9,747 research outputs found

    Mechanical work performed by individual limbs of transfemoral amputees during step-to-step transitions: Effect of walking velocity

    Get PDF
    The greater metabolic demand during the gait of people with a transfemoral amputation limits their autonomy and walking velocity. Major modifications of the kinematic and kinetic patterns of transfemoral amputee gait quantified using gait analysis may explain their greater energy cost. Donelan et al. proposed a method called the individual limb method to explore the relationships between the gait biomechanics and metabolic cost. In the present study, we applied this method to quantify mechanical work performed by the affected and intact limbs of transfemoral amputees. We compared a cohort of six active unilateral transfemoral amputees to a control group of six asymptomatic subjects. Compared to the control group, we found that there was significantly less mechanical work produced by the affected leg and significantly more work performed by the unaffected leg during the step-to-step transition. We also found that this mechanical work increased with walking velocity; the increase was less pronounced for the affected leg and substantial for the unaffected leg. Finally, we observed that the lesser work produced by the affected leg was linked to the increase in the hip flexion moment during the late stance phase, which is necessary for initiating knee flexion in the affected leg. It is possible to quantify the mechanical work performed during gait by people with a transfemoral amputation, using the individual limb method and conventional gait laboratory equipment. The method provides information that is useful for prosthetic fitting and rehabilitation

    Vaulting quantification during level walking of transfemoral amputees

    Get PDF
    Background: Vaulting is a gait compensatory mechanism used by transfemoral amputees to assist toe clearance during the prosthetic swing phase. It is defined by a plantar flexion of the contralateral ankle during the single-limb support phase. The aim of the study is to propose a method to quantify vaulting of transfemoral amputees. Methods: 17 transfemoral amputees and 28 asymptomatic subjects participated in the data collection. Kinematics and kinetics of thewhole bodywere recordedwhile subjectswerewalking on a level surface. Biomechanical gait analysis was focused on a reduced set of parameters linked to the contralateral ankle, the contralateral knee and the trajectory of the center of pressure. The patients were classified in two groups: with orwithout vaulting using video recordings. Differences between both groups and the control group were analyzed. Findings: A higher generated ankle powerwas found during the single support phase of the contralateral limb of transfemoralamputees presenting vaulting. These subjects presented also a higher dissipated knee flexion power before the peak in ankle flexion power. The trajectory of the center of pressurewas also modified by the vaulting. Interpretation: Vaulting for transfemoral amputees is characterized by a propulsive plantar flexion at the contralateral ankle. Quantifying the ankle flexion power during the contralateral single support phase will help in understanding vaulting.This study was supported by the French National Research Agency, under reference ANR-2010-TECS-020. The authors are deeply grateful to F. Lavaste, N. Martinet, J. Paysant, and N. Rapin for their contribution to the study

    Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

    Get PDF
    Background and purposeRehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling.Methods51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant.ResultsAt 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up.InterpretationThe RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations

    Ability of modal analysis to detect osseointegration of implants in transfemoral amputees : a physical model study

    Get PDF
    Owing to the successful use of non-invasive vibration analysis to monitor the progression of dental implant healing and stabilization, it is now being considered as a method to monitor femoral implants in transfemoral amputees. This study uses composite femur-implant physical models to investigate the ability of modal analysis to detect changes at the interface between the implant and bone simulating those that occur during osseointegration. Using electromagnetic shaker excitation, differences were detected in the resonant frequencies and mode shapes of the model when the implant fit in the bone was altered to simulate the two interface cases considered: firm and loose fixation. The study showed that it is beneficial to examine higher resonant frequencies and their mode shapes (rather than the fundamental frequency only) when assessing fixation. The influence of the model boundary conditions on the modal parameters was also demonstrated. Further work is required to more accurately model the mechanical changes occurring at the bone-implant interface in vivo, as well as further refinement of the model boundary conditions to appropriately represent the in vivo conditions. Nevertheless the ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation

    Improved costs and outcomes with conscious sedation vs general anesthesia in TAVR patients: Time to wake up?

    Get PDF
    BackgroundTranscatheter aortic valve replacement (TAVR) has become a commonplace procedure for the treatment of aortic stenosis in higher risk surgical patients. With the high cost and steadily increasing number of patients receiving TAVR, emphasis has been placed on optimizing outcomes as well as resource utilization. Recently, studies have demonstrated the feasibility of conscious sedation in lieu of general anesthesia for TAVR. This study aimed to investigate the clinical as well as cost outcomes associated with conscious sedation in comparison to general anesthesia in TAVR.MethodsRecords for all adult patients undergoing TAVR at our institution between August 2012 and June 2016 were included using our institutional Society of Thoracic Surgeons (STS) and American College of Cardiology (ACC) registries. Cost data was gathered using the BIOME database. Patients were stratified into two groups according to whether they received general anesthesia (GA) or conscious sedation (CS) during the procedure. No-replacement propensity score matching was done using the validated STS predicted risk of mortality (PROM) as a propensity score. Primary outcome measure with survival to discharge and several secondary outcome measures were also included in analysis. According to our institution's data reporting guidelines, all cost data is presented as a percentage of the general anesthesia control group cost.ResultsOf the 231 patients initially identified, 225 (157 GA, 68 CS) were included for analysis. After no-replacement propensity score matching, 196 patients (147 GA, 49 CS) remained. Overall mortality was 1.5% in the matched population with a trend towards lower mortality in the CS group. Conscious sedation was associated with significantly fewer ICU hours (30 vs 96 hours, p = <0.001) and total hospital days (4.9 vs 10.4, p<0.001). Additionally, there was a 28% decrease in direct cost (p<0.001) as well as significant decreases in all individual all cost categories associated with the use of conscious sedation. There was no difference in composite major adverse events between groups. These trends remained on all subsequent subgroup analyses.ConclusionConscious sedation is emerging as a safe and viable option for anesthesia in patients undergoing transcatheter aortic valve replacement. The use of conscious sedation was not only associated with similar rates of adverse events, but also shortened ICU and overall hospital stays. Finally, there were significant decreases in all cost categories when compared to a propensity matched cohort receiving general anesthesia

    Osseointegrated prostheses for rehabilitation following amputation : The pioneering Swedish model.

    Get PDF
    The direct attachment of osseointegrated (OI) prostheses to the skeleton avoids the inherent problems of socket suspension. It also provides physiological weight bearing, improved range of motion in the proximal joint, as well as osseoperceptive sensory feedback, enabling better control of the artificial limbs by amputees. The present article briefly reviews the pioneering efforts on extremity osseointegration surgeries in Sweden and the development of the OPRA (Osseointegrated Prostheses for the Rehabilitation of Amputees) program. The standard implant design of the OPRA system and surgical techniques are described as well as the special rehabilitation protocols based on surgical sites. The results of long-term follow-up for transradial, transhumeral, and thumb amputee operations are briefly reported including the prospective study of transfemoral amputees according to OPRA protocol. The importance of refinement on implant designs and surgical techniques based on the biomechanical analysis and early clinical trials is emphasized. Future aspects on osseointegration surgery are briefly described, including novel treatment options using implanted electrodes

    Elective percutaneous coronary intervention in the elderly patient

    Get PDF
    Elderly patients account for an increasing number and proportion of patients requiring management of coronary artery disease. Whilst medical therapy remains the cornerstone of management, percutaneous coronary intervention (PCI) has been shown to improve symptoms of angina and quality of life in elderly patients. PCI is now a routine treatment for both acute and chronic coronary artery disease. In the last decade, a series of technological and therapeutic developments have reduced in-hospital complications following PCI. The transradial approach is associated with fewer vascular complications, reduced bed utilization and reduced time to ambulation. This has facilitated the introduction and expansion of outpatient PCI, which has been shown to be safe and effective in elderly patients. This article reviews the rationale for outpatient PCI in the elderly and the evidence for its effectiveness and safety
    corecore