51 research outputs found

    Texture Determination from Ultrasonic Wave Speeds for Hexagonal Close Pack and Cubic Materials

    Get PDF
    Crystallographic texture in polycrystalline hexagonal close pack (HCP) and cubic materials, often developed during thermomechanical deformations, has profound effects on properties at the macroscopic or component level. In this talk, a novel theoretical convolution model is presented, which couples the single crystal wave speed (the kernel function) with the polycrystal crystallographic orientation distribution function to give the resultant polycrystal wave speed function. Firstly developed on HCP [1] and then successfully extended to general anisotropic materials [2], the theoretical model expresses the three functions as harmonic expansions, thus enabling the calculation of any one of them when the other two are known. Hence, the forward problem of determination of polycrystal wave speed is solved for all crystal systems. Verifications are provided on various textures, showing near-perfect representation of the sensitivity of wave speed to texture as well as quantitative predictions of polycrystal wave speed. More importantly, the model also presents a solution to the long-standing inverse problem of detecting texture using ultrasound, with proof of principle established where the wave velocities propagating in groups of HCP and cubic polycrystals with different known textures are computationally calculated, and then the texture information is recovered solely from simulated velocities through the model, and the results show good agreements with the original textures. With possibilities of developing a powerful tool for bulk texture measurement and wave propagation studies in general for HCP, cubic materials now shown, further experimental validations of the proposed model are then conducted. A series of samples cut from typical HCP and cubic materials, including commercially pure (CP) Ti, copper, Ti-6Al-4V, are examined by carefully designed experimental setup for the measurement of the angular variations of ultrasonic wave velocities. Texture information of the samples are extracted out from these measured velocities using the model, for the comparison and calibration against the set of information of the same samples measured independently by the well-established neutron diffraction technique. This part of the research is still ongoing and we hope to be able to show results soon

    Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images

    Get PDF
    Spatial encoding in MR techniques is achieved by sampling the signal as a function of time in the presence of a magnetic field gradient. The gradients are assumed to generate 6 linear magnetic field gradient, and typical image reconstruction relies upon this approximation. However, high-speed gradients in the current generation of MRI scanners often sacrifice linearity for improvements in speed. Such nonlinearity results in distorted images. The problem is presented in terms of first principles and a correction method based on a gradient field spherical harmonic expansion is proposed. In our case, the amount of distortion measured within a typical field of view (FOV) required for head imaging is sufficiently large that without the use of some distortion correction technique, the images would be of limited use for stereotaxy or longitudinal studies, where precise volumetric information is required. (C) 2004 Wiley-Liss, Inc

    A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data

    Get PDF
    Diffusion weighted ( DW ) MRI facilitates non-invasive quantification of tissue microstructure and, in combination with appropriate signal processing, three-dimensional estimates of fibrous orientation. In recent years, attention has shifted from the diffusion tensor model, which assumes a unimodal Gaussian diffusion displacement profile to recover fibre orientation ( with various well-documented limitations ), towards more complex high angular resolution diffusion imaging ( HARDI ) analysis techniques. Spherical deconvolution ( SD ) approaches assume that the fibre orientation density function ( fODF ) within a voxel can be obtained by deconvolving a ‘common’ single fibre response function from the observed set of DW signals. In practice, this common response function is not known a priori and thus an estimated fibre response must be used. Here the establishment of this single-fibre response function is referred to as ‘calibration’. This work examines the vulnerability of two different SD approaches to inappropriate response function calibration: ( 1 ) constrained spherical harmonic deconvolution ( CSHD )—a technique that exploits spherical harmonic basis sets and ( 2 ) damped Richardson–Lucy ( dRL ) deconvolution—a technique based on the standard Richardson–Lucy deconvolution. Through simulations, the impact of a discrepancy between the calibrated diffusion profiles and the observed ( ‘Target’ ) DW-signals in both single and crossing-fibre configurations was investigated. The results show that CSHD produces spurious fODF peaks ( consistent with well known ringing artefacts ) as the discrepancy between calibration and target response increases, while dRL demonstrates a lower over-all sensitivity to miscalibration ( with a calibration response function for a highly anisotropic fibre being optimal ). However, dRL demonstrates a reduced ability to resolve low anisotropy crossing-fibres compared to CSHD. It is concluded that the range and spatial-distribution of expected single-fibre anisotropies within an image must be carefully considered to ensure selection of the appropriate algorithm, parameters and calibration. Failure to choose the calibration response function carefully may severely impact the quality of any resultant tractography

    Distinct subdivisions of the cingulum bundle revealed by diffusion MRI fibre tracking: Implications for neuropsychological investigations

    Get PDF
    The cingulum is a prominent white matter tract that supports prefrontal, parietal, and temporal lobe interactions. Despite being composed of both short and long association fibres, many MRI-based reconstructions ( tractography ) of the cingulum depict an essentially uniform tract that almost encircles the corpus callosum. The present study tested the validity of dividing this tract into subdivisions corresponding to the ‘parahippocampal’, ‘retrosplenial’, and ‘subgenual’ portions of the cingulum. These three cingulum subdivisions occupied different medial–lateral locations, producing a topographic arrangement of cingulum fibres. Other comparisons based on these different reconstructions indicate that only a small proportion of the total white matter in the cingulum traverses the length of the tract. In addition, both the radial diffusivity and fractional anisotropy of the subgenual subdivision differed from that of the retrosplenial subdivision which, in turn, differed from that of the parahippocampal subdivision. The extent to which the radial diffusivity scores and the fractional anisotropy scores correlated between the various cingulum subdivisions proved variable, illustrating how one subdivision may not act as a proxy for other cingulum subdivisions. Attempts to relate the status of the cingulum, as measured by MRI-based fibre tracking, with cognitive or affective measures will, therefore, depend greatly on how and where the cingulum is reconstructed. The present study provides a new framework for subdividing the cingulum, based both on its known connectivity and MRI-based properties

    A method for improving the performance of gradient systems for diffusion-weighted MRI

    Get PDF
    The MR signal is sensitive to diffusion. This effect can be increased by the use of large, balanced bipolar gradients. The gradient systems of MR scanners are calibrated at installation and during regular servicing visits. Because the measured apparent diffusion constant (ADC) depends on the square of the amplitude of the diffusion sensitizing gradients, errors in the gradient calibration are exaggerated. If the error is varying among the different gradient axes, it will affect the estimated degree of anisotropy. To assess the gradient calibration accuracy in a whole-body MRI scanner, ADC values were calculated for a uniform water phantom along each gradient direction while monitoring the temperature. Knowledge of the temperature allows the expected diffusion constant of water to be calculated independent of the MRI measurement. It was found that the gradient axes (±x, ±y, ±z) were calibrated differently, resulting in offset ADC values. A method is presented to rescale the amplitude of each of the six principal gradient axes within the MR pulse sequence. The scaling factor is the square root of the ratio of the expected and observed diffusion constants. In addition, fiber tracking results in the human brain were noticeably affected by improving the gradient system calibration. Magn Reson Med 58:763–768, 2007. © 2007 Wiley-Liss, Inc

    Tractography in the presence of multiple sclerosis lesions

    Get PDF
    Accurate anatomical localisation of specific white matter tracts and the quantification of their tract-specific microstructural damage in conditions such as multiple sclerosis (MS) can contribute to a better understanding of symptomatology, disease evolution and intervention effects. Diffusion MRI-based tractography is being used increasingly to segment white matter tracts as regions-of-interest for subsequent quantitative analysis. Since MS lesions can interrupt the tractography algorithm’s tract reconstruction, clinical studies frequently resort to atlas-based approaches, which are convenient but ignorant to individual variability in tract size and shape. Here, we revisit the problem of individual tractography in MS, comparing tractography algorithms using: (i) The diffusion tensor framework; (ii) constrained spherical deconvolution (CSD); and (iii) damped Richardson-Lucy (dRL) deconvolution. Firstly, using simulated and in vivo data from 29 MS patients and 19 healthy controls, we show that the three tracking algorithms respond differentially to MS pathology. While the tensor-based approach is unable to deal with crossing fibres, CSD produces spurious streamlines, in particular in tissue with high fibre loss and low diffusion anisotropy. With dRL, streamlines are increasingly interrupted in pathological tissue. Secondly, we demonstrate that despite the effects of lesions on the fibre orientation reconstruction algorithms, fibre tracking algorithms are still able to segment tracts that pass through areas with a high prevalence of lesions. Combining dRL-based tractography with an automated tract segmentation tool on data from 131 MS patients, the cortico-spinal tracts and arcuate fasciculi could be reconstructed in more than 90% of individuals. Comparing tract-specific microstructural parameters (fractional anisotropy, radial diffusivity and magnetisation transfer ratio) in individually segmented tracts to those from a tract probability map, we show that there is no systematic disease-related bias in the individually reconstructed tracts, suggesting that lesions and otherwise damaged parts are not systematically omitted during tractography. Thirdly, we demonstrate modest anatomical correspondence between the individual and tract probability-based approach, with a spatial overlap between 35 and 55%. Correlations between tract-averaged microstructural parameters in individually segmented tracts and the probability-map approach ranged between r=.53 ( p<.001 ) for radial diffusivity in the right cortico-spinal tract and r=.97 ( p<.001 ) for magnetisation transfer ratio in the arcuate fasciculi. Our results show that MS white matter lesions impact fibre orientation reconstructions but this does not appear to hinder the ability to anatomically reconstruct white matter tracts in MS. Individual tract segmentation in MS is feasible on a large scale and could prove a powerful tool for investigating diagnostic and prognostic markers

    Three-Dimensional Variable Slab-Selective Projection Acquisition Imaging

    Full text link
    Three-dimensional (3D) projection acquisition (PA) imaging has recently gained attention because of its advantages, such as achievability of very short echo time, less sensitivity to motion, and undersampled acquisition of projections without sacrificing spatial resolution. However, larger subjects require a stronger Nyquist criterion and are more likely to be affected by outer-volume signals outside the field of view (FOV), which significantly degrades the image quality. Here, we proposed a variable slab-selective projection acquisition (VSS-PA) method to mitigate the Nyquist criterion and effectively suppress aliasing streak artifacts in 3D PA imaging. The proposed method involves maintaining the vertical orientation of the slab-selective gradient for frequency-selective spin excitation and the readout gradient for data acquisition. As VSS-PA can selectively excite spins only in the width of the desired FOV in the projection direction during data acquisition, the effective size of the scanned object that determines the Nyquist criterion can be reduced. Additionally, unwanted signals originating from outside the FOV (e.g., aliasing streak artifacts) can be effectively avoided. The mitigation of the Nyquist criterion owing to VSS-PA was theoretically described and confirmed through numerical simulations and phantom and human lung experiments. These experiments further showed that the aliasing streak artifacts were nearly suppressed.Comment: 9 Pages, 6 figures, 28 referenc

    Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the present work we compared the spatial uncertainties associated with a MR-based workflow for external radiotherapy of prostate cancer to a standard CT-based workflow. The MR-based workflow relies on target definition and patient positioning based on MR imaging. A solution for patient transport between the MR scanner and the treatment units has been developed. For the CT-based workflow, the target is defined on a MR series but then transferred to a CT study through image registration before treatment planning, and a patient positioning using portal imaging and fiducial markers.</p> <p>Methods</p> <p>An "open bore" 1.5T MRI scanner, Siemens Espree, has been installed in the radiotherapy department in near proximity to a treatment unit to enable patient transport between the two installations, and hence use the MRI for patient positioning. The spatial uncertainty caused by the transport was added to the uncertainty originating from the target definition process, estimated through a review of the scientific literature. The uncertainty in the CT-based workflow was estimated through a literature review.</p> <p>Results</p> <p>The systematic uncertainties, affecting all treatment fractions, are reduced from 3-4 mm (1Sd) with a CT based workflow to 2-3 mm with a MR based workflow. The main contributing factor to this improvement is the exclusion of registration between MR and CT in the planning phase of the treatment.</p> <p>Conclusion</p> <p>Treatment planning directly on MR images reduce the spatial uncertainty for prostate treatments.</p

    Why diffusion tensor MRI does well only some of the time: Variance and covariance of white matter tissue microstructure attributes in the living human brain

    Get PDF
    Fundamental to increasing our understanding of the role of white matter microstructure in normal/abnormal function in the living human is the development of MR-based metrics that provide increased specificity to distinct attributes of the white matter (e.g., local fibre architecture, axon morphology, and myelin content). In recent years, different approaches have been developed to enhance this specificity, and the Tractometry framework was introduced to combine the resulting multi-parametric data for a comprehensive assessment of white matter properties. The present work exploits that framework to characterise the statistical properties, specifically the variance and covariance, of these advanced microstructural indices across the major white matter pathways, with the aim of giving clear indications on the preferred metric(s) given the specific research question. A cohort of healthy subjects was scanned with a protocol that combined multi-component relaxometry with conventional and advanced diffusion MRI acquisitions to build the first comprehensive MRI atlas of white matter microstructure. The mean and standard deviation of the different metrics were analysed in order to understand how they vary across different brain regions/individuals and the correlation between them. Characterising the fibre architectural complexity (in terms of number of fibre populations in a voxel) provides clear insights into correlation/lack of correlation between the different metrics and explains why DT-MRI is a good model for white matter only some of the time. The study also identifies the metrics that account for the largest inter-subject variability and reports the minimal sample size required to detect differences in means, showing that, on the other hand, conventional DT-MRI indices might still be the safest choice in many contexts
    • 