending only a single signal from the sensor node to the base station. The protocol is called the Time Based Coded Data protocol or TBCD in short. For proper operation of this protocol reliable synchronization is required. Our proposed synchronization algorithm is energy efficient and stable under worst case conditions as compared to existing algorithms. A sensor node using existing state of the art technology that can only last for a few weeks can be made to last for few years using our proposed communication protocol and the synchronization algorithm
    corecore