721 research outputs found

    Hydraulic switch for dishwashers with bottle blaster system.

    Get PDF
    A dishwasher works by using water pressure to operate the Spray Arms. There are different types of wash systems with the most common being two spray arms, a lower and middle arm. These two spray arms operate independently from each other and can be powered individually. In this particular wash system, the subsystem of interest is the Mid Spray Arm which is connected with the Bottle Blaster where both operate simultaneously. The Mid Spray Arm is used to clean the upper dishwasher rack while the Bottle Blaster is used to clean bottles, also in the upper rack. In order to have proper cleaning performance in the dishwasher, the Mid Spray Arm needs to rotate with at least 20 revolutions per minute (RPM). Since the Mid Spray Arm and Bottle Blaster are connected together, the flow rate requirement is 12 gallons per minute (GPM); which is higher than a system that doesn’t include a Bottle Blaster (approximately 8.5 GPM). In order to reduce the amount of water usage and flow rate, a new system was configured that will independently operate the Mid Spray Arm and Bottle Blaster. For that, three different designs were created and a Pugh Matrix was used to select the appropriate design. The selected design will operate using water pressure to block the Mid Spray Arm port or the Bottle Blaster port and is attached to the Main Conduit before the Mid Spray Arm. This new system reduced the water consumption of the entire dishwasher due to the fact that is able to operate with a smaller pump. The new system provides 8.53 GPM to the Mid Spray Arm and 6.48 GPM to the Bottle Blaster compared to 9.88 GPM and 7.32 GPM respectively with the current system. This new system has a better cleaning performance due to the increased in RPM’s, now 25 RPM, on the Mid Spray Arm. Also, since a smaller pump can be used the new pump price will be $12.38, which is approximately 17% less expensive than the current pump. Another advantage is the reduction in noise by approximately 11% from an initial 21.3 dBa pump output

    Model for Geological Risk Management in the Building and Infrastructure Processes

    Get PDF
    The geologic risks management is a process that requires to follow the tendencies of the new models of technological innovation. Nowadays it becomes necessary to elaborate an specific model for the management of the geologic risks, that is adapted to the peculiarities of the current development of the building and infrastructure systems; and allow the use of the current tools as the GIS, Wombs, Analysis Cost Benefit, etc., for the organization and the control of the knowledge management and final quality of the executed works. To model with the processes management could be an alternative form before this task. Proposing in this occasion a variant to negotiate from this perspective the management of geologic risks in the building and infrastructure processes.Keywords: Model, risks, management, geological hazards, process management, buildings, infrastructures

    Measuring Levels on Collectivism and Individualism with One Maya Volunteer

    Get PDF
    Measuring levels of collectivism and individualism among Maya living in the United States will help us understand, among other variables, their struggles, and the consequences of migrating to the most individualist nation on earth

    The intrinsic fluorescence of FAD and its application in analytical chemistry: a review

    Get PDF
    This review (with 106 references) mainly deals with the analytical applications of flavin-adenine dinucleotide (FAD) fluorescence. In the first section, the spectroscopic properties of this compound are reviewed at the light of his different acid-base, oxidation and structural forms; the chemical and spectroscopic properties of flavin mononucleotide (FMN) and other flavins will be also briefly discussed. The second section discusses how the properties of FAD fluorescence changes in flavoenzymes (FvEs), again considering the different chemical and structural forms; the glucose oxidase (GOx) and the choline oxidase (ChOx) cases will be commented. Since almost certainly the most reported analytical application of FAD fluorescence is as an auto-indicator in enzymatic methods catalysed by FvE oxidoreductases, it is important to know how the concentrations of the different forms of FAD changes along the reaction and, consequently, the fluorescence and the analytical signals. An approach to do this will be presented in section 3. The fourth part of the paper compiles the analytical applications which have been reported until now based in these fluorescence properties. Finally, some suggestions about tentative future research are also given

    Silvestre Galban a Juan Facundo Quiroga

    Get PDF
    Comunicando que se ha realizado matanza de ganado y remitiendo a los presuntos culpable

    Intercambio de correspondencia entre Silvestre Galban y Domingo Ocampo

    Get PDF
    Referencias a una operaciĂłn bancari

    Silvestre Galban al Juez Pedáneo Patricio Tello

    Get PDF
    Comunicando haber recibido orden del Coronel con respecto a la caballad

    Silbestre Galban a Juan Facundo Quiroga

    Get PDF
    Pidiendo que evite la salida de los bienes de Patricio Tello para San Juan y San Lui

    Silbestre Galván a Juan Facundo Quiroga

    Get PDF
    Asuntos relacionados con el reclutamiento y envĂ­o de tropas a Buenos Aire

    Silbestre Galván a Juan Facundo Quiroga

    Get PDF
    Reclama su presencia ante la elección del Dr. Alvarez y de Julián Carmona por la Junta de Representantes en calidad de diputados al Congreso y por las circunstancias difíciles de la lucha contra Brasil que exigen la organización de la milici
    • …
    corecore